000 03185cam a2200337 a 4500
003 EG-GiCUC
005 20250223032815.0
008 210914s2021 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.12.11.M.Sc.2021.Mo.C
100 0 _aMohamed Gamal Abdelkader Hammad
245 1 0 _aComposite materials based on polymers, carbon and nanoparticles for enhancing some chemical reactions /
_cMohamed Gamal Abdelkader Hammad ; Supervised Nada Farouk Ahmed Atta , Yousef Mohamed Ahmed
246 1 5 _aمواد مركبة مرتكزة على البلمرات و الكربون و الحبيبات النانونية لتحسين بعض التفاعالت الكيميائية
260 _aCairo :
_bMohamed Gamal Abdelkader Hammad ,
_c2021
300 _a50 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Science - Department of Physical Chemistry
520 _aAnalyses of important biological species, environmental contaminants, and other important analytes are possible using electrochemical sensing. Among the numerous transduction methods, the electrochemical approach has gained the most focus due to their good sensitivity and high selectivity, accuracy, high dynamic range, lower cost, and simplicity. In this work, assaying uric acid in physiological fluid and Nitrite ion in water samples is achieved with high sensitivity and low detection limit. A simple and efficient electrochemical sensor is fabricated for electrochemical sensing of UA in presence of interfering species: epinephrine (Ep) and tyrosine (Ty). The sensor is fabricated by drop-casting a thin layer of CNTs followed by electrodeposition of two successive thin layers of poly(L-methionine) (PMT) and 18-crown-6 (CW) over a glassy carbon (GC) surface; GC/CNT/PMT/CW. Each of the sensor components' unique property contributes in synergism to the current signal enhancement. Voltammetry determination of UA in presence of Ep and Ty in human blood serum in the concentration ranges (0.04 to 40 oM), (0.04 to 40 oM), and (0.08 to 75 oM) is successfully achieved with low detection limits of 2.7 nM, 2.3 nM and 6.3 nM, respectively. Practical application of the GC/CNT/PMT/CWsensor is efficiently assessed in human serum samples for UA determination with acceptable recoveries, excellent anti- interference ability and long-term stability. Electrochemical determination of nitrite in real water samples is achieved using a simple and efficient electrochemical sensor.The sensor is fabricated by electrodeposition of a thin layer of poly(3,4-ethylenedioxythiophene) sandwiched by drop- casting two thin layers of CNTs and iron oxide nanoparticles (Fe3O4) over a GC electrode surface
530 _aIssued also as CD
653 4 _a18-crown{u2013}6
653 4 _aCarbon nanotubes
653 4 _aPoly L-methionine
700 0 _aNada Farouk Ahmed Atta ,
_eSupervisor
700 0 _aYousef Mohamed Ahmed ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c82131
_d82131