Behavior of strengthened reinforced concrete columns after exposure to elevated temperature /
Marina Alkess Kerllos Ibrahim,
Behavior of strengthened reinforced concrete columns after exposure to elevated temperature / دراسة سلوك الأعمدة الخرسانية المسلحة المدعمة بعد تعرضها لدرجات الحرارة العالية by Marina Alkess Kerllos Ibrahim ; Supervisors Prof. Dr. Mohamed El-said said Issa, Prof. Dr. Khaled Farouk Omar El-Kashif. - 209 pages : illustrations ; 30 cm. + CD.
Thesis (Ph.D)-Cairo University, 2025.
Bibliography: pages 206-209.
In this research, different techniques of repair of fired R.C. columns are compared. These
include Carbon Fiber Reinforced Polymers (CFRP) sheets, steel jackets, and R.C. jackets.
The main variables were considered, the strengthening technique, fire duration, degree of
temperature, concrete cover, concrete compressive strength and the column cross section.
The experimental investigation includes testing of twelve columns. The experimental
results showed that the three strengthening techniques used in this study significantly
improved the ultimate load-carrying capacity. Increasing the elevated temperature
duration, decreased the ultimate carrying capacity of the RC column when subjected to
elevated temperatures. The concrete compressive strength of the columns decreased by
approximately 20 % and 50 % at elevated temperatures of 400 °C and 600 °C,
respectively. In addition, an increase in the temperature resulted in a reduction in the load
capacity with` an increase in the axial displacement of the tested columns. The
experimental results and the theoretical results showed a conservative difference of 5%. عند تعرض الأعمدة الخرسانية لدرجات حرارة مرتفعة أو النار، تبدأ قوتها في التدهور. لذلك، يجب تقوية أو إصلاح العمود التالف. في هذا البحث، يتم مقارنة ثلاث تقنيات مختلفة لتدعيم الأعمدة الخرسانية المسلحة التي تتعرض للحريق. عند زيادة زمن الحريق، تنخفض القدرة على تحمل الأعمدة المسلحة عند تعرضها لدرجات حرارة مرتفعة. وهكذا تنخفض قدرة الأعمدة على تحمل الحمل النهائي بنسبة تقدر بحوالي 20 %، و 50 % عند درجات حرارة مرتفعة قدرها 400و 600درجة مئوية على التوالي. أيضًا، أدى زيادة درجة الحرارة إلى انخفاض في قدرة التحمل مع زيادة الازاحة للأعمدة المختبرة. أظهرت النتائج المعملية والنتائج النظرية فرقًا طفيفا بنسبة 5٪.
Text in English and abstract in Arabic & English.
Columns Concrete
أعمدة خرسانية
RC column Column strengthening Reinforced Concrete jacket Steel jacket Carbon- Fiber-Reinforced polymer wrapping elevated temperature duration Degree of temperature
624.183
Behavior of strengthened reinforced concrete columns after exposure to elevated temperature / دراسة سلوك الأعمدة الخرسانية المسلحة المدعمة بعد تعرضها لدرجات الحرارة العالية by Marina Alkess Kerllos Ibrahim ; Supervisors Prof. Dr. Mohamed El-said said Issa, Prof. Dr. Khaled Farouk Omar El-Kashif. - 209 pages : illustrations ; 30 cm. + CD.
Thesis (Ph.D)-Cairo University, 2025.
Bibliography: pages 206-209.
In this research, different techniques of repair of fired R.C. columns are compared. These
include Carbon Fiber Reinforced Polymers (CFRP) sheets, steel jackets, and R.C. jackets.
The main variables were considered, the strengthening technique, fire duration, degree of
temperature, concrete cover, concrete compressive strength and the column cross section.
The experimental investigation includes testing of twelve columns. The experimental
results showed that the three strengthening techniques used in this study significantly
improved the ultimate load-carrying capacity. Increasing the elevated temperature
duration, decreased the ultimate carrying capacity of the RC column when subjected to
elevated temperatures. The concrete compressive strength of the columns decreased by
approximately 20 % and 50 % at elevated temperatures of 400 °C and 600 °C,
respectively. In addition, an increase in the temperature resulted in a reduction in the load
capacity with` an increase in the axial displacement of the tested columns. The
experimental results and the theoretical results showed a conservative difference of 5%. عند تعرض الأعمدة الخرسانية لدرجات حرارة مرتفعة أو النار، تبدأ قوتها في التدهور. لذلك، يجب تقوية أو إصلاح العمود التالف. في هذا البحث، يتم مقارنة ثلاث تقنيات مختلفة لتدعيم الأعمدة الخرسانية المسلحة التي تتعرض للحريق. عند زيادة زمن الحريق، تنخفض القدرة على تحمل الأعمدة المسلحة عند تعرضها لدرجات حرارة مرتفعة. وهكذا تنخفض قدرة الأعمدة على تحمل الحمل النهائي بنسبة تقدر بحوالي 20 %، و 50 % عند درجات حرارة مرتفعة قدرها 400و 600درجة مئوية على التوالي. أيضًا، أدى زيادة درجة الحرارة إلى انخفاض في قدرة التحمل مع زيادة الازاحة للأعمدة المختبرة. أظهرت النتائج المعملية والنتائج النظرية فرقًا طفيفا بنسبة 5٪.
Text in English and abstract in Arabic & English.
Columns Concrete
أعمدة خرسانية
RC column Column strengthening Reinforced Concrete jacket Steel jacket Carbon- Fiber-Reinforced polymer wrapping elevated temperature duration Degree of temperature
624.183