Image from OpenLibrary

Kinovea software versus digital goniometer in measurement range of motion among school children / by John Fam Habib Atalla ; Supervisors Prof. Dr. Khaled Ahmed Olama, Prof. Dr. Khaled Ahmed Mamdouh, Dr. Amira Fathy Ibrahim.

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2025Description: 65 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • برنامج كينوفا مقابل مقياس الزوايا الرقمية في قياس مدي الحركة بين أطفال المدارس [Added title page title]
Subject(s): DDC classification:
  • 615.82
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (Ph.D)-Cairo University, 2025. Summary: Background: Measurement of joint range of motion (ROM) in static and dynamic, passive and active human movements is an essential skill in musculoskeletal assessments commonly performed by physiotherapists. Traditional ROM assessment can be obtained using goniometers or inclinometers. Kinovea is a versatile and user- friendly software application that has gained popularity in measuring and analyzing ROM. Aim: To measure ROM of elbow and knee joints among school children using digital goniometer and Kinovea software then compare the results of both measurements. Methods: This cross-sectional comparative study included 100 normal healthy children of both sexes recruited from different preparatory and secondary schools at Giza Governorate, Egypt. Digital medical scale was used for measuring body weight, height and calculating BMI on scale screen. Baseline digital goniometer and Kinovea Computer software were used to measure ROM of knee and elbow. The mean value of BMI (kg/m2) was 21.86 ±1.67kg/m2 with minimum value 18.70 and maximum value 24.80. The number (percentage) of gender distribution categories for children were 54 (54.00%) males and 46 (46.00%) females. Results: The statistical analysis revealed no significant statistical difference (P>0.05) in elbow flexion, elbow extension, knee flexion and knee extension by the both methods. There was high internal consistency and high Intra-class Correlation Coefficient of Kinovea software in measuring elbow flexion, extension, knee flexion and extension (p=0.001). Conclusion: As there was no difference between both methods in measuring ROM in knee and elbow, it is concluded that Kinovea has the ability to provide accurate knee and elbow ROM measurements. Kinovea software has high internal consistency and intra-rater reliability. It is a non-invasive, easy to use and cost-effective, tool that is coping with recent technological advancement making it particularly suitable for pediatric populations, where cooperation and comfort are essential. Summary: الخلفية:يُعَدّ قياس مدى حركة المفاصلفي الحركات الساكنة والديناميكية، السلبية والإيجابية، مهارة أساسية في التقييمات العضلية الهيكلية التي يُجريها أخصائيو العلاج الطبيعي بشكل شائع. يمكن الحصول على القياس التقليدي لمدى الحركة باستخدام أجهزة الجونيوميتر أو الميلوميتر. يُعتبر برنامج كينوفياتطبيقاً متعدد الاستخدامات وسهل التعامل، وقد اكتسب شعبية متزايدة في قياس وتحليل مدى الحركة. الهدف:قياس مدى حركة مفصلي المرفق والركبة لدى أطفال المدارس باستخدام الجونيوميتر الرقمي وبرنامجكينوفيا، ثم مقارنة نتائج القياسين. المنهجية:تضمنت هذه الدراسة المقطعية المقارنة 100 طفل سليم من كلا الجنسين، جرى اختيارهم من مدارس إعدادية وثانوية مختلفة بمحافظة الجيزة، مصر. استُخدم الميزان الطبي الرقمي لقياس الوزن والطول وحساب مؤشر كتلة الجسممباشرة على شاشة الميزان. كما استُخدم كل من الجونيوميتر الرقمي وبرنامجكينوفياالحاسوبي لقياس مدى حركة الركبة والمرفق. النتائج:بلغ متوسط قيمة مؤشر كتلة الجسم (كغ/م²) 21.86 ± 1.67 كغ/م²، بحد أدنى 18.70 وحد أقصى 24.80. أما التوزيع الجنسي للأطفال فكان 54 (54.00%) ذكراً و46 (46.00%) أنثى. أظهر التحليل الإحصائي عدم وجود فروق ذات دلالة إحصائية (P>0.05) في قياسات ثني المرفق، بسط المرفق، ثني الركبة، وبسط الركبة بين الطريقتين. كما أظهر برنامجكينوفيا اتساقاً داخلياً مرتفعاً ومعامل ارتباط داخلي عالياً في قياس ثني وبسط المرفق وثني وبسط الركبة (p=0.001). الاستنتاج:نظراً لعدم وجود اختلاف بين الطريقتين في قياس مدى حركة مفصلي الركبة والمرفق، خلصت الدراسة إلى أن برنامجكينوفيا يمتلك القدرة على تقديم قياسات دقيقة لمدى حركة الركبة والمرفق. يتميز البرنامج باتساق داخلي مرتفع وموثوقية عالية بين المقيمين، إضافةً إلى كونه أداة غير تداخلية، سهلة الاستخدام وذات تكلفة منخفضة، مما يجعله متوافقاً مع التطورات التكنولوجية الحديثة، وخصوصاً مناسباً لفئة الأطفال حيث يُعَدّ التعاون والراحة أمرين أساسيين.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.21.06.Ph.D.2025.Jo.K (Browse shelf(Opens below)) Not for loan 01010110093797000

Thesis (Ph.D)-Cairo University, 2025.

Bibliography: pages 56-63.

Background: Measurement of joint range of motion (ROM) in static and dynamic,
passive and active human movements is an essential skill in musculoskeletal
assessments commonly performed by physiotherapists. Traditional ROM assessment
can be obtained using goniometers or inclinometers. Kinovea is a versatile and user-
friendly software application that has gained popularity in measuring and analyzing
ROM.
Aim: To measure ROM of elbow and knee joints among school children using digital
goniometer and Kinovea software then compare the results of both measurements.
Methods: This cross-sectional comparative study included 100 normal healthy children
of both sexes recruited from different preparatory and secondary schools at Giza
Governorate, Egypt. Digital medical scale was used for measuring body weight, height
and calculating BMI on scale screen. Baseline digital goniometer and Kinovea
Computer software were used to measure ROM of knee and elbow. The mean value of
BMI (kg/m2) was 21.86 ±1.67kg/m2 with minimum value 18.70 and maximum value
24.80. The number (percentage) of gender distribution categories for children were 54
(54.00%) males and 46 (46.00%) females.
Results: The statistical analysis revealed no significant statistical difference (P>0.05)
in elbow flexion, elbow extension, knee flexion and knee extension by the both
methods. There was high internal consistency and high Intra-class Correlation
Coefficient of Kinovea software in measuring elbow flexion, extension, knee flexion
and extension (p=0.001).
Conclusion: As there was no difference between both methods in measuring ROM in
knee and elbow, it is concluded that Kinovea has the ability to provide accurate knee
and elbow ROM measurements. Kinovea software has high internal consistency and
intra-rater reliability. It is a non-invasive, easy to use and cost-effective, tool that is
coping with recent technological advancement making it particularly suitable for
pediatric populations, where cooperation and comfort are essential.

الخلفية:يُعَدّ قياس مدى حركة المفاصلفي الحركات الساكنة والديناميكية، السلبية والإيجابية، مهارة أساسية في التقييمات العضلية الهيكلية التي يُجريها أخصائيو العلاج الطبيعي بشكل شائع. يمكن الحصول على القياس التقليدي لمدى الحركة باستخدام أجهزة الجونيوميتر أو الميلوميتر. يُعتبر برنامج كينوفياتطبيقاً متعدد الاستخدامات وسهل التعامل، وقد اكتسب شعبية متزايدة في قياس وتحليل مدى الحركة.
الهدف:قياس مدى حركة مفصلي المرفق والركبة لدى أطفال المدارس باستخدام الجونيوميتر الرقمي وبرنامجكينوفيا، ثم مقارنة نتائج القياسين.
المنهجية:تضمنت هذه الدراسة المقطعية المقارنة 100 طفل سليم من كلا الجنسين، جرى اختيارهم من مدارس إعدادية وثانوية مختلفة بمحافظة الجيزة، مصر. استُخدم الميزان الطبي الرقمي لقياس الوزن والطول وحساب مؤشر كتلة الجسممباشرة على شاشة الميزان. كما استُخدم كل من الجونيوميتر الرقمي وبرنامجكينوفياالحاسوبي لقياس مدى حركة الركبة والمرفق.
النتائج:بلغ متوسط قيمة مؤشر كتلة الجسم (كغ/م²) 21.86 ± 1.67 كغ/م²، بحد أدنى 18.70 وحد أقصى 24.80. أما التوزيع الجنسي للأطفال فكان 54 (54.00%) ذكراً و46 (46.00%) أنثى. أظهر التحليل الإحصائي عدم وجود فروق ذات دلالة إحصائية (P>0.05) في قياسات ثني المرفق، بسط المرفق، ثني الركبة، وبسط الركبة بين الطريقتين. كما أظهر برنامجكينوفيا اتساقاً داخلياً مرتفعاً ومعامل ارتباط داخلي عالياً في قياس ثني وبسط المرفق وثني وبسط الركبة (p=0.001).
الاستنتاج:نظراً لعدم وجود اختلاف بين الطريقتين في قياس مدى حركة مفصلي الركبة والمرفق، خلصت الدراسة إلى أن برنامجكينوفيا يمتلك القدرة على تقديم قياسات دقيقة لمدى حركة الركبة والمرفق. يتميز البرنامج باتساق داخلي مرتفع وموثوقية عالية بين المقيمين، إضافةً إلى كونه أداة غير تداخلية، سهلة الاستخدام وذات تكلفة منخفضة، مما يجعله متوافقاً مع التطورات التكنولوجية الحديثة، وخصوصاً مناسباً لفئة الأطفال حيث يُعَدّ التعاون والراحة أمرين أساسيين.

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library