000 03436cam a2200337 a 4500
003 EG-GiCUC
005 20250223032637.0
008 201128s2019 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.06.M.Sc.2019.Mo.E
100 0 _aMohamed Amr Elsayed Abdelrehim Hussein Labib
245 1 0 _aEvaluation of the accuracy of digital models obtained using intraoral and extraoral scanners versus gold standard plaster model :
_bDiagnostic accuracy study /
_cMohamed Amr Elsayed Abdelrehim Hussein Labib ; Supervised Khaled Hazem Attia , Amr Ragab Elbeialy
246 1 5 _aتقييم دقة التشخصية للنماذج الرقمية المستمدة من تقنية الرقمنة الداخل فموى و الخارج فموى :
_bمقارنة بالنماذج الجبسية المثالية
260 _aCairo :
_bMohamed Amr Elsayed Abdelrehim Hussein Labib ,
_c2019
300 _a111 P. :
_bcharts , facimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Orthodontics
520 _aDigital models are becoming the standard orthodontic record in many dental practices around the world. They have gained popularity in orthodontics due to their advantages over plaster in storing, retrieving, sharing of information, diagnosis and treatment planning cases. This is due to feasibility of the virtual environment which shortens the time required for each procedure. Digital models have been made from alginate impressions as well as with intra-oral scanners to prove their reliability and accuracy. Therefore, the main objective of this study was to relate dental measurements on 3-D models obtained through intraoral scanning and extra-oral scanning modalities and evaluate their diagnostic accuracy to the reference standard plaster replica in a sample of Egyptian population. Twenty-four adult male and female subjects of the Egyptian population were randomly selected for this study. Intra-oral scanning, extra-oral scanning of the plaster models obtained via alginate impression, extra-oral scanning of the plaster models obtained via rubber base impression, extra-oral scanning of the rubber base impression and extra-oral scanning of the alginate impression were done for all subjects. Linear dental measurements included intermolar width, interpremolar width, intercanine width, mesiodistal width of 1st permanent molar, 1st premolar, canine and central incisor and arch width. All data were collected, tabulated and subjected to statistical analysis. The results showed small differences between the plaster and digital models. The small differences could be appropriate for clinical use for the majority of parameters. Intra-observer reliability analysis for 14 out of the 16 measurements showed that all variables exhibited good to excellent reliability. The most accurate digitization technique was the 3Shape laboratory scanner of the cast of the alginate impression
530 _aIssued also as CD
653 4 _aDigital models
653 4 _aIntraoral and extraoral scanners versus
653 4 _aOrthodontics
700 0 _aAmr Ragab Elbeialy ,
_eSupervisor
700 0 _aKhaled Hazem Attia ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c78991
_d78991