Marginal accuracy of ultra-translucent monolithic zirconia and machinable resin composite laminate veneers versus machinable lithium disilicate veneers using two different milling protocols : (Record no. 176662)

MARC details
000 -LEADER
fixed length control field 10303namaa22004331i 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GICUC
005 - أخر تعامل مع التسجيلة
control field 20251213124125.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 251213s2024 uaa|||frm||| 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloguing agency EG-GICUC
Language of cataloging eng
Transcribing agency EG-GICUC
Modifying agency EG-GICUC
Description conventions rda
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
Language code of summary or abstract eng
-- ara
049 ## - Acquisition Source
Acquisition Source Deposit
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 617.69
092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC)
Classification number 617.69
Edition number 21
097 ## - Degree
Degree M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Local Call Number Cai01.09.09.M.Sc.2024.Ne.M
100 0# - MAIN ENTRY--PERSONAL NAME
Authority record control number or standard number Nessma Mostafa Abdelkader Ahmed,
Preparation preparation.
245 10 - TITLE STATEMENT
Title Marginal accuracy of ultra-translucent monolithic zirconia and machinable resin composite laminate veneers versus machinable lithium disilicate veneers using two different milling protocols :
Remainder of title an in vitro study /
Statement of responsibility, etc. by Nessma Mostafa Abdelkader Ahmed ; Supervisors Prof. Dr. Hany Halim Nasr, Dr. Sama Nagy Kotb.
246 15 - VARYING FORM OF TITLE
Title proper/short title الإطباق الحافي للقشور التجميليه المصنعه من زيركونيا فائقة الشفافيه و الكومبوزيت المميكن مقارنة بالليثيوم دايسليكات المميكن باستخدام طريقتين مختلفتين للخرط :
Remainder of title دراسه معملية
264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice 2024.
300 ## - PHYSICAL DESCRIPTION
Extent 141 pages :
Other physical details illustrations ;
Dimensions 25 cm. +
Accompanying material CD.
336 ## - CONTENT TYPE
Content type term text
Source rda content
337 ## - MEDIA TYPE
Media type term Unmediated
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc)-Cairo University, 2024
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography: pages 124-139.
520 #3 - SUMMARY, ETC.
Summary, etc. Statement of the problem: The need of an aesthetic strong restoration that can be obtained with minimal <br/>tooth preparation for more conservative operation is increasing. Zirconia ceramic restorations can show <br/>sufficient strength but the main problem was zirconia’s opacity. So, for a number of years lithium <br/>disilicate ceramic laminate veneers were used but their main disadvantage was the great difficulty to be <br/>milled in ultrathin thicknesses with complete marginal adaptation. Also, composite material has high <br/>esthetic properties, but was more time consuming. The invention of ultra-translucent zirconia ceramics <br/>enhanced their esthetic and optical properties. As well with the introduction of machinable composite <br/>and the advantage of high bonding strength so they can be an appealing alternative for lithium disilicate <br/>restoration with their abilities to be milled in very thin thicknesses providing satisfactory marginal <br/>adaptation and esthetic properties. <br/>Aim: to investigate whether CAD/CAM Ultra-translucent zirconia and machinable composite have <br/>marginal adaptation comparable to that of lithium disilicate glass-ceramic when milled into laminate <br/>veneers using two different milling protocols. <br/>Methods: a typodont maxillary central incisor was prepared for laminate veneers butt-joint incisal <br/>preparation and 0.4 mm chamfer finish line to receive 36 laminate veneers (n=12) constructed from; <br/>group L: Lithium disilicate (IPS e.max CAD), group Z: Ultra translucent zirconia (UTML KATANA), <br/>and group C: Machinable composite ( Brilliant Crios). Each group was subdivided according to milling <br/>protocol into 2 subgroups (n=6), fast and normal milling protocols. Direct scanning with intraoral <br/>scanner “Medit i500” was done to obtain virtual image for the prepared typodont tooth. For CAD-CAM <br/>process, Exocad software was used for designing of the required laminate veneers and 5-axis milling <br/>machine was used for manufacturing. After milling each laminate was measured for vertical marginal <br/> gap under digital stereomicroscope at magnification X45. Measurements were done along all margins of <br/>each veneer (mesial, distal, incisal and cervical) at 3 points for each surface. Each measurement was <br/>repeated three times. The mean vertical marginal gap was calculated. The mean and standard deviation <br/>values were calculated for different measurements. One-Way Anova followed by post hoc test was used <br/>to compare between more than two groups. Paired t-test was used to compare between two groups in <br/>related samples. <br/>Results: Regarding normal milling protocol, there was statistical significant difference between <br/>materials (P-value = 0.01*). Ultra-translucent zirconia showed the lowest mean marginal gap (13.3 ±1.83 <br/>µm) while lithium disilicate and machinable composite had no statistical significant difference with <br/>mean marginal gaps (15.2 ±1.83 µm) and (15.2 ±3.33µm) respectively. As for fast milling protocol, there <br/>was statistical significant difference between materials with (P-value = 0.012*). Machinable composite <br/>showed the lowest mean marginal gap (12.05 ± 3 µm), while there was no statistical significant <br/>difference between ultra-translucent zirconia (13.97 ± 1.47 µm) compared to both lithium disilicate <br/>(14.92 ± 2.3 µm) and machinable composite materials. Finally there was no statistically significant <br/>difference between fast and normal milling protocols except for machinable composite. <br/>Conclusion: Despite the fact that there were statistically significant differences in marginal gaps <br/>between the three materials with both fast and normal milling speeds, all fall within the clinically <br/>accepted range. Ultra translucent zirconia and machinable composite can be considered as a great <br/>revolution in laminate veneers fabrication, also as substitutes for the lithium disilicate veneers. Ultra <br/>translucent zirconia laminates exhibited the lowest marginal gaps in normal milling while, machinable <br/>composite exhibited the lowest marginal gaps in fast milling protocol. Also, Fast milling can substitute <br/>normal milling protocol.
520 #3 - SUMMARY, ETC.
Summary, etc. يهدف هذا البحث الى التحقق من الاطباق الحافي للقشور التجميلية المصنعة من الزركونيا فائقة الشفافية CAD/CAM و الكومبوزيت المميكن مقارنة بالليثيوم دايسيليكات المميكن باستخدام بروتوكولين مختلفين للخرط.<br/>تم تجهيز سن من الأكريليك لاستقبال القشور التجميليه بعد ذلك تم اخذ مقاس رقمي السن المجهز باستخدام الماسح الضوئي الداخل للفم "Medit i500" للحصول على صورة افتراضية. تم تصميم القشرة التجميليه باستخدام برنامج Exocad 2.3 Matera. ثم تم تصنيع ٣٦ قشرة تجييلية من ٣ مجموعات وفقًا للموادالمستخمة في فالتصنيع و هي الليثيوم دايسليكات المميكن (IPS e.max CAD) و زيركونيا فائقة الشفافيه (UTML KATANA)، و الكومبوزيت المميكن (Brilliant Crios) . تم تقسيم كل مجموعة وفقًا لبروتوكول الخرط إلى مجموعتين، بروتوكول الخرط السريع والعادي باستخدام آلة الخرط ذات ٥ محاور "MC X5". بعد الخرط، تم قياس الإطباق الحافي العمودي على طول جميع الحواف لكل قشرة تجميلية عند ٣ نقاط لكل سطح تحت المجهر المجسم الرقمي عند التكبير ٤٥ X. ثم تم حساب متوسط الفجوة الحافية العمودية. تم استخدام تحليل التباين الأحادي (One-Way Anova) متبوعًا باختبار (post hoc test ) للمقارنة بين أكثر من مجموعتين. و تم استخدام اختبار ( t-test ) للمقارنة بين مجموعتين في العينات ذات الصلة.<br/>وجد ان: بعد بروتوكول الخرط العادي، كان هناك فرق ذو دلالة إحصائية بين المواد. أظهرت الزركونيا فائقة الشفافية أدنى للفجوة الهامشية بينما لم يكن لديسيليكات الليثيوم و الكومبوزيت المميكن أي دلالة إحصائية. بعد بروتوكول الخرط السريع، كان هناك فرق ذو دلالة إحصائية بين المواد. أظهر الكومبوزيت المميكن أدنى قيمة للفجوة الهامشية متوسطة، في حين لم يكن هناك فرق إحصائي كبير بين الزركونيا فائقة الشفافية مقارنة بكل من ديسيليكات الليثيوم و الكومبوزيت المميكن. وأخيرا لم يكن هناك فرق ذو دلالة إحصائية بين بروتوكولات الخرط السريعة والعادية باستثناء الكومبوزيت المميكن.<br/>الاستنتاج: الخرط السريع يمكن أن يحل محل بروتوكول الخرط العادي. على الرغم من وجود فروق ذات دلالة إحصائية في الفجوات الهامشية بين المواد الثلاث مع كل من سرعات الخرط السريعة والعادية، إلا أن جميعها تقع ضمن النطاق المقبول سريريًا <90 ميكرومتر. زركونيا فائقة الشفافية مع طحن عادي وفجوات هامشية مماثلة للكومبوزيت المميكن في الطحن السريع. وبالتالي، يمكن اعتباره ثورة عظيمة في تصنيع القشور التجميليه بقوته العالية. يمكن أيضًا الكومبوزيت المميكن أن يحل محل القشرة الصفائحية من ديسيليكات الليثيوم خاصة في بروتوكول الطحن السريع، وذلك نظرًا لثبات الحافة العالية مقارنة بثنائي سيليكات الليثيوم
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Issues CD Issues also as CD.
546 ## - LANGUAGE NOTE
Text Language Text in English and abstract in Arabic & English.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prosthodontics
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element استعاضات الاسنان
653 #1 - INDEX TERM--UNCONTROLLED
Uncontrolled term Laminate veneers
-- Ultra translucent zirconia
-- machinable composite
-- marginal accuracy
-- marginal gaps
-- milling protocol
-- قشور صفائحية
-- ثنائي سيليكات الليثيوم
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hany Halim Nasr
Relator term thesis advisor.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sama Nagy Kotb
Relator term thesis advisor.
900 ## - Thesis Information
Grant date 01-01-2025
Supervisory body Hany Halim Nasr
-- Sama Nagy Kotb
Universities Cairo University
Faculties Faculty of Dentistry
Department Department of Prosthodontics
905 ## - Cataloger and Reviser Names
Cataloger Name Shimaa
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Edition 21
Suppress in OPAC No
Holdings
Source of classification or shelving scheme Home library Current library Date acquired Inventory number Full call number Barcode Date last seen Effective from Koha item type
Dewey Decimal Classification المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 13.12.2025 92773 Cai01.09.09.M.Sc.2024.Ne.M 01010110092773000 12.12.2025 13.12.2025 Thesis
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library