Validity and reliability of autocad software assessement of knee joint position sense in patellofemoral pain syndrome /
Nada Magdy Saad Eldeen Abdelaziz
Validity and reliability of autocad software assessement of knee joint position sense in patellofemoral pain syndrome / مدي صلاحية و مصداقية استخدام برنامج الاوتوكاد في قياس الاحساس المفصلى العميق في مرضى متلازمة الم الرضفة Nada Magdy Saad Eldeen Abdelaziz ; Supervised Salwa Fadl Abdelmageed , Karima Abdelaty Hassan , Ahmad Hamdi Azzam - Cairo : Nada Magdy Saad Eldeen Abdelaziz , 2019 - 80 P. : charts , facsimiles ; 25cm
Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Musculoskeletal Disorders
Background: Patellofemoral pain syndrome is a common, painful musculoskeletal condition that affects physically active young adults and adolescents. Proprioception is an important mechanism in knee stability and function. In PFPS changes appear in knee proprioception which play a major role in rehabilitation. There are several methods to measure proprioception; therapists require portable, valid, and cost-effective methods to monitor knee joint-position-sense (JPS) ability. Purpose: to investigate the validity and reliability of Autocad software in measuring joint position sense in patients with patellofemoral pain syndrome. Methods: thirty-nine patients (11 males and 28 females), with age ranged from 18 to35 years with mean age (24.25±3.40) years, mean weight (68.71±16.01) Kg, and mean height (164.07±10.14) cm. All subjects were assessed by the same examiner on two occasions two days apart.Validity was assessed for image capture and AutoCAD software analysis against isokinetic dynamometer device (IKD) also intra-tester reliability for image capture and AutoCAD software was obtained by the same examiner on two days apart
Isokinetic dynamometer Joint position sense Patellofemoral pain syndrome
Validity and reliability of autocad software assessement of knee joint position sense in patellofemoral pain syndrome / مدي صلاحية و مصداقية استخدام برنامج الاوتوكاد في قياس الاحساس المفصلى العميق في مرضى متلازمة الم الرضفة Nada Magdy Saad Eldeen Abdelaziz ; Supervised Salwa Fadl Abdelmageed , Karima Abdelaty Hassan , Ahmad Hamdi Azzam - Cairo : Nada Magdy Saad Eldeen Abdelaziz , 2019 - 80 P. : charts , facsimiles ; 25cm
Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Musculoskeletal Disorders
Background: Patellofemoral pain syndrome is a common, painful musculoskeletal condition that affects physically active young adults and adolescents. Proprioception is an important mechanism in knee stability and function. In PFPS changes appear in knee proprioception which play a major role in rehabilitation. There are several methods to measure proprioception; therapists require portable, valid, and cost-effective methods to monitor knee joint-position-sense (JPS) ability. Purpose: to investigate the validity and reliability of Autocad software in measuring joint position sense in patients with patellofemoral pain syndrome. Methods: thirty-nine patients (11 males and 28 females), with age ranged from 18 to35 years with mean age (24.25±3.40) years, mean weight (68.71±16.01) Kg, and mean height (164.07±10.14) cm. All subjects were assessed by the same examiner on two occasions two days apart.Validity was assessed for image capture and AutoCAD software analysis against isokinetic dynamometer device (IKD) also intra-tester reliability for image capture and AutoCAD software was obtained by the same examiner on two days apart