Marginal fit of selective laser melting co- cr bar versus cast bar on mandibular edentulous casts with two implants supported over denture : (Record no. 176660)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 08818namaa22004331i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | EG-GICUC |
| 005 - أخر تعامل مع التسجيلة | |
| control field | 20251213123457.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 251213s2025 uaa|||frm||| 000 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Original cataloguing agency | EG-GICUC |
| Language of cataloging | eng |
| Transcribing agency | EG-GICUC |
| Modifying agency | EG-GICUC |
| Description conventions | rda |
| 041 0# - LANGUAGE CODE | |
| Language code of text/sound track or separate title | eng |
| Language code of summary or abstract | eng |
| -- | ara |
| 049 ## - Acquisition Source | |
| Acquisition Source | Deposit |
| 082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER | |
| Classification number | 617.69 |
| 092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC) | |
| Classification number | 617.69 |
| Edition number | 21 |
| 097 ## - Degree | |
| Degree | M.Sc |
| 099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
| Local Call Number | Cai01.09.09.M.Sc.2025.Mo.M |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Authority record control number or standard number | Mohamed Hamdi Ragab Mohamed, |
| Preparation | preparation. |
| 245 10 - TITLE STATEMENT | |
| Title | Marginal fit of selective laser melting co- cr bar versus cast bar on mandibular edentulous casts with two implants supported over denture : |
| Remainder of title | an in vitro study / |
| Statement of responsibility, etc. | by Mohamed Hamdi Ragab Mohamed ; Supervisors Prof. Amal Fathy Tawfik Kaddah, Dr. Mohamed Amr El-Khashab. |
| 246 15 - VARYING FORM OF TITLE | |
| Title proper/short title | تقييم التلاؤم الهامشي في القضبان المصنوعة من الكوبالت والكروم بواسطة الليزر الانتقائي بالمقارنة مع القضبان المصنوعة من الكوبالت والكروم بالطريقة التقليدية في الأطقم المثبتة على غرستين في نموذج أدرد : |
| Remainder of title | دراسة مختبرية |
| 264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
| Date of production, publication, distribution, manufacture, or copyright notice | 2025. |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 126 pages : |
| Other physical details | illustrations ; |
| Dimensions | 25 cm. + |
| Accompanying material | CD. |
| 336 ## - CONTENT TYPE | |
| Content type term | text |
| Source | rda content |
| 337 ## - MEDIA TYPE | |
| Media type term | Unmediated |
| Source | rdamedia |
| 338 ## - CARRIER TYPE | |
| Carrier type term | volume |
| Source | rdacarrier |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Thesis (M.Sc)-Cairo University, 2025. |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE | |
| Bibliography, etc. note | Bibliography: pages 107-122. |
| 520 #3 - SUMMARY, ETC. | |
| Summary, etc. | Aim: This study aimed to evaluate and compare the marginal fit and flexure strength of Cobalt-<br/>Chromium customized bar fabricated with different manufacturing processes cast metal bar, and <br/>SLM metal bar utilizing USB-digital microscope. <br/>Methodology: A physical mandibular edentulous cast was digitized and imported into Blender for <br/>Dental software for virtual model creation. Digital implant planning involved placement of two <br/>parallel bone-level implants with a 14 mm inter-implant distance. The virtual model was 3D <br/>printed, and the printed model was embedded with two implant analogs. Scan abutments were <br/>attached, scanned, and imported into Exocad software for bar design. Twelve bars were fabricated: <br/>six using Selective Laser Melting (SLM) with Co-Cr alloy (Group I) and six using a combined <br/>digital-analog method (Group II). A USB-digital microscope was used to evaluate the marginal <br/>misfit at the implant-abutment interface. All samples were individually mounted in a custom-<br/>designed three-point bend fixture with a 20-mm span. Flexural testing was conducted using a <br/>computer-controlled universal testing machine equipped with a 5 kN load cell. Using the Shapiro-<br/>Wilk and Kolmogorov-Smirnov tests, the data's normality was assessed. <br/>Results: Paired t-tests demonstrated significantly higher marginal fit values for cast frameworks <br/>compared to 3D-printed counterparts on buccal (56.05±7.65 µm vs. 34.19±6.03 µm, p=0.003) and <br/>overall surfaces (50.0±2.62 µm vs. 39.93±4.71 µm, p=0.002). While a trend towards higher fit was <br/>observed for cast frameworks on the proximal surface (54.39±8.25 µm vs. 45.17±7.62 µm, p=0.08), <br/>it did not reach statistical significance. Repeated Measures ANOVA revealed significant surface-<br/>related variations in marginal fit within both groups. In the cast group, the lingual surface exhibited <br/>the poorest fit (39.55±4.94 μm), while in the SLM group, the buccal surface demonstrated the least <br/>favorable fit (34.19±6.03 μm). Flexural strength was significantly higher in the cast group (1448.4 ± <br/>45.83 MPa) compared to the SLM group (1212.7 ± 26.67 MPa) (p=0.0003), with a mean difference <br/>of 235.71 ± 39.92 MPa, as determined by a paired t-test. <br/>Conclusion: This study demonstrated that both SLM and cast Co-Cr bars exhibited clinically <br/>acceptable marginal misfit. However, SLM-fabricated bars demonstrated superior marginal fit at the <br/>implant-abutment interface in comparison to cast bars. These findings highlight the potential <br/>advantages of SLM technology in achieving high-precision and customized bar designs. SLM <br/>technology offers advancements in precision and customization, cast Co-Cr bars may exhibit <br/>greater flexural strength due to their microstructural characteristics, manufacturing processes, and <br/>stress distribution properties. |
| 520 #3 - SUMMARY, ETC. | |
| Summary, etc. | تقييم التلاؤم الهامشي في القضبان المصنوعة من الكوبالت والكروم بواسطة الليزر الانتقائي بالمقارنة مع القضبان المصنوعة من<br/>الكوبالت والكروم بالطريقة التقليدية في الأطقم المثبتة على غرستين في نموذج أدرد )دراسة مختبرية(<br/>الهدف من إجراء البحث:<br/>أجريت هذه الدراسة لتقييم التلاؤم الهامشي في القضبان المصنوعة من الكوبالت والكروم بواسطة الليزر الانتقائي بالمقارنة مع<br/>القضبان المصنوعة من الكوبالت والكروم بالطريقة التقليدية في الأطقم المثبتة على غرستين في نموذج أدرد في دراسة مختبرية .<br/>الطرق البحثية والاجراءات العلمية:<br/>الغرض من هذه الدراسة كان تقييم ومقارنة التلاؤم الهامشي وقوة الانثناء للقضبان المصممة والمنفذة رقمياً من سبائك الكوبالت<br/>الكروم كوبلت للأسنان المتحركة فوق الدعامات باستخدام طريقتين: الصب التقليدي والطباعة ثلاثية الأبعاد بالليزر الانتقائي،<br/>استخدمت الدراسة نموذجا ثلاثي الأبعاد للفك السفلي مطبوعا ثلاثي الأبعاد وصنعت ۱۲ قضب الذي يربط بين غرسات الأسنان،<br/>ستة في كل مجموعة . تم رقمنة نموذج فكي بدون أسنان وتم استيراده إلى برنامج Blender for Dental لإنشاء نموذج افتراضي.<br/>تضمن التخطيط الغرسي الرقمي وضع زرعتين على مستوى العظم بشكل متوازي بمسافة 14 ملم بينهما. وتم طباعة النموذج<br/>الافتراضي ثلاثي الأبعاد، وتم دمج النموذجين الغرسيين مطبوعين ثلاثي الأبعاد في النموذج. وتم تركيب أبراج المسح الضوئي،<br/>ومسحها ضوئيا،ً واستيرادها إلى برنامج Exocad لتصميم القضبان. تم تصنيع اثني عشر قضبان اً: ستة بالليزر الانتقائي ) SLM )<br/>مع سبيكة الكوبالت والكروم )المجموعة الأولى( وستة باستخدام طريقة رقمية تشبيهية مجتمعة )المجموعة الثانية(. تم استخدام -<br/>مجهر رقمي لتقييم الملاءمة الهامشية عند واجهة الغرسة. وتم تقييم توزيع البيانات الطبيعي باستخدام اختباري Shapiro-Wilk و<br/>Kolmogorov-Smirnov<br/>أظهرت الدراسة النتائج الاتية:<br/>أظهرت النتائج أن كلا من الليزر الانتقائي والصب التقليدي أنتجا قضبان ذات تلاؤم هامشي مقبول سريريا ,ومع ذلك أظهرت تقنية<br/>الليزر الانتقائي اكث ر تلاؤم ا داخلي ا عند واجهة الدعامة بالغرسة مقارنة بالصب التقليدي. في حين أن الصب التقليدي قد يوفر مزايا<br/>في قوة الانثناء بسبب خصائص المادة .<br/>من خلال نتائج الدراسة يمكن استنتاج الآتى:<br/>يستنتج من هذه الدراسة أن كلا من الطريقتين لهما إمكانيات في تصنيع القضبان، وتحتاج مزيد من الأبحاث لتحديد النهج الأمثل<br/>بناءً على المتطلبات السريرية والميكانيكية المحددة . |
| 530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
| Issues CD | Issues also as CD. |
| 546 ## - LANGUAGE NOTE | |
| Text Language | Text in English and abstract in Arabic & English. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Prosthodontics |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | إستعاضات الأسنان |
| 653 #1 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Cobalt Chromium |
| -- | dental Implant |
| -- | 3D printing |
| -- | SLM |
| -- | bar |
| -- | casting |
| -- | Internal fit |
| -- | Flexure strength |
| -- | الكوبالت والكروم |
| -- | زرع الأسنان |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Amal Fathy Tawfik Kaddah |
| Relator term | thesis advisor. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Mohamed Amr El-Khashab |
| Relator term | thesis advisor. |
| 900 ## - Thesis Information | |
| Grant date | 01-01-2025 |
| Supervisory body | Amal Fathy Tawfik Kaddah |
| -- | Mohamed Amr El-Khashab |
| Universities | Cairo University |
| Faculties | Faculty of Dentistry |
| Department | Department of Prosthodontics |
| 905 ## - Cataloger and Reviser Names | |
| Cataloger Name | Shimaa |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Thesis |
| Edition | 21 |
| Suppress in OPAC | No |
| Source of classification or shelving scheme | Home library | Current library | Date acquired | Inventory number | Full call number | Barcode | Date last seen | Effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 13.12.2025 | 92771 | Cai01.09.09.M.Sc.2025.Mo.M | 01010110092771000 | 12.12.2025 | 12.12.2025 | Thesis |