000 03397cam a2200349 a 4500
003 EG-GiCUC
005 20250223032819.0
008 210919s2010 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.02.M.Sc.2010.Sa.A
100 0 _aSamar Hassan Elkassas
245 1 0 _aAdaptability and interface assessment of thermafil obturator, soft-core system and continuous wave of obturation using a split tooth model :
_bAn in vitro study /
_cSamar Hassan Elkassas ; Supervised Maged Negm , Medhat Abdelrahman Kataya , Mohsen Nour Eldeen
246 1 5 _aتقييم السطح الفاصل و تطابق نظام الثيرمافيل: ونظام اللب الطرى: و نظام الموجة المستمرة بإستخدام نموذج السن المنشقة :
_bدراسة معملية
260 _aCairo :
_bSamar Hassan Elkassas ,
_c2010
300 _a102 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Endodontics
520 _aThe aim of this study was to evaluate the adaptation of the obturation materials to the root canal walls, and its ability to conform to different canal irregularities in three techniques of obturation; namely: Thermafil (core carrier technique), Soft-Core system (core carrier technique) and System B (continuous wave of obturation). A recently extracted human maxillary central incisor with straight, completely formed root was used in this study. A split-tooth model was constructed and four alignment holes were drilled perpendicular to the long axis of the tooth, apical to the level of cementoenamel junction.These holes were drilled on the facial side of the root, and the other two on the palatal side.The block with the tooth was then longitudinally, buccolingually sectioned through the center of the root canal using a low-speed diamond disc. The two halves of the block could then be re-approximated and secured with four nuts and bolts placed in the alignment holes. Straight-line endodontic access preparation to the root canal was then made with a size #6 round bur in a low speed hand piece. The working length was established by visually placing the tip of a size #10 K-Flexofile 1 mm short of the anatomical root apex on one of the halves. The two halves of the root were reapproximated and secured with the four alignment nuts and bolts. The root canal was cleaned and shaped using K- Flexofiles, with the standard step-back preparation, up to size #60 master apical file. Saline irrigation was used throughout the whole instrumentation phase.Canal irregularities were artificially produced with size #1 round bur, making three shallow depressions (less than 0.5 deep) on the distal side of the canal at 1, 3, and 5 mm from the working length, and two similar depressions on the mesial half at 2 and 4 mm from the working length
530 _aIssued also as CD
653 4 _aSoft-core system
653 4 _aSplit tooth model
653 4 _aThermafil obturator
700 0 _aMaged Negm ,
_eSupervisor
700 0 _aMedhat Abd El Rahman Kataya ,
_eSupervisor
700 0 _aMohsen Nour Eldeen ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c82268
_d82268