000 03140cam a2200337 a 4500
003 EG-GiCUC
005 20250223032844.0
008 211108s2021 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.09.M.Sc.2021.Ha.E
100 0 _aHaytham Mohammed Talaat
245 1 0 _aEvaluation of retention of partial denture made of injected molded PEEK frameworkversus colbalt chromium framework in mandibular kennedy class I edentulous cases :
_bRandomized clinical trail /
_cHaytham Mohammed Talaat ; Supervised Amal Fathy Kaddah , Nada Sherin Elkharazaty
246 1 5 _aفى حالات كنيدى التقسيم الاول cobalt chromium و الثانى من مادة PEEK تقييم الفارق فى قوة الاستبقاء بين نوعين من التركيبات المتحركة الاول مصنع من الصبة المحقونة من مادة :
_bدراسة سريرية عشوائية
260 _aCairo :
_bHaytham Mohammed Talaat ,
_c2021
300 _a100 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aAim: The objective of this study was to evaluate the retentive forces of PEEK RPD with PEEK clasps in comparison to Cobalt-Chrome (Co-Cr) RPD with (Co-Cr) clasps during attachment/detachment cycles on abutment teeth in mandibular kennedy class I free end saddle edentulous cases using digital force meter device. Methodology: Mandibular Kennedy class I patients with natural abutments teeth (last standing 2nd premolars) bilaterally were selected for the trial. Abutments of group I Patients were prepared for receiving metal framework removable partial dentures with acrylic teeth and these frameworks were fabricated by conventional casting technique while the abutments of group II patients were prepared to receive PEEK framework removable partial denture with acrylic teeth which were fabricated by injection molding technique. Digital force meter device was used to measure retentive forces of PEEK RPD with peek clasps in comparison to Cobalt-Chrome (Co-Cr) RPD with (Co-Cr) clasps during attachment/detachment cycles. Results: In group I (Control group), there was a statistically significant decrease in retention between 0 month, 1 month and 3 months. For group II (Intervention group) , there was a statistically insignificant difference in retention between 0 month and 1 month, and statistically significant increase in retention between 1 month and 3 months.Comparing the two groups together, there was statistically significant difference between them where Co-Cr RPD offered higher degree of retention in all periods of followup
530 _aIssued also as CD
653 4 _aColbalt chromium
653 4 _aKennedy class
653 4 _aPEEK
700 0 _aAmal Fathy Kaddah ,
_eSupervisor
700 0 _aNada Sherin Elkharazaty ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c83044
_d83044