000 | 03095cam a2200349 a 4500 | ||
---|---|---|---|
003 | EG-GiCUC | ||
005 | 20250223032709.0 | ||
008 | 210227s2020 ua do f m 000 0 eng d | ||
040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
041 | 0 | _aeng | |
049 | _aDeposite | ||
097 | _aM.Sc | ||
099 | _aCai01.09.09.M.Sc.2020.Ar.C | ||
100 | 0 | _aArsany Emil Amin Khellah | |
245 | 1 | 0 |
_aClinical & radiographic assessment of socket shield technique in maxillary esthetic zone with immediate temporization : _bA case series study / _cArsany Emil Amin Khellah ; Supervised Mohammed Khashaba , Nesrine Mohammad khairy , Mohamed Atef |
246 | 1 | 5 |
_aالتقييم السريرى والشعاعى لتقنية الدرع السنخى فى المنطقه التجميلية للفك العلوى مع التحميل الفورى المؤقت : _bدراسة سريرية تسلسلية |
260 |
_aCairo : _bArsany Emil Amin Khellah , _c2020 |
||
300 |
_a78 P. : _bcharts , facimiles ; _c25cm |
||
502 | _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics | ||
520 | _aAim: The study aimed to assess clinical implant stability & pink esthetic score in the socket shield technique with immediate temporization in the maxillary esthetic zone. Methodology: Fourteen patients were randomly selected from the outpatient clinic of the Implantology Department.They were treated with immediate implant placement with socket shield technique and immediate temporization in the maxillary anterior region. The patients were assigned to be treated using 30 titanium implants. Results: means no visual change of bone level from preoperative and post 6 months x- ray, ,mean PES immediately postoperative was 10.1+ 1.4 that increased to 11.6+1.4 six months postoperative the difference was statistically significant(P {u2264} 0.05) , mean stability immediately postoperative was 56.3+3.9 that increased to 69.5+4.7 six months postoperative the difference was statistically significant(P {u2264} 0.05) Conclusion: Socket shield technique with immediate temporization is a viable option for immediate replacement of teeth in the esthetic zone, overcoming dimension bone changes after extraction and soft tissue contour.The contact between the rough titanium surface and the tooth surface in immediate implant placement simultaneously with partial extraction therapy technique does not affect implant stability or osteointegration. Long term follows up studies are required to confirm the long term stability of the technique.The main factor in implant placement is the proper prosthetic position, either contact or not with the shield | ||
530 | _aIssued also as CD | ||
653 | 4 | _aClinical & radiographic | |
653 | 4 | _aMaxillary esthetic zone | |
653 | 4 | _aSocket shield technique | |
700 | 0 |
_aMohamed Atef , _eSupervisor |
|
700 | 0 |
_aMohammed Khashaba , _eSupervisor |
|
700 | 0 |
_aNesrine Mohammad khairy , _eSupervisor |
|
856 | _uhttp://172.23.153.220/th.pdf | ||
905 |
_aNazla _eRevisor |
||
905 |
_aShimaa _eCataloger |
||
942 |
_2ddc _cTH |
||
999 |
_c80025 _d80025 |