Accuracy of digital impressions obtained by different intraoral scanners compared with the laboratory scanner for implants placed in partially edentulous mandible : (Record no. 173271)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 06568namaa22004331i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | OSt |
| 005 - أخر تعامل مع التسجيلة | |
| control field | 20250827132332.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250802s2024 ua a|||frm||| 000 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Original cataloguing agency | EG-GICUC |
| Language of cataloging | eng |
| Transcribing agency | EG-GICUC |
| Modifying agency | EG-GICUC |
| Description conventions | rda |
| 041 0# - LANGUAGE CODE | |
| Language code of text/sound track or separate title | eng |
| Language code of summary or abstract | eng |
| -- | ara |
| 049 ## - Acquisition Source | |
| Acquisition Source | Deposit |
| 082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER | |
| Classification number | 617.69 |
| 092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC) | |
| Classification number | 617.69 |
| Edition number | 21 |
| 097 ## - Degree | |
| Degree | M.Sc |
| 099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
| Local Call Number | Cai01.09.13.M.Sc.2024.Om.A |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Authority record control number or standard number | Omar Sherif Abdelrahman, |
| Preparation | preparation. |
| 245 10 - TITLE STATEMENT | |
| Title | Accuracy of digital impressions obtained by different intraoral scanners compared with the laboratory scanner for implants placed in partially edentulous mandible : |
| Remainder of title | an in vitro study / |
| Statement of responsibility, etc. | by Omar Sherif Abdelrahman ; Supervision Prof. Dr. Mohamed Farouk, Prof Dr. Amal Kaddah, Dr. Nermeen Ahmed Hassan. |
| 246 15 - VARYING FORM OF TITLE | |
| Title proper/short title | دقة الانطباعات الرقمية التي تم الحصول عليها بواسطة الماسحات الضوئية المختلفة داخل الفم مقارنة بالماسح المختبري للزرع الموضوعة في الفك السفلى عديم الأسنان جزئياَ : |
| Remainder of title | دراسه فى المختبر / |
| 264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
| Date of production, publication, distribution, manufacture, or copyright notice | 2024. |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 80 pages : |
| Other physical details | illustrations ; |
| Dimensions | 25 cm. + |
| Accompanying material | CD. |
| 336 ## - CONTENT TYPE | |
| Content type term | text |
| Source | rda content |
| 337 ## - MEDIA TYPE | |
| Media type term | Unmediated |
| Source | rdamedia |
| 338 ## - CARRIER TYPE | |
| Carrier type term | volume |
| Source | rdacarrier |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Thesis (M.Sc)-Cairo University, 2024. |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE | |
| Bibliography, etc. note | Bibliography: pages 75-78. |
| 520 #3 - SUMMARY, ETC. | |
| Summary, etc. | Aim: The aim of this in vitro study was to evaluate the accuracy of three different intraoral scanners (Medit: i700, 3Shape; Trios 4 and Carestream CS36000) versus the desktop lab scanner for implants placed in Kennedy class II partially edentulous mandible.<br/>Methodology: A 3D printed resin cast simulating Kennedy class II was designed and utilized. Two implants were placed: one in the 1st premolar area and the other one in the 1st molar region. Scan bodies were attached to both implants. Each scan body and the gingival part of the edentulous area were scanned one time by a laboratory scanner to act as the reference scan. Then, they were scanned 5 times with each intraoral scanner. T he scans were compared using Geomagic Control X software to measure the root mean square (RMS) deviation. Statistical tests were conducted to assess and compare trueness and precision between and within groups (scanners and scanned areas).<br/>Results: For trueness, the One-Way ANOVA test showed no statistically significant differences among the three groups for anterior scan body, posterior scan body, and gingival part (P- values: 0.14, 0.45, and 0.40 respectively). For precision, significant differences were found in the posterior scan body (P=0.03) and gingival part (P=0.004), with the 3Shape trios 4 scanner demonstrating the highest precision. No significant differences between the three intraoral scanners were observed for the anterior scan body part (P=0.09).<br/>Conclusions: The study demonstrates that while there are no significant differences in trueness among the three intraoral scanners, significant differences in precision exist for certain scanned parts. These findings highlight the importance of selecting an appropriate scanner based on specific clinical needs and anatomical regions to ensure accurate digital impressions and effective treatment planning. |
| 520 #3 - SUMMARY, ETC. | |
| Summary, etc. | الهدف من إجراء البحث :<br/>لقياس الجذر التربيعي للانحراف (RMS) من أجل حساب كمية الانحراف بين المسحات الرقمية المختلفة. قامت الدراسة بتقييم جانبين رئيسيين من الدقة: الحقيقة والدقة .<br/>الإجراءات المعلمية :<br/>أجريت هذه الدراسة في دقة لثلاثة ماسحات ضوئية داخل الفم (3Shape, Medit, Carestream) و التقاط الانطباعات الرقمية<br/>للقوالب الفكية السفلية الجزئية الخالية من الأسنان من النوع الثاني لكينيدي مع وجود غرستين للاسنان في مناطق الضاحك الأول<br/>والطاحن الأول، تم عمل مسح الضوئي لكل جسم مسحي ولجزء الطبقة اللثوية الموجودة في المنطقة الخالية من الأسنان مرة<br/>واحدة بواسطة ماسح ضوئي مختبري ليكون بمثابة المسح المرجعي، ثم تم مسحهم خمس مرات اخرى بكل ماسح ضوئي على<br/>حدة داخل الفم ، ومن ثم تمت مقارنة المسحات الرقمية مع بعضها البعض وأيضا مقارنة كل منهم مع المسحة المرجعية باستخدام برنامج "Geomagic Control X" لقياس الجذر التربيعي للانحراف (RMS)<br/>أظهرت الدراسة النتائج الاتية :<br/>أن جميع الماسحات الضوئية الثلاثة حققت حقيقة متقاربة في مختلف مناطق القالب، مما يشير إل مستوى عالٍ من الدقة في تكرار الأبعاد الفعلية. ومع ذلك، لوحظت فروق كبيرة في الدقة. أظهر ماسح 3Shape دقة فائقة، لا سيما في التقاط التفاصيل في منطقة الجسم المسحي الخلفي والمنطقة اللثوية .<br/>من خلال نتائج الدراسة يمكن استنتاج الاتى:<br/>أنه في حين أن جميع الماسحات حققت حقيقة متقاربة في جميع المناطق الممسوحة، إلا أن ماسح 3Shape قد مزايا في توفير دقة أكبرفي المناطق الخالية من الأسنان المعقدة. هذه المعلومات ذات قيمة للأطباء عند اختيار ماسح ضوئي داخل الفم، حيث أن الحقيقة والدقة كلاهما مهمان لنجاح التركيبات الصناعية السنية. |
| 530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
| Issues CD | Issues also as CD. |
| 546 ## - LANGUAGE NOTE | |
| Text Language | Text in English and abstract in Arabic & English. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Oral Implant |
| 653 #1 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Trueness |
| -- | Precision |
| -- | scan bodies |
| -- | intraoral scanners |
| -- | precision |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Mohamed Farouk |
| Relator term | thesis advisor. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Amal Kaddah |
| Relator term | thesis advisor. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Nermeen Ahmed Hassan |
| Relator term | thesis advisor. |
| 900 ## - Thesis Information | |
| Grant date | 01-01-2024 |
| Supervisory body | Mohamed Farouk |
| -- | Amal Kaddah |
| -- | Nermeen Ahmed Hassan. |
| Discussion body | Nouran Mahmoud Abdelnabi |
| -- | Bassem Mohsen Abdelhameed |
| Universities | Cairo University |
| Faculties | Faculty of Dentistry |
| Department | Department of Oral Implantology |
| 905 ## - Cataloger and Reviser Names | |
| Cataloger Name | Shimaa |
| Reviser Names | Eman Ghareb |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Thesis |
| Edition | 21 |
| Suppress in OPAC | No |
| Source of classification or shelving scheme | Home library | Current library | Date acquired | Inventory number | Full call number | Barcode | Date last seen | Effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 02.08.2025 | 91839 | Cai01.09.13.M.Sc.2024.Om.A | 01010110091839000 | 02.08.2025 | 02.08.2025 | Thesis |