Is single-injection digital nerve block technique effective in finger surgeries done under local anaesthesia? / (Record no. 177558)

MARC details
000 -LEADER
fixed length control field 09180namaa22004451i 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GICUC
005 - أخر تعامل مع التسجيلة
control field 20260120124545.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 260110s2025 ua a|||frm||| 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloguing agency EG-GICUC
Language of cataloging eng
Transcribing agency EG-GICUC
Modifying agency EG-GICUC
Description conventions rda
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
Language code of summary or abstract eng
-- ara
049 ## - Acquisition Source
Acquisition Source Deposit
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 616.723
092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC)
Classification number 616.723
Edition number 21
097 ## - Degree
Degree M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Local Call Number Cai01.11.25.M.Sc.2025.Ah.I
100 0# - MAIN ENTRY--PERSONAL NAME
Authority record control number or standard number Ahmed Naser Hanafi Mahmoud,
Preparation preparation.
245 10 - TITLE STATEMENT
Title Is single-injection digital nerve block technique effective in finger surgeries done under local anaesthesia? /
Statement of responsibility, etc. by Ahmed Naser Hanafi Mahmoud ; Supervision Prof. Dr. Yasser ElSafoury, Prof. Dr. Mostafa Ezzat, Dr. Mohamed Ahmed Mohamed Ibrahim.
246 15 - VARYING FORM OF TITLE
Title proper/short title هل تكون تقنية التخدير للعصب الإصبعى بحَقنة واحدة فعالة فى جراحات الأصابع التى تتم تحت التخدير الموضعى ؟
264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice 2025.
300 ## - PHYSICAL DESCRIPTION
Extent 90 pages :
Other physical details illustrations ;
Dimensions 25 cm. +
Accompanying material CD.
336 ## - CONTENT TYPE
Content type term text
Source rda content
337 ## - MEDIA TYPE
Media type term Unmediated
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc)-Cairo University, 2025.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography: pages 84-90.
520 #3 - SUMMARY, ETC.
Summary, etc. Back ground: The increasing rate of finger surgeries, necessitates the use of the<br/>wide-awake approach to cope with higher flow of patients, posing a challenge on hand<br/>surgeons to choose the most appropriate DNB with highest efficacy & least<br/>complication for different types of finger surgeries. <br/>Objective: to assess efficacy and pain associated with the subcutaneous DNB for<br/>different types of finger surgeries. <br/>Patients & Methods: A group of 51 participants age range (16-65 years), with finger<br/>lesions, recruited from the ER and outpatient setting. All had their operations done<br/>under a single injection SCB injected at midline of the proximal digital crease, with<br/>SC infiltration of 3-5 ml of o.5% bupivacaine. Testing for success was done by<br/>pinprick testing at 5 min intervals and NRS score was used for measuring injection<br/>and procedure pain scores, while surgeon satisfaction was measured on a 1 to 10<br/>scale. <br/>Results: Among the 51 participants undergoing the SCB we had an 86.3% success<br/>rate. Mean injection pain of 3.17±1.7, mean procedure pain 0.84 1.5. The mean TTOA<br/>was 11.3±4.02 minutes, while mean DOP was 20.08±8.6 minutes. Location of the<br/>lesion had a significant impact on failure rate, PP, moderate SS and injection pain, the<br/>former 3 were highest among proximal dorsal regions, while the latter was highest<br/>among proximal volar ones. Ring fingers had higher injection pain while thumb and<br/>little finger had higher failure rate. Higher volume of anaesthetic was associated with<br/>lower procedure pain and shorter TTOA. Success rate was higher among chronic<br/>lesions but results were insignificant. Bony lesions although having a relatively low<br/>injection pain, they had high failure rate and PP level with low level of satisfaction<br/>whereas skin lesions had 100% success rate but the lowest level of surgeon<br/>satisfaction. <br/>Conclusion: The SCB is a safe, efficient DNB, that should be practically integrated<br/>into the everyday practice of hand surgeons, replacing traditional blocks. Surgeons<br/>should apply fine adjustments in block administration on a case-to-case basis<br/>according to modifiable risk factors identified to ensure maximal efficacy and least<br/>pain associated with the block
520 #3 - SUMMARY, ETC.
Summary, etc. ﻳﺘﻄﻠﺐ ﺗﺰﺍﻳﺪ ﻣﻌﺪﻝ ﺟﺮﺍﺣﺎﺕ ﺍﻷﺻﺎﺑﻊ ﺍﺳﺘﺨﺪﺍﻡ ﻧﻬﺞ ﺍﻟﻴﻘﻈﺔ ﺍﻟﺘﺎﻣﺔ ﻟﻠﺘﻌﺎﻣﻞ ﻣﻊ ﻋﺪﺩ ﺃﻛﺒﺮ ﻣﻦ <br/>ﺍﻟﻤﺮﺿﻰ، ﻣﻤﺎﻳُﺸﻜﻞ ﺗﺤﺪﻳًﺎ ﻟﺠﺮﺍﺣﻲ ﺍﻟﻴﺪ ﻓﻲ ﺍﺧﺘﻴﺎﺭ ﺃﻧﺴﺐ ﻁﺮﻳﻘﺔ ﻟﺘﺨﺪﻳﺮ ﺍﻟﻌﺼﺐ ﺍﻻﺻﺒﻌﻰ ﺫﺍﺕ <br/> ﺍﻟﻔﻌﺎﻟﻴﺔ ﺍﻟﻌﺎﻟﻴﺔ ﻭﺍﻷﻗﻞ ﻣﻀﺎﻋﻔﺎﺕ ﻟﻤﺨﺘﻠﻒ ﺃﻧﻮﺍﻉ ﺟﺮﺍﺣﺎﺕ ﺍﻷﺻﺎﺑﻊ.<br/>ﻣﺠﻤﻮﻋﺔ ﻣﻦ 51 ﻣﺸﺎ ﺎ ﺗﺘﺮﺍﻭﺡ ﺃﻋﻤﺎﺭﻫﻢ ﺑﻴﻦ <br/><br/>ً<br/><br/>ﺭﻛ 16 ﻭ65 ﺎ، ﻳﻌﺎﻧﻮﻥ ﻣﻦ ﺇﺻﺎﺑﺎﺕ ﻓﻲ ﺍﻷﺻﺎﺑﻊ، <br/><br/>ً<br/><br/>ﻋﺎﻣ<br/>ﺗﻢ ﺗﺠﻨﻴﺪﻫﻢ ﻣﻦ ﻗﺴﻢ ﺍﻟﻄﻮﺍﺭﺉ ﻭﺍﻟﻌﻴﺎﺩﺍﺕ ﺍﻟﺨﺎﺭﺟﻴﺔ.ﺃُﺟﺮﻳﺖ ﻋﻤﻠﻴﺎﺗﻬﻢ ﺟﻤﻴﻌًﺎ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺣﻘﻨﺔ ﻭﺍﺣﺪﺓ <br/>ﻣﻦ ﺗﺨﺪﻳﺮ ﺍﻟﻌﺼﺐ ﺍﻻﺻﺒﻌﻰ ﻋﻦ ﻁﺮﻳﻖ ﺍﻟﺤﻘﻦ ﺗﺤﺖ ﺍﻟﺠﻠﺪ ﻓﻲ ﻣﻨﺘﺼﻒ ﺛﻨﻴﺔ ﺍﻹﺻﺒﻊ ﺍﻟﻘﺮﻳﺒﺔ، ﻣﻊ <br/>ﺣﻘﻦ 3-5 ﻣﻞ ﻣﻦ ﺑﻮﺑﻴﻔﺎﻛﻴﻦ ﺑﺘﺮﻛﻴﺰ 0.5%. ﺗﻢ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻨﺠﺎﺡ ﻋﻦ ﻁﺮﻳﻖ ﺍﺧﺘﺒﺎﺭ ﻭﺧﺰ ﺍﻹﺑﺮﺓ <br/> ﻟﻘﻴﺎﺱ ﺩﺭﺟﺎﺕ ﺃﻟﻢ ﺍﻟﺤﻘﻦ ﻭﺍﻹﺟﺮﺍء NRSﺑﻔﺎﺻﻞ 5 ﺩﻗﺎﺋﻖ، ﻭﺍﺳﺘُﺨﺪﻡ ﺍﻟﻤﻘﻴﺎﺱ ﺍﻟﺮﻗﻤﻰ ﻟﻸﻟﻢ <br/> ﺍﻟﺠﺮﺍﺣﻰ، ﺑﻴﻨﻤﺎ ﺗﻢ ﻗﻴﺎﺱ ﺭﺿﺎ ﺍﻟﺠﺮﺍﺡ ﻋﻠﻰ ﻣﻘﻴﺎﺱ ﻣﻦ 1 ﺇﻟﻰ 10.<br/> ﻣﻦ ﺑﻴﻦ 51 ﻣﺸﺎﺭًﻛﺎ ﺧﻀﻌﻮﺍ ﻟﻌﻤﻠﻴﺔ ﺗﺨﺪﻳﺮ ﺍﻻﺻﺒﻊ ﺑﺤﻘﻨﺔ ﻭﺍﺣﺪﺓ ﺗﺤﺖ ﺍﻟﺠﻠﺪ، ﻛﺎﻥ ﻣﻌﺪﻝ ﺍﻟﻨﺠﺎﺡ <br/>. ﻛﺎﻥ ﻣﺘﻮﺳﻂ ﻭﻗﺖ 1.5±0.84، ﻣﺘﻮﺳﻂ ﺃﻟﻢ ﺍﻹﺟﺮﺍء1.7±86.33.17%. ﻣﺘﻮﺳﻂ ﺍﻟﻢ ﺍﻟﺤﻘﻦ <br/> ﺩﻗﻴﻘﺔ.8.6±20.08ﺩﻗﻴﻘﺔ، ﺑﻴﻨﻤﺎ ﻛﺎﻥ ﻣﺘﻮﺳﻂ ﻭﻗﺖ ﺍﻟﺤﻘﻦ 4.02±11.3ﺍﻟﺤﻘﻦ <br/> ﻛﺎﻥ ﻟﻤﻮﻗﻊ ﺍﻻﺻﺎﺑﺔ ﺗﺄﺛﻴﺮ ﻛﺒﻴﺮ ﻋﻠﻰ ﻣﻌﺪﻝ ﺍﻟﻔﺸﻞ، ﻭﺍﻻﻟﻢ ﺍﻟﺠﺮﺍﺣﻰ، ﻭ ﺭﺿﺎ ﺍﻟﺠﺮﺍﺡ ﺍﻟﻤﻌﺘﺪﻝ، <br/>ﻭﺃﻟﻢ ﺍﻟﺤﻘﻦ. ﻛﺎﻧﺖ ﺍﻟﺜﻼﺛﺔ ﺍﻷﻭﻟﻰ ﻫﻲ ﺍﻷﻋﻠﻰ ﺑﻴﻦ ﺍﻟﻤﻨﺎﻁﻖ ﺍﻟﻈﻬﺮﻳﺔ ﺍﻟﻘﺮﻳﺒﺔ، ﺑﻴﻨﻤﺎ ﻛﺎﻧﺖ ﺍﻷﺧﻴﺮﺓ <br/>ﺍﻷﻋﻠﻰ ﺑﻴﻦ ﺍﻟﻤﻨﺎﻁﻖ ﺍﻟﺮﺍﺣﻴﺔ ﺍﻟﻘﺮﻳﺒﺔ. ﻛﺎﻥ ﺃﻟﻢ ﺍﻟﺤﻘﻦ ﺃﻋﻠﻰ ﻓﻲ ﺍﻟﺒﻨﺼﺮ، ﺑﻴﻨﻤﺎ ﻛﺎﻥ ﻣﻌﺪﻝ ﺍﻟﻔﺸﻞ <br/>ﺃﻋﻠﻰ ﻓﻲ ﺍﻹﺑﻬﺎﻡ ﻭﺍﻟﺨﻨﺼﺮ. ﺍﺭﺗﺒﻂ ﺣﺠﻢ ﺍﻟﺘﺨﺪﻳﺮ ﺍﻷﻛﺒﺮ ﺑﺄﻟﻢ ﺃﻗﻞ ﻓﻲ ﺍﻹﺟﺮﺍء ﻭﻭﻗﺖ ﻟﺘﺤﻘﻴﻖ <br/>ﺍﻟﺘﺨﺪﻳﺮ ﺃﻗﺼﺮ. ﻛﺎﻥ ﻣﻌﺪﻝ ﺍﻟﻨﺠﺎﺡ ﺃﻋﻠﻰ ﺑﻴﻦ ﺍﻹﺻﺎﺑﺎﺕ ﺍﻟﻐﻴﺮ ﻁﺎﺭﺋﺔ، ﻟﻜﻦ ﺍﻟﻨﺘﺎﺋﺞ ﻛﺎﻧﺖ ﺿﺌﻴﻠﺔ. <br/>ﺎ ﻣﻨﺨﻔًﻀﺎ ﻧﺴﺒﻴًﺎ ﻋﻨﺪ ﺍﻟﺤﻘﻦ، ﺇﻻ ﺃﻥ ﻣﻌﺪﻝ ﻓﺸﻠﻬﺎ <br/>ﻋﻠﻰ ﺍﻟﺮﻏﻢ ﻣﻦ ﺃﻥ ﺍﻹﺻﺎﺑﺎﺕ ﺍﻟﻌﻈﻤﻴﺔﺗُﺴﺒﺐ ﺃﻟﻤ<br/>ﻭﻣﺴﺘﻮﻯ ﺍﻻﻟﻢ ﺍﻟﺠﺮﺍﺣﻰ ﻓﻴﻬﺎ ﻣﺮﺗﻔﻌﺎﻥ، ﻣﻊ ﺍﻧﺨﻔﺎﺽ ﻣﺴﺘﻮﻯ ﺍﻟﺮﺿﺎ، ﺑﻴﻨﻤﺎ ﺣﻘﻘﺖ ﺍﻹﺻﺎﺑﺎﺕ <br/> ﺍﻟﺠﻠﺪﻳﺔ ﻣﻌﺪﻝ ﻧﺠﺎﺡ 100%، ﻟﻜﻦ ﻣﺴﺘﻮﻯ ﺭﺿﺎ ﺍﻟﺠﺮﺍﺡ ﻛﺎﻥ ﺍﻷﻗﻞ.<br/>ﻳُﻌﺪّ ﺣﻘﻦ ﺍﻟﻤﺨﺪﺭ ﺍﻟﻤﻮﺿﻌﻰ ﻟﺘﺨﺪﻳﺮ ﺍﻟﻌﺼﺐ ﺍﻻﺻﺒﻌﻰ ﺗﺤﺖ ﺍﻟﺠﻠﺪ ﺣﻘﻨًﺎ ﺟﺮﺍﺣﻴًﺎ ﺁﻣﻨًﺎ ﻭﻓﻌﺎﻻ<br/>ﻭﻳﻨﺒﻐﻲ ﺩﻣﺠﻪ ﻋﻤﻠﻴًﺎ ﻓﻲ ﺍﻟﻤﻤﺎﺭﺳﺔ ﺍﻟﻌﻤﻠﻴﺔ ﻟﺠﺮﺍﺣﻲ ﺍﻟﻴﺪ، ﻟﻴﺤﻞ ﻣﺤﻞ ﺍﻟﺘﺨﺪﻳﺮ ﺍﻟﺘﻘﻠﻴﺪﻱ. ﻳﺠﺐ ﻋﻠﻰ <br/>ﺍﻟﺠﺮﺍﺣﻴﻦ ﺇﺟﺮﺍء ﺗﻌﺪﻳﻼﺕ ﺩﻗﻴﻘﺔ ﻓﻲ ﺇﻋﻄﺎء ﺍﻟﺘﺨﺪﻳﺮ ﻋﻠﻰ ﺃﺳﺎﺱ ﻛﻞ ﺣﺎﻟﺔ ﻋﻠﻰ ﺣﺪﺓ، ﻭﻓﻘًﺎ ﻟﻌﻮﺍﻣﻞ <br/>ﺍﻟﺨﻄﺮ ﺍﻟﻘﺎﺑﻠﺔ ﻟﻠﺘﻌﺪﻳﻞ ﺍﻟﺘﻲ ﺗﻢ ﺗﺤﺪﻳﺪﻫﺎ، ﻟﻀﻤﺎﻥ ﺃﻗﺼﻰ ﻗﺪﺭ ﻣﻦ ﺍﻟﻔﻌﺎﻟﻴﺔ ﻭﺃﻗﻞ ﻗﺪﺭ ﻣﻦ ﺍﻷﻟﻢ <br/> ﺍﻟﻤﺼﺎﺣﺐ ﻟﻠﺘﺨﺪﻳﺮ.
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Issues CD Issues also as CD.
546 ## - LANGUAGE NOTE
Text Language Text in English and abstract in Arabic & English.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Orthopedics
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element طب العظام
653 #1 - INDEX TERM--UNCONTROLLED
Uncontrolled term Finger
-- Digital nerve block
-- Single injection
-- Subcutaneous
-- تقنية التخدير للعصب الإصبعى بحَقنة واحدة فعالة
-- تحت التخدير الموضعى
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Yasser ElSafoury
Relator term thesis advisor.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mostafa Ezzat
Relator term thesis advisor.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Ahmed Mohamed Ibrahim
Relator term thesis advisor.
900 ## - Thesis Information
Grant date 01-01-2025
Supervisory body Yasser ElSafoury
-- Mostafa Ezzat
-- Mohamed Ahmed Mohamed Ibrahim
Universities Cairo University
Faculties Faculty of Medicine
Department Department of Orthopedic Surgery
905 ## - Cataloger and Reviser Names
Cataloger Name Shimaa
Reviser Names Eman Ghareb
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Edition 21
Suppress in OPAC No
Holdings
Source of classification or shelving scheme Home library Current library Date acquired Inventory number Full call number Barcode Date last seen Effective from Koha item type
Dewey Decimal Classification المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 10.01.2026 93105 Cai01.11.25.M.Sc.2025.Ah.I 01010110093105000 10.01.2026 10.01.2026 Thesis
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library