Passive fit of cad\cam implant supported metal frameworks designed based on virtual versus actual implant position : A pilot in-vitro study /
Mohamed El-Sayed Mohamed Kamel,
Passive fit of cad\cam implant supported metal frameworks designed based on virtual versus actual implant position : A pilot in-vitro study / تقييم التوافق السلبى للهياكل المصممة والمصنعه بالكمبيوتر ومدعومة بزراعات على وضعها الفعلى مقارنه بهياكل مدعومة بزراعات على وضعها المخطط له : دراسة معملية / By Mohamed El-Sayed Mohamed Kamel; Supervisors Prof. Dr. Iman Abdel Wahab Radi, Dr. Mohamed Amr El Khashab. - 119 pages : illustrations ; 25 cm. + CD.
Thesis (M.Sc.)-Cairo University, 2023.
Bibliography: pages 109-117.
Aim: To evaluate the passive fit of CAD/CAM 3 units implant supported frameworks that are constructed before and after implant placement in Kennedy Class I models.
Methodology: A sample of 5 Kennedy class I models, 2 with thin ridges and 3 with normal ridges, were restored by 20 frameworks bilaterally. 10 based on actual (group A) and 10 based on virtual (group V) implant positions. The models were imaged using cone beam computed tomography and scanned using an intraoral scanner .The STL (Standard Tessellation Language files) and the DICOM (Digital Imaging and Communications in Medicine) files were registered on a 3D planning software. A CAD/CAM surgical guide was planned, resin printed and used for installing the 6 implants bilaterally. In group V, the framework was designed based on the virtual scan bodies and virtual multi-unit abutments, while in group A intra-oral scanning of the model after attaching the scan bodies was necessary. Frameworks of both groups were milled and tested for passive fit using 8 tests. Fisher’s Exact test was used to compare between the two groups and the subgroups of the casts. The significance level was set at P ≤ 0.05. Results: No statistical significant difference in the passive fit of group V and group A frameworks was found (p-value=.044, OR=2.667). Regarding ridge form, no statistically significant difference was found between normal and thin ridges, whether in group V or A (P-value =.100).
Conclusion: Within the limitations of this study, the following can be concluded: In free end saddle cases, CAD\CAM 3-unit implant-supported frameworks designed and fabricated based on virtual implant positions have less chances of passive fit than those designed on actual ones. Also, ridge form affects the passive fit of the frameworks designed based on virtual implant positions هذه دراسة تقارن بين التوافق السلبي لالأطر المصممة والمصنعة وفقًا لاماكن الزرع الفعلية, و تلك التي تم صنعها وفقًا لاماكن الزرع الافتراضية.
في هذه الدراسة ، تم تصميم قالب يمثل تصنيف كينيدي من الفئة الأولى مطبوع بتقنية ثلاثي الأبعاد تم مسحه ضوئيًا باستخدام ماسح ضوئي داخل الفم لتلقي 3 غرسات ثنائية في كل جانب باستخدام الدليل الجراحي . سيتم تعويض كل جانب بواسطة 3 وحدات من إطار الكوبالت الكروم. سيتم تصميم أحد هذه الأطر بشكل كامل وبناؤه افتراضيًا ومثبتًا في دعامات متعددة الوحدات. على الجانب الآخر ، سيتم إرفاق أجسام المسح بالزرعات ومسحها ضوئيًا باستخدام ماسح ضوئي داخل الفم. سيتم تنفيذ التصميم وتصنيعه للحصول على 3 إطارات وحدات مثبتة ببراغي في دعامات متعددة الوحدات. يتم قياس التوافق السلبي باستخدام الاختبارات عدة وهي: اختبار برغي واحد و استقرار التركيبة و انزلاق الخيط الطبي واختبار مقاومة المسمار وتقييم شعاعي والوسائل الكاشفى للضغط. اختبار برغي واحد هو شد مسمار واحد ، تستلزم الخطوة الأولى تشديد دعامة واحدة بعيدة إلى الإطار وتقييم أي عدم متطابق مابين التركيبة و الزرعات مع ضغط الإصبع والتكبير يُظهر اختبار مقاومة المسمار أي حالات غير ملائمة تم اكتشافها عند الشد خارج نقطة المعايرة و هذه تشير إلى أن التوافق السلبي لللهيكل غير كافٍ عندما يتم نصف دورة للمسمار الموجود داخل الغرسة. يوفر التقييم الجوهري الراديوي اختبارا أكثر دقة لأي أخطاء في التركيب تقع بين الغرسات وواجهة الأطر حيث يكون وضع الهوامش الفرعية اللثوية أمرًا مضمونًا أظهرت النتائج أن انه لا اختلاف جوهري احصائيا للتوافق السلبي لالأطر التي تم تصميمها وإنشاؤها وفقًا لمواقع الزرع الفعلية تم تركيبها و تلك التي تم إنشاؤها وفقًا لمواقع الزرع الافتراضية او اختلاف علي حسب شكل العظم.
Text in English and abstract in English.
Implant surgery
CAD\CAM virtual actual guided implant surgery frameworks
617.605
Passive fit of cad\cam implant supported metal frameworks designed based on virtual versus actual implant position : A pilot in-vitro study / تقييم التوافق السلبى للهياكل المصممة والمصنعه بالكمبيوتر ومدعومة بزراعات على وضعها الفعلى مقارنه بهياكل مدعومة بزراعات على وضعها المخطط له : دراسة معملية / By Mohamed El-Sayed Mohamed Kamel; Supervisors Prof. Dr. Iman Abdel Wahab Radi, Dr. Mohamed Amr El Khashab. - 119 pages : illustrations ; 25 cm. + CD.
Thesis (M.Sc.)-Cairo University, 2023.
Bibliography: pages 109-117.
Aim: To evaluate the passive fit of CAD/CAM 3 units implant supported frameworks that are constructed before and after implant placement in Kennedy Class I models.
Methodology: A sample of 5 Kennedy class I models, 2 with thin ridges and 3 with normal ridges, were restored by 20 frameworks bilaterally. 10 based on actual (group A) and 10 based on virtual (group V) implant positions. The models were imaged using cone beam computed tomography and scanned using an intraoral scanner .The STL (Standard Tessellation Language files) and the DICOM (Digital Imaging and Communications in Medicine) files were registered on a 3D planning software. A CAD/CAM surgical guide was planned, resin printed and used for installing the 6 implants bilaterally. In group V, the framework was designed based on the virtual scan bodies and virtual multi-unit abutments, while in group A intra-oral scanning of the model after attaching the scan bodies was necessary. Frameworks of both groups were milled and tested for passive fit using 8 tests. Fisher’s Exact test was used to compare between the two groups and the subgroups of the casts. The significance level was set at P ≤ 0.05. Results: No statistical significant difference in the passive fit of group V and group A frameworks was found (p-value=.044, OR=2.667). Regarding ridge form, no statistically significant difference was found between normal and thin ridges, whether in group V or A (P-value =.100).
Conclusion: Within the limitations of this study, the following can be concluded: In free end saddle cases, CAD\CAM 3-unit implant-supported frameworks designed and fabricated based on virtual implant positions have less chances of passive fit than those designed on actual ones. Also, ridge form affects the passive fit of the frameworks designed based on virtual implant positions هذه دراسة تقارن بين التوافق السلبي لالأطر المصممة والمصنعة وفقًا لاماكن الزرع الفعلية, و تلك التي تم صنعها وفقًا لاماكن الزرع الافتراضية.
في هذه الدراسة ، تم تصميم قالب يمثل تصنيف كينيدي من الفئة الأولى مطبوع بتقنية ثلاثي الأبعاد تم مسحه ضوئيًا باستخدام ماسح ضوئي داخل الفم لتلقي 3 غرسات ثنائية في كل جانب باستخدام الدليل الجراحي . سيتم تعويض كل جانب بواسطة 3 وحدات من إطار الكوبالت الكروم. سيتم تصميم أحد هذه الأطر بشكل كامل وبناؤه افتراضيًا ومثبتًا في دعامات متعددة الوحدات. على الجانب الآخر ، سيتم إرفاق أجسام المسح بالزرعات ومسحها ضوئيًا باستخدام ماسح ضوئي داخل الفم. سيتم تنفيذ التصميم وتصنيعه للحصول على 3 إطارات وحدات مثبتة ببراغي في دعامات متعددة الوحدات. يتم قياس التوافق السلبي باستخدام الاختبارات عدة وهي: اختبار برغي واحد و استقرار التركيبة و انزلاق الخيط الطبي واختبار مقاومة المسمار وتقييم شعاعي والوسائل الكاشفى للضغط. اختبار برغي واحد هو شد مسمار واحد ، تستلزم الخطوة الأولى تشديد دعامة واحدة بعيدة إلى الإطار وتقييم أي عدم متطابق مابين التركيبة و الزرعات مع ضغط الإصبع والتكبير يُظهر اختبار مقاومة المسمار أي حالات غير ملائمة تم اكتشافها عند الشد خارج نقطة المعايرة و هذه تشير إلى أن التوافق السلبي لللهيكل غير كافٍ عندما يتم نصف دورة للمسمار الموجود داخل الغرسة. يوفر التقييم الجوهري الراديوي اختبارا أكثر دقة لأي أخطاء في التركيب تقع بين الغرسات وواجهة الأطر حيث يكون وضع الهوامش الفرعية اللثوية أمرًا مضمونًا أظهرت النتائج أن انه لا اختلاف جوهري احصائيا للتوافق السلبي لالأطر التي تم تصميمها وإنشاؤها وفقًا لمواقع الزرع الفعلية تم تركيبها و تلك التي تم إنشاؤها وفقًا لمواقع الزرع الافتراضية او اختلاف علي حسب شكل العظم.
Text in English and abstract in English.
Implant surgery
CAD\CAM virtual actual guided implant surgery frameworks
617.605