000 | 03096cam a2200337 a 4500 | ||
---|---|---|---|
003 | EG-GiCUC | ||
005 | 20250223032652.0 | ||
008 | 210104s2019 ua dho f m 000 0 eng d | ||
040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
041 | 0 | _aeng | |
049 | _aDeposite | ||
097 | _aM.Sc | ||
099 | _aCai01.09.09.M.Sc.2019.Ma.E | ||
100 | 0 | _aMahmoud Adel Shaaban | |
245 | 1 | 4 |
_aThe effect of platelet rich fibrin (PRF) versus xenograft in closed sinus lift with implant placement on implant stability in maxillary posterior area : _bRandomized clinical trial / _cMahmoud Adel Shaaban ; Supervised Ahmed Mohamed Fahmy , Nada Sherin Elkhourazaty |
246 | 1 | 5 |
_aتأثير استخدام الفيبرين الغنى بالصفائح الدموية مقارنة بشرائح العظم فى عمليات الرفع المغلق للجيوب الأنفية على ثبات الغرسة فى المنطقة الخلفية بالفك العلوي : _bتجربة سريرية عشوائية |
260 |
_aCairo : _bMahmoud Adel Shaaban , _c2019 |
||
300 |
_a68 P. : _bcharts , facimiles ; _c25cm |
||
502 | _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics | ||
520 | _aThe most common problem after extraction of upper posterior teeth are maxillary sinus Pneumatization with resorption of its underling alveolar ridge and decrease in bone quality in upper posterior region.The present study was conducted to evaluate the primary stability of implant in closed sinus lifting cases using PRF as a grafting material in comparison to xenograft using Ostell based on the concept of resonance frequency analysis in assessing primary stability.he sample of this study consisted of sixteen maxillary partially edentulous patients who were examined clinically and radiographically.The patients were chosen from the outpatient Dental Implant Clinic, Faculty of Dentistry, Cairo University based on the inclusion-exclusion criteria previously mentioned.Patients were divided in to two equal groups Group A: closed sinus lifting by Osteotome using PRF as grafting material with implant placement in 8 partially edentulous patients Group B: Closed sinus lifting by osteotome using xenograft as a grafting material with implant placement in 8 partially edentulous patients.After implant placement, Smart peg was placed on implant and Ostell is used to record ISQ. Implant stability was measured intraoperative and at week 2, 4, 6, 8 and 10 for both groups.The collected results were tabulated and statistically analyzed. The study results showed that there was no statistically significant difference between (PRF) and (Xenograft) groups in ISQ reading | ||
530 | _aIssued also as CD | ||
653 | 4 | _aMaxillary posterior area | |
653 | 4 | _aPlatelet rich fibrin (PRF) | |
653 | 4 | _aXenograft in closed sinus lift | |
700 | 0 |
_aAhmed Mohamed Fahmy , _eSupervisor |
|
700 | 0 |
_aNada Sherin Elkhourazaty , _eSupervisor |
|
856 | _uhttp://172.23.153.220/th.pdf | ||
905 |
_aNazla _eRevisor |
||
905 |
_aShimaa _eCataloger |
||
942 |
_2ddc _cTH |
||
999 |
_c79474 _d79474 |