000 | 02636cam a2200337 a 4500 | ||
---|---|---|---|
003 | EG-GiCUC | ||
005 | 20250223032340.0 | ||
008 | 190805s2019 ua dho f m 000 0 eng d | ||
040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
041 | 0 | _aeng | |
049 | _aDeposite | ||
097 | _aM.Sc | ||
099 | _aCai01.21.03.M.Sc.2019.Ba.V | ||
100 | 0 | _aBasma Osama Mohammed Galal Alsaadawy | |
245 | 1 | 0 |
_aValidity and reliability of smartphone use in measuring joint position sense in patients with knee osteoarthritis / _cBasma Osama Mohammed Galal Alsaadawy ; Supervised Aliaa Rehan Youssef , Eman Ahmed Abdelmoez |
246 | 1 | 5 | _aصلاحية وموثوقية الهاتف الذكي لقياس الاحساس بوضع المفصل في مرضى الالتهاب العضمي المفصلي للركبة |
260 |
_aCairo : _bBasma Osama Mohammed Galal Alsaadawy , _c2019 |
||
300 |
_a67 P. : _bcharts , facsimiles , photoghraphs ; _c25cm |
||
502 | _aThesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Musculoskeletal Disorders | ||
520 | _aBackground:Proprioception deficit is a risk factor for knee osteoarthritis (OA) progression.Thus, proper assessment and treatment of this deficit are important in the management of patients with OA. Recently, smartphone has been used in the assessment of musculoskeletal system.There are a few valid applications to measure proprioception of various joints, suggesting the promising use of smartphone as an alternative economic method to assess proprioception acuity in clinical settings. However, validation of proprioception assessment still needs further confirmation.Therefore, this study aimed at investigating the concurrent validity of using smartphone in assessing proprioception acuity in patients with knee OA. Methods:Thirty-two knees from 16 participants were assessed; 8 asymptomatic volunteers and 8 patients with bilateral OA. Proprioception acuity was measured in terms of passive joint position (JPS) simultaneously by the smartphone Goniometer pro application andthe Biodex System 3 Pro Isokinetic Dynamometer. Each participant had the angle of repositioning error measured during passive motion three times and the average was calculated and used for further statistical analyses | ||
530 | _aIssued also as CD | ||
653 | 4 | _aJoint position sense | |
653 | 4 | _aKnee osteoarthritis | |
653 | 4 | _aSmartphone | |
700 | 0 |
_aAliaa Rehan Youssef , _eSupervisor |
|
700 | 0 |
_aEman Ahmed Abdelmoez , _eSupervisor |
|
856 | _uhttp://172.23.153.220/th.pdf | ||
905 |
_aNazla _eRevisor |
||
905 |
_aShimaa _eCataloger |
||
942 |
_2ddc _cTH |
||
999 |
_c73292 _d73292 |