000 03537cam a2200349 a 4500
003 EG-GiCUC
005 20250223032843.0
008 211106s2021 ua dho f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aPh.D
099 _aCai01.21.04.Ph.D.2021.Me.M
100 0 _aMenna Allah Youssef Mohammed
245 1 0 _aMagnetic field versus interferntial current on abdominal fat thickness in postnatal women /
_cMenna Allah Youssef Mohammed ; Supervised Khadiga Sayed Abdelaziz , Mohamed Ahmed Mohamed Awad , Amir Arabi Gabr
246 1 5 _aالمجال المغناطيسى مقابل التيار المتداخل على سمك دهون البطن لدى السيدات بعد الولادة
260 _aCairo :
_bMenna Allah Youssef Mohammed ,
_c2021
300 _a104 P. :
_bcharts , facsimiles , phoroghraphs ;
_c25cm
502 _aThesis (Ph.D.) - Cairo University - Faculty of Physical Therapy - Department of Physical Therapy for Gynecology and Obstetrics
520 _aThis study was conducted to compare the effect of pulsed electromagnetic field versus interferential current on abdominal fat thickness in postnatal women. This study included sixty obese postnatal womenselected randomly from Kasr El Ainy University Hospital in Cairo. This study enlisted the participation of multipara women. Their ages ranged between 30 and 40 years. The BMI of the participants ranged between 30 to 39.9 kg/m2. Their births were vaginal deliveries and caesarian sections. They were chosen at least two years after the previous delivery. During the study, they did not use any fat-burning drugs. Women with active kidney or hepatic disease, heart disease, diabetes mellitus, hypertension, pregnancy, pacemaker, psychosis, thyroid disease, central nervous system dysfunction, mental retardation and cancer are excluded from the study. Design of the study wastwo groups{u2019} pre-test and post-test experimental design.They were divided randomly into two groups (A&B) equal in number. Group A included thirty postnatal women treated with pulsed electromagnetic field on the abdomen. Each session was about 20 minutes, 3 times per week, for 4 weeks. Group B included thirty postnatal women treated with the interferential current on the abdomen. Each session was about 20 minutes, 3 times per week, for 4 weeks. BMI was evaluated by weight and height scale, waist circumference (WC) was evaluated by tape measurement, abdominal skin fold thickness was evaluated by skin fold caliper and blood lipids profile (total cholesterol, triglyceride, low density lipoprotein, Very low density lipoprotein and high density lipoprotein) were evaluated for both groups (A&B) before and after treatment. Results of this study showed that; within groups, there were significant reduction of BMI, WC, abdominal skin fold thickness and blood lipids profile (total cholesterol, triglyceride, low density lipoprotein and VLDL) and significant increase in high density lipoprotein in both groups (A&B) post treatment in compare to pre treatment
530 _aIssued also as CD
653 4 _aAbdominal Fat Thickness
653 4 _aInterferential current
653 4 _aPulsed electromagnetic field
700 0 _aAmir Arabi Gabr ,
_eSupervisor
700 0 _aKhadiga Sayed Abdelaziz ,
_eSupervisor
700 0 _aMohamed Ahmed Mohamed Awad ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c83007
_d83007