Detection and sensing of ozone gas by orange LED /
Maysa Ahmed Mohamed Ibrahim,
Detection and sensing of ozone gas by orange LED / كشف واستشعار غاز الاوزون باستخدام الموحد الباعث للضوء البرتقالى / by Maysa Ahmed Mohamed Ibrahim ; Supervisors Prof. Dr. Gamal Abdel Fattah Ali, Dr. Mahmoud Gomaa Mahmoud Habieb. - 300 pages : illustrations ; 25 cm. + CD.
Thesis (M.Sc)-Cairo University, 2024.
Bibliography: pages 60-68.
Ozone gas detection is the main interest in this work because it is a hazardous material that is frequently present in or produced by human surroundings (aircraft cabins, workplaces with photocopiers, laser printers, and sterilizers). The measurement of ozone concentration based on the visible absorption method is investigated by using an orange LED with an emission peak at 591 nm as a light source and a silicon photo-transistor sensitive in the visible light region as the photo detector for different optical path lengths (50 cm, 30 cm, and 10 cm). The rule of measurement is based on the absorption of visible light in the Chappuis band.
A linear calibration curve of transmitted intensity versus ozone concentration for different optical path lengths was determined. This calibration curve shows the possibility to monitor the existence of ozone and its concentration. The sensitivity (S) is calculated and give the value 0.00256 m3/g for longer path length measurements (50 cm).
The idea of dosimeter is used as an indicator for the ozone existence by studying the emission of a porous silicon cell. The effect of ozone on the porous silicon photoluminescence (PL) for different ozone concentrations is measured and shows the decreasing of porous silicon PL peak intensity with the increasing ozone concentration, but the PL peak intensity shows a permanent decrease even after ozone is removed from the Pyrex glass tube. A one-week room-temperature aging of the porous silicon dosimeter is used to reactivate the dosimeter. Temperature treatment for 30 minutes at (50 ͦ C, 70 ͦ c, and 90 ͦ C) is proceed to reactivate the dosimeter. The best reactivation is obtained for 90 ͦ C treatment, where the PL intensity almost returns to its initial intensity before ozone exposure.
The porous silicon is kept at a temperature 50 ͦ C, and the PL is measured as a function of ozone concentrations, best monitoring is obtained for low concentrations (10-45) g/m3. يعد الكشف عن غاز الأوزون هو الاهتمام الرئيسي في هذا العمل لأنه مادة خطرة تتواجد بشكل متكرر في البيئة البشرية أو تنتجها (كبائن الطائرات وأماكن العمل المزودة بآلات النسخ وطابعات الليزر وأجهزة التعقيم). تم قياس تركيز الأوزون على أساس طريقة الامتصاص المرئي باستخدام مصباح LED برتقالي ذو ذروة انبعاث عند 591 نانومتر كمصدر للضوء وترانزستور ضوئي من السيليكون حساس في منطقة الضوء المرئي ككاشف ضوئي لأطوال المسار البصري المختلفة. (50 سم، 30 سم، 10 سم). تعتمد قاعدة القياس على امتصاص الضوء المرئي في نطاق تشابيوس.
تم تحديد منحنى المعايرة الخطية للكثافة المنقولة مقابل تركيز الأوزون لأطوال المسار البصري المختلفة. يوضح منحنى المعايرة إمكانية مراقبة وجود الأوزون وتركيزه. يتم حساب الحساسية (S) وتعطى القيمة 0.00256 م3/جم لقياسات طول المسار الأطول (50 سم).
تُستخدم فكرة مقياس الجرعات كمؤشر لوجود الأوزون من خلال دراسة انبعاث خلية سيليكون مسامية. يتم قياس تأثير الأوزون على انبعاث السيليكون المسامي الضوئ ( PL) لتركيزات مختلفة للأوزون ويظهر تناقص كثافة ذروة السيليكون المسامي PL مع زيادة تركيز الأوزون، لكن كثافة ذروة PL تظهر انخفاضًا دائمًا حتى بعد إزالة الأوزون من أنبوب زجاجي بيركس. يتم استخدام تقادم درجة حرارة الغرفة لمدة أسبوع لمقياس الجرعات السيليكوني المسامي لإعادة تنشيط مقياس الجرعات. تتم معالجة درجة الحرارة لمدة 30 دقيقة عند (50 درجة مئوية، 70 درجة مئوية، و90 درجة مئوية) لإعادة تنشيط مقياس الجرعات. يتم الحصول على أفضل إعادة تنشيط عند المعالجة بدرجة حرارة 90 درجة مئوية، حيث تعود كثافة PL تقريبًا إلى شدتها الأولية قبل التعرض للأوزون.
يتم الاحتفاظ بالسيليكون المسامي عند درجة حرارة 50 درجة مئوية، ويتم قياس PL كدالة لتركيزات الأوزون، ويتم الحصول على أفضل مراقبة للتركيزات المنخفضة (10-45) جم / م3.
Text in English and abstract in Arabic & English.
Ozone gas
Ozone gas Sensor Porous Silicon cell LED Ozone concentrations. Absorption Coefficient Optical path length Photoluminescence
551.5142
Detection and sensing of ozone gas by orange LED / كشف واستشعار غاز الاوزون باستخدام الموحد الباعث للضوء البرتقالى / by Maysa Ahmed Mohamed Ibrahim ; Supervisors Prof. Dr. Gamal Abdel Fattah Ali, Dr. Mahmoud Gomaa Mahmoud Habieb. - 300 pages : illustrations ; 25 cm. + CD.
Thesis (M.Sc)-Cairo University, 2024.
Bibliography: pages 60-68.
Ozone gas detection is the main interest in this work because it is a hazardous material that is frequently present in or produced by human surroundings (aircraft cabins, workplaces with photocopiers, laser printers, and sterilizers). The measurement of ozone concentration based on the visible absorption method is investigated by using an orange LED with an emission peak at 591 nm as a light source and a silicon photo-transistor sensitive in the visible light region as the photo detector for different optical path lengths (50 cm, 30 cm, and 10 cm). The rule of measurement is based on the absorption of visible light in the Chappuis band.
A linear calibration curve of transmitted intensity versus ozone concentration for different optical path lengths was determined. This calibration curve shows the possibility to monitor the existence of ozone and its concentration. The sensitivity (S) is calculated and give the value 0.00256 m3/g for longer path length measurements (50 cm).
The idea of dosimeter is used as an indicator for the ozone existence by studying the emission of a porous silicon cell. The effect of ozone on the porous silicon photoluminescence (PL) for different ozone concentrations is measured and shows the decreasing of porous silicon PL peak intensity with the increasing ozone concentration, but the PL peak intensity shows a permanent decrease even after ozone is removed from the Pyrex glass tube. A one-week room-temperature aging of the porous silicon dosimeter is used to reactivate the dosimeter. Temperature treatment for 30 minutes at (50 ͦ C, 70 ͦ c, and 90 ͦ C) is proceed to reactivate the dosimeter. The best reactivation is obtained for 90 ͦ C treatment, where the PL intensity almost returns to its initial intensity before ozone exposure.
The porous silicon is kept at a temperature 50 ͦ C, and the PL is measured as a function of ozone concentrations, best monitoring is obtained for low concentrations (10-45) g/m3. يعد الكشف عن غاز الأوزون هو الاهتمام الرئيسي في هذا العمل لأنه مادة خطرة تتواجد بشكل متكرر في البيئة البشرية أو تنتجها (كبائن الطائرات وأماكن العمل المزودة بآلات النسخ وطابعات الليزر وأجهزة التعقيم). تم قياس تركيز الأوزون على أساس طريقة الامتصاص المرئي باستخدام مصباح LED برتقالي ذو ذروة انبعاث عند 591 نانومتر كمصدر للضوء وترانزستور ضوئي من السيليكون حساس في منطقة الضوء المرئي ككاشف ضوئي لأطوال المسار البصري المختلفة. (50 سم، 30 سم، 10 سم). تعتمد قاعدة القياس على امتصاص الضوء المرئي في نطاق تشابيوس.
تم تحديد منحنى المعايرة الخطية للكثافة المنقولة مقابل تركيز الأوزون لأطوال المسار البصري المختلفة. يوضح منحنى المعايرة إمكانية مراقبة وجود الأوزون وتركيزه. يتم حساب الحساسية (S) وتعطى القيمة 0.00256 م3/جم لقياسات طول المسار الأطول (50 سم).
تُستخدم فكرة مقياس الجرعات كمؤشر لوجود الأوزون من خلال دراسة انبعاث خلية سيليكون مسامية. يتم قياس تأثير الأوزون على انبعاث السيليكون المسامي الضوئ ( PL) لتركيزات مختلفة للأوزون ويظهر تناقص كثافة ذروة السيليكون المسامي PL مع زيادة تركيز الأوزون، لكن كثافة ذروة PL تظهر انخفاضًا دائمًا حتى بعد إزالة الأوزون من أنبوب زجاجي بيركس. يتم استخدام تقادم درجة حرارة الغرفة لمدة أسبوع لمقياس الجرعات السيليكوني المسامي لإعادة تنشيط مقياس الجرعات. تتم معالجة درجة الحرارة لمدة 30 دقيقة عند (50 درجة مئوية، 70 درجة مئوية، و90 درجة مئوية) لإعادة تنشيط مقياس الجرعات. يتم الحصول على أفضل إعادة تنشيط عند المعالجة بدرجة حرارة 90 درجة مئوية، حيث تعود كثافة PL تقريبًا إلى شدتها الأولية قبل التعرض للأوزون.
يتم الاحتفاظ بالسيليكون المسامي عند درجة حرارة 50 درجة مئوية، ويتم قياس PL كدالة لتركيزات الأوزون، ويتم الحصول على أفضل مراقبة للتركيزات المنخفضة (10-45) جم / م3.
Text in English and abstract in Arabic & English.
Ozone gas
Ozone gas Sensor Porous Silicon cell LED Ozone concentrations. Absorption Coefficient Optical path length Photoluminescence