000 02896cam a2200349 a 4500
003 EG-GiCUC
005 20250223032517.0
008 200121s2018 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.09.M.Sc.2018.Mo.E
100 0 _aMohamed Ahmed Abdelhameed
245 1 0 _aEvaluation of patient satisfaction and microbiological changes in injectable thermoplastic resin and conventional acrylic resin complete dentures :
_bA randomized clinical trial /
_cMohamed Ahmed Abdelhameed ; Supervised Amal Rekaby Taha , Azza Farahat Metwally , Reham Dewdar
246 1 5 _aتقييم رضاء المرضى والتغيرات الميكروبيولوجية لطقم كامل مصنوع من الاكريليك الحرارى القابل للحقن مقارنة الأكريليك التقليدى
260 _aCairo :
_bMohamed Ahmed Abdelhameed ,
_c2018
300 _a118 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aObjectives: The present study was conducted to compare between the polyamide thermoplastic resin and polymethyl methacrylate resin with respect to the patient satisfaction as a primary outcome and candidal adherence as a secondary outcome. Subjects and methods: In this randomized clinical trial, forty-eight completely edentulous patients were randomly classified into two groups of twenty-four patients each. Group (I) had received a complete denture made from a polyamide thermoplastic material complete denture. Group (II) had received complete denture made from polymethyl methacrylate. Patient satisfaction was evaluated using a questionnaire and candidal count was evaluated by collection of swabs cultured on Sabouraud{u2019}s agar gel plates. Results: There was no significant difference in mean Satisfaction between Group I and Group II at insertion or 1 month periods (p >0.05), However, there was a significant difference in mean Satisfaction between Group I and Group II in 3 months and 6 months periods (p < 0.05). The previously mentioned results revealed that there was no significant difference in mean CFU between Group I and Group II at insertion or 1 month or 3 months period (p >0.05) except in 6 months period where there was a significant difference in mean CFU between Group I and Group II (p < 0.05)
530 _aIssued also as CD
653 4 _aCandidal count
653 4 _aPatient satisfaction
653 4 _aPolyamide thermoplastic materia
700 0 _aAmal Rekaby Taha ,
_eSupervisor
700 0 _aAzza Farahat Metwally ,
_eSupervisor
700 0 _aReham Dewdar ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c76425
_d76425