Cranioplasty Using Patient Specific Implants Polyether Ether Ketone Versus Ultra-High Molecular Weight Polyethylene : (Record no. 171795)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 05832namaa22004331i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | OSt |
| 005 - أخر تعامل مع التسجيلة | |
| control field | 20250505115255.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250429s2023 ua a|||fr|||m 000 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Original cataloguing agency | EG-GICUC |
| Language of cataloging | eng |
| Transcribing agency | EG-GICUC |
| Modifying agency | EG-GICUC |
| Description conventions | rda |
| 041 0# - LANGUAGE CODE | |
| Language code of text/sound track or separate title | eng |
| Language code of summary or abstract | eng |
| -- | ara |
| 049 ## - Acquisition Source | |
| Acquisition Source | Deposit |
| 082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER | |
| Classification number | 617 |
| 092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC) | |
| Classification number | 617 |
| Edition number | 21 |
| 097 ## - Degree | |
| Degree | Ph.D |
| 099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
| Local Call Number | Cai01.09.13.Ph.D.2023.Ma.C. |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Authority record control number or standard number | Mariam Salah Kamel Abdelwahed , |
| Preparation | preparation. |
| 245 10 - TITLE STATEMENT | |
| Title | Cranioplasty Using Patient Specific Implants Polyether Ether Ketone Versus Ultra-High Molecular Weight Polyethylene : |
| Remainder of title | A Randomized Controlled Trial / |
| Statement of responsibility, etc. | By Mariam Salah Kamel Abdelwahed; Supervisors Prof. Dr. Mamdouh Sayed Sayed Ahmed, Prof. Dr. Mohamed Bassiouny, Assistant Prof. Dr. Sherif Ali. |
| 246 15 - VARYING FORM OF TITLE | |
| Title proper/short title | إعادة بناء عظم الجمجمة بواسطة رقعات محاكية خاصة للمريض الپولي إيثر إيثر كيتون مقابل الپولي إيثيلين ذو الجزيئات فائقة الوزن : |
| Remainder of title | دراسة مُعَشَّاة مُضَبَّطَة / |
| 264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
| Date of production, publication, distribution, manufacture, or copyright notice | 2023. |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 96 pages : |
| Other physical details | illustrations ; |
| Dimensions | 25 cm. + |
| Accompanying material | CD. |
| 336 ## - CONTENT TYPE | |
| Content type term | text |
| Source | rda content |
| 337 ## - MEDIA TYPE | |
| Media type term | Unmediated |
| Source | rdamedia |
| 338 ## - CARRIER TYPE | |
| Carrier type term | volume |
| Source | rdacarrier |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Thesis (Ph.D)-Cairo University, 2023. |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE | |
| Bibliography, etc. note | Bibliography: pages 89-96. |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | Aim: To report our experience with synthetic reconstruction of cranial defects using milled patient specific Ultra-high molecular weight polyethylene cranial plates, in terms of benefits and limitations in comparison to Polyether ether ketone cranial plates. <br/>Methods: In this study, we included 22 patients with cranial defects from a previous craniectomy, or patients eligible for simultaneous craniectomy and cranioplasty via computer designed patient specific implants and excluded cases with active infection or hydrocephalus. Patients were divided into two equal groups, group I study and group II control. We evaluated cosmetic patient satisfaction and overall complications and failure rates of both materials over six months.<br/>Results: The Average satisfaction score was 4.8 in group I and 4.5 in group II with no statistically significant difference. Seventeen (77.3%) patients were without any complications. None of the cases in both groups developed any clinical or radiographic signs of infection, nor suffered implant failure. Overall complication rates for Ultra-high molecular weight polyethylene and Poly ether ketone cranioplasty were 27.3% and 18.2%, respectively. The difference in complication rate between the two groups was of no statistical significance.<br/>Conclusion: Our study highlights that Ultra-high molecular weight polyethylene is a promising synthetic solution for complex calvarial defects. There were no differences in the complication rates comparing it to PEEK cranioplasty at half its price. It is hoped that this information will provide better understanding of the risks associated with cranioplasty and will be useful in clinician decision making and patient choice of a cranioplasty implant.<br/> |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | تضمنت الدراسة ۲۲ مريضاً باستئصال جزئى للجمجمة، تم تقسيمهم بالتساوي إلى مجموعتين لإعادة بناء عظام الجمجمة بواسطة رقعات محاكية خاصة للمريض، المجموعة الدراسية الأولى-الپولي إيثيلين ذو الجزيئات فائقة الوزن والمجموعة المقارنة الثانية-الپولي إيثر إيثر كيتون. تسعة مرضى كانت لديهم محاولات لإعادة بناء سابقة، وأربعة خضعوا لاستئصال أولي فوري وإعادة بناء بمساعدة أدلة القطع، وتسعة منهم خضعوا لإعادة بناء متأخرة للفجوة العظمية. تم إجراء المتابعة السريرية والشعاعية لمدة ستة أشهر بعد الجراحة. كانت النتيجة الأولية هي قياس مدى رضاء المريض عن المظهر الجمالى، بينما كانت النتائج الثانوية قياس المضاعفات عامة وفشل الرقعة. كان متوسط درجة الرضا ٤.٨ للمجموعة الأولى و ٤.٥ لمرضى المجموعة الثانية مع عدم وجود فرق معتد به إحصائيًا بين المجموعتين. لم تظهر أي من الحالات في كلا المجموعتين أي علامات سريرية أو إشعاعية للإلتهاب، ولم تعاني من فشل الرقعة. كانت معدلات المضاعفات الإجمالية للپولي إيثيلين وللپولي إيثر ۲۷.۳ ٪ و ۱٨.۲٪ على التوالي، مع معدل مضاعفات مشترك بنسبة ۲۲.۷ ٪. لم يكن للاختلاف في معدل المضاعفات بين المجموعتين دلالة إحصائية. تسلط دراستنا الضوء على أن مادة الپولي إيثيلين ذو الجزيئات فائقة الوزن هى حل اصطناعي واعد لنواقص الجمجمة المعقدة. |
| 530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
| Issues CD | Issued also as CD |
| 546 ## - LANGUAGE NOTE | |
| Text Language | Text in English and abstract in Arabic & English. |
| 650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Dentistry |
| Source of heading or term | qrmak |
| 653 #0 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Cranioplasty |
| -- | Cranial reconstruction |
| -- | UHMWP |
| -- | PEEK |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Mamdouh Sayed Sayed Ahmed |
| Relator term | thesis advisor. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Mohamed Bassiouny |
| Relator term | thesis advisor. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Sherif Ali |
| Relator term | thesis advisor. |
| 900 ## - Thesis Information | |
| Grant date | 01-01-2023 |
| Supervisory body | Mamdouh Sayed Sayed Ahmed |
| -- | Mohamed Bassiouny |
| -- | Mohamed Bassiouny |
| Universities | Cairo University |
| Faculties | Faculty of Dentistry |
| Department | Department of Oral and Maxillofacial Surgery |
| 905 ## - Cataloger and Reviser Names | |
| Cataloger Name | Eman El gebaly |
| Reviser Names | Eman Ghareb |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Thesis |
| Edition | 21 |
| Suppress in OPAC | No |
| Source of classification or shelving scheme | Home library | Current library | Date acquired | Inventory number | Full call number | Barcode | Date last seen | Effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 29.04.2025 | 91076 | Cai01.09.13.Ph.D.2023.Ma.C. | 01010110091076000 | 29.04.2025 | 29.04.2025 | Thesis |