000 | 02933nam a2200349 a 4500 | ||
---|---|---|---|
003 | EG-GiCUC | ||
005 | 20250223032927.0 | ||
008 | 220308s2021 ua dh f m 000 0 eng d | ||
040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
041 | 0 | _aeng | |
049 | _aDeposite | ||
097 | _aM.Sc | ||
099 | _aCai01.09.09.M.Sc.2021.Em.P | ||
100 | 0 | _aEman Reda Abdalmouty | |
245 | 1 | 0 |
_aPredictability of teeth positions during complete denture fabrication using rapid prototyping technology compared to conventional fabrication method : _ban in vitro study / _cEman Reda Abdalmouty ; Supervised Ashraf Abdelmoneam Amer , Reham Bassuni Osman |
246 | 1 | 5 |
_aتوقعية مواضع الاسنان خلال تصنيع الطقم الكامل باستخدام تقنية التصنيع السريع مقارنة بالطريقة التقليدية للتصنيع : _bدراسة معملية |
260 |
_aCairo : _bEman Reda Abdalmouty , _c2021 |
||
300 |
_a129 P. : _bcharts , facsimiles ; _c25cm |
||
502 | _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics | ||
520 | _aAim: The purpose of this study was to compare the predictability of teeth positions during complete dentures fabrication through rapid prototyping technology and conventional fabrication method. Methodology : 12 dentures (6 upper and 6 lower) were fabricated using Liquid Crystal Display (LCD) rapid prototyping technology. The same models were used to fabricate another 12 dentures (6 upper and 6 lower) by the conventional compression flask technique. A structured light scanner was used to digitize the trial denture base of the compression dentures group just before processing, as well as the fabricated dentures by LCD technique.The pre-processing and post-processing scan files of each denture were superimposed using 3D-surface matching software. Measurements were made at 30 locations, allowing evaluation of denture tooth movement in occlusal direction.The use of mean and standard error values was used to assess occlusal accuracy. Data were explored for normality using Kolmogorov-Smirnov and Shapiro-Wilk tests, data showed parametric (normal) distribution. Paired sample t-test was used to compare the results between two groups in related samples. (a=.05). Results: The results showed higher mean value for occlusal teeth movement in the conventional group compared to the rapid prototyping counterpart. There was a statistically significant difference between two groups where (P<0.001) | ||
530 | _aIssued also as CD | ||
650 | 0 | _aProsthodontics Dontics | |
653 | _aFabrication method | ||
653 | _aPrototyping technology | ||
653 | _aTeeth positions during | ||
700 | 0 |
_aAshraf Abdelmoneam Amer , _eSupervisor |
|
700 | 0 |
_aReham Bassuni Osman , _eSupervisor |
|
856 | _uhttp://172.23.153.220/th.pdf | ||
905 |
_aShimaa _eCataloger |
||
905 | _eRevisor | ||
942 |
_2ddc _cTH |
||
999 |
_c84431 _d84431 |