000 03163cam a2200337 a 4500
003 EG-GiCUC
005 20250223032901.0
008 211219s2021 ua dh f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aPh.D
099 _aCai01.12.11.Ph.D.2021.As.E
100 0 _aAsmaa Reda Mohamed Elgohary
245 1 0 _aElectrochemical determination of some drugs, biological , and hazardous compounds at different modified electrodes /
_cAsmaa Reda M. Elgohary ; Supervised Soha Ali Abdelgawad , Afaf Abdelrazik Osman
246 1 5 _aتعيين كهروكيميائى لبعض الأدوية والمركبات البيولوجية والخطرة على الأقطاب المعدلة المختلفة
260 _aCairo :
_bAsmaa Reda Mohamed Elgohary ,
_c2021
300 _a251 P. :
_bcharts , facsimiles ;
_c25cm
502 _aThesis (Ph.D.) - Cairo University - Faculty of Science - Department of Physical Chemistry
520 _aDesigned modified electrodes were fabricated for determination of drugs, biological, and hazardous compounds. For drugs determination, GC/Gr/CNT-HQ/Fe-Ni sensor was fabricated based on layer-by-layer modification of a glassy carbon electrode (GC) surface with graphene (Gr), carbon nanotubes mixed with hydroquinone (CNT-HQ), and iron nickel alloy (Fe-Ni) for electrochemical determination of linezolid and meropenem in human blood serum. Another sensor CNT-Aunano-TU was fabricated by one-pot preparation of thiourea self-assembled monolayers (TU-SAMs) over gold nanoparticles mixed with carbon nanotubes for concurrent determination of dobutamine, paracetamol, amlodipine, and daclatasvir drugs. For biological compounds determination, GC/CNT/PHQ/CE and GC/ILC/(CNT-Fe-Ni) sensors were fabricated for simultaneous determination of levodopa, uric acid, and tyrosine, and for hydrogen peroxide in human blood serum samples, respectively. For hazardous compounds determination, GC/CNT/PHQ/CE sensor based on poly hydroquinone (PHQ) and crown ether (CE), and CNT-Aunano-TU sensor based on TU-SAMs were fabricated for concurrent determination of hydroquinone, catechol, and resorcinol, and for hydroquinone, catechol, phenol, and pnitrophenol, respectively in real water samples. Other sensors as GC/(CNT-Sr₂PdAuO₃) based on perovskite (Sr₂PdAuO₃), and GC/CNT/NF/CW/Aunano based on nafion (NF), crown ether (CW) and Aunano were fabricated for determination of hydrazine hydrate (HH) in real water samples. Low detection limits, excellent interference resistance, good reproducibility and perfect storage stability were the features of the modified sensors. Acceptable recoveries were obtained for practical applications of the studied sensors in real samples for determination of the above-mentioned compounds
530 _aIssued also as CD
653 4 _aCarbon nanotubes
653 4 _aGraphene
653 4 _aSensor
700 0 _aAfaf Abdelrazik Osman ,
_eSupervisor
700 0 _aSoha Ali Abdelgawad ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c83606
_d83606