Application of nanoparticles modified electrochemical sensor for the detection of serotonin /
Aya Gamal Abd El-Nasser Kamel Abd El-Latif, 
Application of nanoparticles modified electrochemical sensor for the detection of serotonin / تطبيق مجس كهروكيميائي معدل بالجسيمات النانوية للكشف عن السيروتونين by Aya Gamal Abd El-Nasser Kamel Abd El-Latif ; supervisors Prof. Dr. Rasha Mohamed El Nashar, Prof. Dr. Azza Abd Elwahab Shoukry . - 135 pages : illustrations ; 25 cm. + CD.
Thesis (M.Sc)-Cairo University, 2025.
Bibliography: pages 109-135.
A novel modified sensor based on electropolymerization of hippuric acid (HA) using cyclic voltammetry within the potential window -1.0 to 1.5 V for 10 cycles at a scan rate 100 mV s−1 over multiwalled carbon nanotubes (MWCNTs) on battery graphite electrode (BGE) was developed. Poly (HA)/MWCNTs/BGE sensor exhibited two linearity ranges 3.00 x 10-3 to 1.00 μM (5.29 × 10-4 – 0.18 μg/ml) and 5.00 to 1.00 x
103 μM (0.88 –176.22 μg/ml) with limit of detection (LOD) of 0.06 x 10-2 μM (1.06 x 10-4 μg/ml) and limit of quantification (LOQ) of 2.00 x 10-3 μM (3.52×10-4 μg/ml). The poly (HA)/MWCNTs/BGE sensor was successfully applied to the determination of SER in the presence of tryptophan and in human blood serum with recovery ranges 98.31%–105.47% with RSD values 3.02%– 4.77%. Green chemistry metrics: national environmental index (NEMI), analytical greenness metric (AGREE), Raynie and Driver, green analytical procedure index (GAPI), and the analytical eco-scale were employed and indicated that the proposed sensor can be classified as an excellent green method, achieving an analytical eco-scale score of 84. تم تطوير مستشعر مبتكر معدل يعتمد على البلمرة الكهربية لحمض الهيبوريك باستخدام تقنية
الفولتامترية الدورية ضمن نطاق جهد يتراوح بين 1- و 1.5 فولت لمدة 10 دورات وبمعدل مسح 100 مللي فولت/ثانية، وذلك على سطح إلكترود الجرافيت المغطى بأنابيب الكربون النانوية متعددة الجدران
.(MWCNTs) أظهر المستشعر (HA)/MWCNTs/BGE Poly نطاقين خطيين يتراوحان
بين 10-3 x 1.00–3.00 ميكرومولار ) 10-4 × 5.29 – 0.18 ميكروغرام/مل( وبين 5.00 – 1.00
103 x ميكرومولار 0.88) – 176.22 ميكروغرام/مل(، مع حد الكشف (LOD) البالغ 10- x 0.06
2 ميكرومولار ) 10-4 x 1.06 ميكروغرام/مل( وحد القياس الكمي (LOQ) البالغ 10-3 x 2.00 ميكرومولار ) 3.52×10-4 ميكروغرام/مل.( تم تطبيق المستشعر بنجاح في الكشف عن السيروتونين
في وجود التريبتوفان (TRP) في نطاق ديناميكي خطي يتراوح بين 5.00 إلى 103 x 1.00
ميكرومولار 0.88) – 176.22 ميكروغرام/مل(، كما تم استخدامه لتحليل السيروتونين في مصل الدم البشري مع تحقيق نسب استرداد تراوحت بين %98.31 إلى %105.47 مع نسب انحراف معياري نسبي (RSD) تتراوح بين %3.02 – .%4.77
تم تقييم المؤشرات البيئية الخضراء للمستشعر وذلك باستخدام مؤشر البيئة الوطني (NEMI)، مقياس التحليل الأخضر(AGREE)، طريقة رايني ودرايف Driver) and (Raynie، مؤشر الإجراء
يمكن
التحليلي الأخضر (GAPI)، والمقياس البيئي التحليلي. وأظهرت النتائج أن المستشعر المقترح تصنيفه كطريقة خضراء ممتازة، محققًا درجة إيكولوجية تحليلية بلغت .84
Text in English and abstract in Arabic & English.
Electrochemical analysis
التحليل الكهربائي الكيميائي
Serotonin sensors electropolymerization hippuric acid modified electrodes
543.0871
                        Application of nanoparticles modified electrochemical sensor for the detection of serotonin / تطبيق مجس كهروكيميائي معدل بالجسيمات النانوية للكشف عن السيروتونين by Aya Gamal Abd El-Nasser Kamel Abd El-Latif ; supervisors Prof. Dr. Rasha Mohamed El Nashar, Prof. Dr. Azza Abd Elwahab Shoukry . - 135 pages : illustrations ; 25 cm. + CD.
Thesis (M.Sc)-Cairo University, 2025.
Bibliography: pages 109-135.
A novel modified sensor based on electropolymerization of hippuric acid (HA) using cyclic voltammetry within the potential window -1.0 to 1.5 V for 10 cycles at a scan rate 100 mV s−1 over multiwalled carbon nanotubes (MWCNTs) on battery graphite electrode (BGE) was developed. Poly (HA)/MWCNTs/BGE sensor exhibited two linearity ranges 3.00 x 10-3 to 1.00 μM (5.29 × 10-4 – 0.18 μg/ml) and 5.00 to 1.00 x
103 μM (0.88 –176.22 μg/ml) with limit of detection (LOD) of 0.06 x 10-2 μM (1.06 x 10-4 μg/ml) and limit of quantification (LOQ) of 2.00 x 10-3 μM (3.52×10-4 μg/ml). The poly (HA)/MWCNTs/BGE sensor was successfully applied to the determination of SER in the presence of tryptophan and in human blood serum with recovery ranges 98.31%–105.47% with RSD values 3.02%– 4.77%. Green chemistry metrics: national environmental index (NEMI), analytical greenness metric (AGREE), Raynie and Driver, green analytical procedure index (GAPI), and the analytical eco-scale were employed and indicated that the proposed sensor can be classified as an excellent green method, achieving an analytical eco-scale score of 84. تم تطوير مستشعر مبتكر معدل يعتمد على البلمرة الكهربية لحمض الهيبوريك باستخدام تقنية
الفولتامترية الدورية ضمن نطاق جهد يتراوح بين 1- و 1.5 فولت لمدة 10 دورات وبمعدل مسح 100 مللي فولت/ثانية، وذلك على سطح إلكترود الجرافيت المغطى بأنابيب الكربون النانوية متعددة الجدران
.(MWCNTs) أظهر المستشعر (HA)/MWCNTs/BGE Poly نطاقين خطيين يتراوحان
بين 10-3 x 1.00–3.00 ميكرومولار ) 10-4 × 5.29 – 0.18 ميكروغرام/مل( وبين 5.00 – 1.00
103 x ميكرومولار 0.88) – 176.22 ميكروغرام/مل(، مع حد الكشف (LOD) البالغ 10- x 0.06
2 ميكرومولار ) 10-4 x 1.06 ميكروغرام/مل( وحد القياس الكمي (LOQ) البالغ 10-3 x 2.00 ميكرومولار ) 3.52×10-4 ميكروغرام/مل.( تم تطبيق المستشعر بنجاح في الكشف عن السيروتونين
في وجود التريبتوفان (TRP) في نطاق ديناميكي خطي يتراوح بين 5.00 إلى 103 x 1.00
ميكرومولار 0.88) – 176.22 ميكروغرام/مل(، كما تم استخدامه لتحليل السيروتونين في مصل الدم البشري مع تحقيق نسب استرداد تراوحت بين %98.31 إلى %105.47 مع نسب انحراف معياري نسبي (RSD) تتراوح بين %3.02 – .%4.77
تم تقييم المؤشرات البيئية الخضراء للمستشعر وذلك باستخدام مؤشر البيئة الوطني (NEMI)، مقياس التحليل الأخضر(AGREE)، طريقة رايني ودرايف Driver) and (Raynie، مؤشر الإجراء
يمكن
التحليلي الأخضر (GAPI)، والمقياس البيئي التحليلي. وأظهرت النتائج أن المستشعر المقترح تصنيفه كطريقة خضراء ممتازة، محققًا درجة إيكولوجية تحليلية بلغت .84
Text in English and abstract in Arabic & English.
Electrochemical analysis
التحليل الكهربائي الكيميائي
Serotonin sensors electropolymerization hippuric acid modified electrodes
543.0871