000 03051cam a2200337 a 4500
003 EG-GiCUC
005 20250223032649.0
008 201228s2020 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.09.M.Sc.2020.Ay.F
100 0 _aAya Ibrahim Mohamed Yassin
245 1 0 _aFracture resistance of interim restoration constructed by 3D printing versus CAD/CAM technique /
_cAya Ibrahim Mohamed Yassin ; Supervised Gihan Abdelhady Elnaggar , Dina Magdy Elshehawy
246 1 5 _aمقاومة الكسر للأستعاضة المؤقتة باستخدام تقنية الطباعه ثلاثية الأبعاد مقابل تقنية الانطباع الرقمية :
_bدراسة معملية
260 _aCairo :
_bAya Ibrahim Mohamed Yassin ,
_c2020
300 _a112 P. :
_bcharts , facimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aAim: to assess the fracture resistance of interim restorations fabricated by 3D printing technique compared to milling technique. Methodology: Typodont model of maxillary 1st molar was preprared for full coverage crowns.The prepared model was digitally scanned by extraoral scanner. Duplication of master die into sixteen epoxy resin dies. Sixteen interim crowns were constructed by two techniques include: CAD/CAM technology using TelioCAD PMMA disc and 3D printing technology using Nextdent C&B resin material.The specimens were divided into 2 equal groups (n=8). All interim crowns were cemented on their corresponding resin dies using cementation loading device. All samples were subjected to thermal cycles(1250cycles,5-55c) and mechanical cycles (37,000cycles,50N). Using SEM to assess the surface topography for samples in both groups and EDX microanalysis was used to evaluate the elemental compositions with relative values expressed in wt% and K ratio.The specimens were loaded to failure in Newton (N) using universal testing machine. Stereomicroscope was used to investigate the fracture pattern. Data was statistically analyzed used Kolmogorov-Smirnov and Shapiro-Wilk tests & Student{u2019}s t tests (Ü = 0.05) and failure mode (%) by the Fisher exact test & chi2 test (p{u2264}0.05). Results: The mean ± SD values of fracture resistance were recorded for milled group (933.46 ±104.49 N) meanwhile the mean ± SD value recorded with printed group were (1226.48±48.33 N). It was found that printed group recorded statistically significant higher fracture resistance mean value than milled group
530 _aIssued also as CD
653 4 _aFracture resistance
653 4 _aInterim restoration constructed
653 4 _aThree Dimensional (3D)
700 0 _aDina Magdy Elshehawy ,
_eSupervisor
700 0 _aGihan Abdelhady Elnaggar ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c79370
_d79370