000 | 03171cam a2200337 a 4500 | ||
---|---|---|---|
003 | EG-GiCUC | ||
005 | 20250223032902.0 | ||
008 | 211220s2021 ua dh f m 000 0 eng d | ||
040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
041 | 0 | _aeng | |
049 | _aDeposite | ||
097 | _aM.Sc | ||
099 | _aCai01.09.09.M.Sc.2021.Ba.F | ||
100 | 0 | _aBasma Osama Abbas Ghonim | |
245 | 1 | 0 |
_aFracture resistance of pressed zirconia reinforced lithium silicate crowns versus pressed lithium disilicate crowns under thermo- mechanical cycling : _bAn in vitro study / _cBasma Osama Abbas Ghonim ; Supervised Gihan Abdelhady Elnagar, Dina Magdy Elshehawi |
246 | 1 | 5 |
_aمقاومة الكسر للتيجان المصنوعة من الليثيوم سليكات المقوي بالزركونيا المضغوط مقابل التيجان المصنوعة من الليثيوم دايسليكات المضغوط عند تعرضهم للضغط الحرارى الدورى : _bدراسة معملية |
260 |
_aCairo : _bBasma Osama Abbas Ghonim , _c2021 |
||
300 |
_a109 P. : _bcharts , facsimiles ; _c25cm |
||
502 | _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics | ||
520 | _aAim: The present study was conducted to assess the fracture resistance of zirconia reinforced lithium silicate all ceramic material 2Celtra Press3 compared to lithium disilicate one 2IPS e-max Press3 under simulated oral conditions (thermal cycling and cyclic loading). Methodology : Fourteen ceramic crowns were fabricated on epoxy dies which were duplicated from stainless steel master die and divided into two equal groups (n=7) according to the material of construction; Group A: Crowns fabricated with IPS e-max Press material and Group B: Crowns fabricated with Celtra Press material.The crowns were then cemented onto their corresponding dies using with a self-adhesive resin cement (Calibra Universal) and subjected to thermocycling and cyclic loading to simulate the clinical conditions.Then they were loaded to fractur in a universal testing machine.The results were tabulated and statistically analyzed using Kolmogorov-Smirnov and Shapiro-Wilk tests. Student t-test used to compare mean values.The significance level was set at P{u2264} 0.05 and 95% Confidence interval. Statistical analysis was performed using Graph Pad Instat (Graph Pad, Inc.) software for windows Results: The mean ± SD values of fracture resistance were recorded for lithium Disilicate group (1706.01 ±154.32 N) meanwhile the mean ± SD value recorded with celtra group were (1550.67±196.71 N). It was found that e.max group recorded statistically non-significant higher fracture resistance mean value than celtra group as indicated by t-test (t=1.5, P=0.1590 > 0.05) | ||
530 | _aIssued also as CD | ||
653 | 4 | _aLithium disilicate | |
653 | 4 | _aThermal cycling | |
653 | 4 | _aZirconia reinforced lithium silicate | |
700 | 0 |
_aDina Magdy Elshehawi , _eSupervisor |
|
700 | 0 |
_aGihan Abdelhady Elnagar , _eSupervisor |
|
856 | _uhttp://172.23.153.220/th.pdf | ||
905 |
_aNazla _eRevisor |
||
905 |
_aShimaa _eCataloger |
||
942 |
_2ddc _cTH |
||
999 |
_c83623 _d83623 |