000 02900cam a2200313 a 4500
003 EG-GiCUC
008 191013s2018 ua do f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.09.M.Sc.2018.Al.E
100 0 _aAlaa Samir Fathy Elashkar
245 1 0 _aEffect of the crystallization process on the marginal and internal gaps of partially crystallized versus fully crystallized zirconium reinforced lithium silicate CAD/CAM crowns :
_bAn in-vitro study /
_cAlaa Samir Fathy Elashkar ; Supervised Adel Mohamed Eltannir , Maha Ahmed Taymour
246 1 5 _aاثر عملية التبلور على الثغرات الهامشية والداخلية في تيجان جزئية التبلور إزاء كاملة التبلور الليثيوم سيليكيت المعززة بالزركونيا CAD/CAM :
_bدراسة معملية
260 _aCairo :
_bAlaa Samir Fathy Elashkar ,
_c2018
300 _a110 P. :
_bcharts , photographs ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aStatement of the problem: The precision of fit of chair-side CAD-CAM Zirconia reinforced lithium silicate crowns is still under research and the effect of post milling protocol on the marginal adaptation is not yet clearly stated in literature. Purpose: The aim of this study was to evaluate the marginal adaptation of fully crystallized versus partially crystallized zirconia reinforced lithium silicate (ZLS) ceramic computer-aided design/computer-aided manufacturing (CAD/CAM) fabricated crowns using stereomicroscope. Materials and methods: A total of 16 ceramic zirconia reinforced lithium silicate crowns. They were divided into two groups according to the degree of crystallization. The marginal adaptation of the fully crystallized zirconia reinforced lithium silicate CELTRA DUO (Dentsply, Sirona, Germany), were compared with the partially crystallized zirconia reinforced lithium silicate VITA SUPRINITY (VITA Zahnfabrik,Germany) after its crystallization. The 16 crowns (n=8 each group) were fabricated using a chair side CAD-CAM system. The crowns and die/crown assembly were viewed under stereomicroscope. 36 measurements were made for each crown, 9 measurements on each surface. The vertical marginal gap was directly viewed and measured using stereomicroscope. Data were recorded and statistically analyzed using the t- test and Two-way ANOVA test. The significance level was set at P {u2264} 0.05
530 _aIssued also as CD
653 4 _aCeltra Duo
653 4 _aMarginal adaptation
653 4 _aVita Suprinity
700 0 _aAdel Mohamed Eltannir ,
_eSupervisor
700 0 _aMaha Ahmed Taymour ,
_eSupervisor
905 _aAsmaa
_eCataloger
905 _aNazla
_eRevisor
942 _2ddc
_cTH
999 _c74458
_d74458