Assessment of antibacterial effect, solubility, fluoride ion release and compressive strength of glass ionomer containing chlorhexidine versus conventional glass ionomer restorative material : (Record no. 173098)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 08347namaa22004331i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | OSt |
| 005 - أخر تعامل مع التسجيلة | |
| control field | 20250819121038.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250719s2024 ua a|||frm||| 000 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Original cataloguing agency | EG-GICUC |
| Language of cataloging | eng |
| Transcribing agency | EG-GICUC |
| Modifying agency | EG-GICUC |
| Description conventions | rda |
| 041 0# - LANGUAGE CODE | |
| Language code of text/sound track or separate title | eng |
| Language code of summary or abstract | eng |
| -- | ara |
| 049 ## - Acquisition Source | |
| Acquisition Source | Deposit |
| 082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER | |
| Classification number | 617.695 |
| 092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC) | |
| Classification number | 617.695 |
| Edition number | 21 |
| 097 ## - Degree | |
| Degree | M.Sc |
| 099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
| Local Call Number | Cai01.09.10.M.Sc.2023.Wa.A |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Authority record control number or standard number | Waleed Shoaeb Hussein, |
| Preparation | preparation. |
| 245 10 - TITLE STATEMENT | |
| Title | Assessment of antibacterial effect, solubility, fluoride ion release and compressive strength of glass ionomer containing chlorhexidine versus conventional glass ionomer restorative material : |
| Remainder of title | in-vitro study / |
| Statement of responsibility, etc. | by Waleed Shoaeb Hussein ; Supervisors Prof. Dr. Taheya Moussa ,Prof. Dr. Nehal Abou Raya, Prof. Dr. Tamer Mohamed Hamdy. |
| 246 15 - VARYING FORM OF TITLE | |
| Title proper/short title | تقييم التأثير المضاد للبكتيريا ، قابلية الذوبان , أطلاق أيونات الفلورايد والقوة الضاغطة للأيونومر الزجاجي المحتوي على الكلورهيكسيدين مقابل مادة الحشو للأينوميرات التقليدية : |
| Remainder of title | دراسة معملية / |
| 264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
| Date of production, publication, distribution, manufacture, or copyright notice | 2023. |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 89 pages : |
| Other physical details | illustrations ; |
| Dimensions | 25 cm. + |
| Accompanying material | CD. |
| 336 ## - CONTENT TYPE | |
| Content type term | text |
| Source | rda content |
| 337 ## - MEDIA TYPE | |
| Media type term | Unmediated |
| Source | rdamedia |
| 338 ## - CARRIER TYPE | |
| Carrier type term | volume |
| Source | rdacarrier |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Thesis (M.Sc)-Cairo University, 2023. |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE | |
| Bibliography, etc. note | Bibliography: pages 79-83. |
| 520 #3 - SUMMARY, ETC. | |
| Summary, etc. | Aim: The aim of the present study was to evaluate and compare the antibacterial effect against Streptococcus mutans and Lactobacillus acidophilus of chlorhexidine (CHX) modified glass ionomer cement (intervention) versus conventional GIC (control), in addition to its effect on solubility, fluoride ion release and compressive strength.<br/>Methodology: Antibacterial efficiency was evaluated using agar diffusion test (mm). Both CHX modified GIC and conventional GIC prepared samples were added to fresh Streptococcus mutans suspension, incubated for 24 hrs and brain heart infusion media and Lactobacillus acidophilus suspension and Lactobacillus MRS media then incubated for 48 hrs. After incubation period, the inhibition zones were measured using a digital caliper. For the evaluation of solubility, a total of 10-disc shaped samples were used. The samples were weighed using the precision weighing scale to determine their weights before and after immersion in 10 ml distilled water in tightly sealed plastic tubes at 37±2°C for 28 days. The solubility values (μg/mm3) were calculated and recorded for each group. For the evaluation of fluoride ion release (mg F/L), a total of 10-disc shaped samples were used. The fluoride ions released from the prepared samples in distilled water were measured using a fluoride-specific ion electrode, connected to digital ion analyzer. The electrode was calibrated before to each test using standard solutions of 10 ppm and 100 ppm fluoride. For compressive strength, a total of 10-cylinder shaped samples were prepared. Compressive strength was measured using a universal testing machine, with each specimen put with its flat ends between the machine's plates. The compressive force was applied to the samples along their long axis at a crosshead speed of 1mm/minute. The compressive strength in (MPa) was calculated and recorded for both groups.<br/> <br/>Results: Results of antibacterial test in (mm) showed a statistically significant increase in inhibition zones of the intervention group compared to the control group against Streptococcus mutans and Lactobacillus acidophilus in the all the tested time intervals: days 1-2, 7, 14, 21 and 28 (p-value ≤ 0.05). Results of solubility (μg/mm3), fluoride ion release (mg F/L) and compressive strength (MPa) revealed that both groups showed no significant difference between the control group and the intervention group (p-value >0.05). <br/>Conclusion: The addition of Consepsis (2% chlorhexidine gluconate solution) to the conventional Fuji IX glass-ionomer cement promoted the antibacterial effect against Streptococcus mutans and Lactobacillus acidophilus with no deteriorating effect on, solubility, fluoride ion release and compressive strength. |
| 520 #3 - SUMMARY, ETC. | |
| Summary, etc. | الهدف من الدراسة:<br/>كان الهدف من هذه الدراسة هو تقييم النشاط المضاد للبكتيريا وقابلية الذوبان وإطلاق أيون الفلوريد وقوة الانضغاط للأيونومر الزجاجي المحتوي على 2٪ كلورهيكسيدين جلوكونات مقابل مادة الأيونومر الزجاجي التقليدية الترميمية.<br/>ألاساليب المستخدمة:<br/>تمت إضافة محلول الكلورهيكسيدين المضاد للبكتيريا Consepsis® ، Ultradent ، الولايات المتحدة الأمريكية) إلى سائل الأسمنت الأيونومر الزجاجي التقليدي على لوح زجاجي بارد وجاف ، ثم تم دمجه وخلطه جيدًا مع المسحوق باستخدام ملعقة صلبة.<br/>تم تحضير إجمالي عدد 130 عينة GICs في هذه الدراسة. تم تقسيم العينات إلى مجموعتين رئيسيتين حسب نوع المواد. تم تقسيم كل مجموعة إلى أربع مجموعات فرعية وفقًا لنوع الاختبار وتم اختبار اختبار انتشار الأجار على فترات زمنية مختلفة (1 ، 7 ، 14 ، 21 ، 28 يومًا.<br/>تم تحضير خمسة وثلاثين طبق أجار (7 أطباق / مجموعة) باستخدام أجار Brain Heart Infusion (BHI) واستخدم أجار Streptococcus mutans واستخدمت Lactobacillus MRS Agar في Lactobacillus acidophilus. تم سكب أول 20 مل من أجار وتركها لتصلب. بعد ذلك ، تم قياس 0.1 مل من المعلق الميكروبي باستخدام الماصة الدقيقة التلقائية ووضعها على كل طبق أجار. تم نشر المعلق البكتيري في اتجاهين لإعطاء نمو متجانس باستخدام قطعة قطن معقمة.<br/>بعد 24 ساعة لمجموعة Streptococcus mutans و 48 ساعة لمجموعة acidophilus Lactobacillus من الحضانة تم تسجيل النتائج. ومع ذلك ، من أجل تقييم النشاط المضاد للبكتيريا لفترة أطول ، تم إجراء الاختبار أيضًا بعد 14 ، 21 ، 28 يومًا من الحضانة كما ذكرنا سابقًا وتم تسجيل النتائج.<br/>فيما يتعلق بتحديد قابلية الذوبان تم استخدام 10 عينات على شكل قرص. تم وزن العينات باستخدام مقياس الوزن الدقيق (Adam Equipment ، المملكة المتحدة) لتحديد الكتلة الأولية (M1). يتم غمر عينات كل مجموعة في 10 مل من الماء المقطر في أنابيب بلاستيكية محكمة الإغلاق. تم تخزين الأنابيب البلاستيكية في حاضنة (Helena- labs ، الولايات المتحدة الأمريكية) عند 37 ± 2 درجة مئوية لمدة 28 يومًا. بعد ذلك ، تمت إزالة العينات من الماء المقطر ، ومسحها بورق ترشيح لإزالة الماء الزائد وتجفيفها عند 37 درجة مئوية لمدة 24 ساعة أخرى في مجفف يحتوي على هلام السيليكا. ثم يتم وزن العينات لتحديد الكتلة الجافة النهائية (M2). |
| 530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
| Issues CD | Issues also as CD. |
| 546 ## - LANGUAGE NOTE | |
| Text Language | Text in English and abstract in Arabic & English. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Dental Materials |
| 653 #1 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Solubility |
| -- | Fluoride Ion |
| -- | Compressive Strength |
| -- | Glass Ionomer |
| -- | Chlorhexidine |
| -- | Restorative Material |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Taheya A. Moussa |
| Relator term | thesis advisor. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Tamer M. Hamdy |
| Relator term | thesis advisor. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Nehal Abou Raya |
| Relator term | thesis advisor. |
| 900 ## - Thesis Information | |
| Grant date | 01-01-2023 |
| Supervisory body | Taheya A. Moussa |
| -- | Tamer M. Hamdy |
| -- | Nehal Abou Raya |
| Discussion body | Sayed Senior |
| -- | Mohamed Hussein Abdel-Fattah Zaazou |
| Universities | Cairo University |
| Faculties | Faculty of Dentistry |
| Department | Department of Dental Materials Science |
| 905 ## - Cataloger and Reviser Names | |
| Cataloger Name | Shimaa |
| Reviser Names | Eman Ghareb |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Thesis |
| Edition | 21 |
| Suppress in OPAC | No |
| Source of classification or shelving scheme | Home library | Current library | Date acquired | Inventory number | Full call number | Barcode | Date last seen | Effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 19.07.2025 | 91795 | Cai01.09.10.M.Sc.2023.Wa.A | 01010110091795000 | 19.07.2025 | 19.07.2025 | Thesis |