Retention of mandibular implant supported overdentures using CM-LOC and locator attachment systems : (Record no. 177751)

MARC details
000 -LEADER
fixed length control field 05514namaa22004331i 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GICUC
005 - أخر تعامل مع التسجيلة
control field 20260121120259.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 260117s2020 ua a|||frm||| 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloguing agency EG-GICUC
Language of cataloging eng
Transcribing agency EG-GICUC
Modifying agency EG-GICUC
Description conventions rda
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
Language code of summary or abstract eng
-- ara
049 ## - Acquisition Source
Acquisition Source Deposit
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 617.69
092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC)
Classification number 617.69
Edition number 21
097 ## - Degree
Degree M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Local Call Number Cai01.09.09.M.Sc.2020.Om.R
100 0# - MAIN ENTRY--PERSONAL NAME
Authority record control number or standard number Omar Hashem Kamal Mohamed,
Preparation preparation.
245 10 - TITLE STATEMENT
Title Retention of mandibular implant supported overdentures using CM-LOC and locator attachment systems :
Remainder of title A randomized in vitro study /
Statement of responsibility, etc. by Omar Hashem Kamal Mohamed ; Supervisor Dr. Nouran Abd Al Naby, Dr. Nada Sherin El Khourazaty.
246 15 - VARYING FORM OF TITLE
Title proper/short title استبقاء الاطقم الكاملة المدعومة بغرسات فى الفك السفلى باستخدام Locator و CM-LOC من الوصلات المستخدمة لاستبقاء دراسة معملية
264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice 2020.
300 ## - PHYSICAL DESCRIPTION
Extent 101 pages :
Other physical details illustrations ;
Dimensions 25 cm. +
Accompanying material CD.
336 ## - CONTENT TYPE
Content type term text
Source rda content
337 ## - MEDIA TYPE
Media type term Unmediated
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.)-Cairo University, 2020.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography: pages 86-100.
520 #3 - SUMMARY, ETC.
Summary, etc. Aim: Implant supported overdentures have proved to be a better treatment option compared to <br/>conventional dentures in treating edentulous jaws. The present study was carried out to compare the <br/>retention of two different types of attachments used to retain single implant supported mandibular <br/>overdenture using universal testing machine after mechanical aging that was done by chewing simulator. <br/>The two attachments used in this study were Locator and Cendres and Meteaux Locator (CM-LOC). <br/><br/> <br/><br/>Methodology: Ten epoxy resin models of completely edentulous mandible were constructed and <br/>prepared to receive a single implant in the midline area. Ten overdentures were constructed with steel <br/>rods fixed to the denture using auto polymerized acrylic resin at the geometric center, two attachment <br/>systems; Locator attachmrent with nylon matrix and Cendres &Meteaux Locator (CM-LOC) with a <br/>PEKK matrix were investigated, with each type of attachment, the pickup procedure consisted of <br/>attaching matrix to the fitting surface of the denture with self-cure acrylic resin. All of the overdentures <br/>were subjected to different chewing cycles 500 cycles = (3 month), 1000 cycles = (6 month), 1500 <br/>cycles = (9 month) and 2000 cycles = (12 month) , then retention was evaluated using universal testing <br/>machine.. <br/>Results: The Locator attachment have shown a decrease in retention when subjected to different <br/>chewing cycles (p=0.001), with pairwise comparison showing a statistically significant difference <br/>between baseline and 2000 cycles ( p=0.011), between 500 cycle and 2000 cycle ( p=0.024). <br/>While for the CM-LOC group there was a decrease in retention when subjected to 500, 1000, 1500 <br/>cylces ( p=0.001), and with a slight increase in retention after 2000 cycles. With pairwise comparisons <br/>there was statistically significant difference at 500 cycles = 3 month and 1500 cycles (9 month). <br/>Conclusion: Within in limitation of the present study in vitro study it can be concluded that both the <br/>Locator and CM-LOC attachment have shown acceptable retention values to support single implant <br/>mandibular retained overdentures. However both attachments have shown a decrease in retention when <br/>subjected to different chewing cycles , The CM-LOC attachment has shown significant better retention <br/>when compared to Locator attachment after 500 cycles .
520 #3 - SUMMARY, ETC.
Summary, etc. اجريت هذه الرسالة لمقارنة القدرة الاحتياطية لنوعين مختلفين من الملحقات المستخدمة للاحتفاظ في الاطقم المدعومة بالزرعة الواحدة بواسطة ألة اختبار علمية بعد التقدم الميكانيكي الذي تم بواسطة جهاز محاكاة المضغ.<br/>بينما كانت مجموعة التدخل هي مجموعة CM-LOC وكانت مجموعة التحكم هيLOCATOR <br/>تم بناء نموذج ايبوكسي للفك السفلي عديم الاسنان تماماً وتجهيزه لتلقي زرعة واحدة في منطقة خط الوسط. تم بناء عشرة أطقم مفردة خمسة تحتوي على مصفوفة من النايلون وخمسة أخرى تحتوي على مصفوفة من PEEK<br/>ثم يتم قياس قيم الاحتفاظ عند خط الاساس باستخدام ألة اختبارعالمية ثم تعرضت الأطقم في كل مجموعة لدورات مضغ مختلفة 500 و 1000 و 1500 و 2000 دورة. تم قياس الاستبقاء طوال هذه الدورات لكلا المجموعتين.
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Issues CD Issues also as CD.
546 ## - LANGUAGE NOTE
Text Language Text in English and abstract in Arabic & English.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prosthodontics
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element الاستعاضه الصناعية
653 #1 - INDEX TERM--UNCONTROLLED
Uncontrolled term Retention Of Mandibular Implant
-- Supported Overdentures
-- CM-LOC And Locator
-- Attachment Systems
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nouran Abd Al Naby
Relator term thesis advisor.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nada Sherin El Khourazaty
Relator term thesis advisor.
900 ## - Thesis Information
Grant date 01-01-2020
Supervisory body Nouran Abd Al Naby
-- Nada Sherin El Khourazaty
Discussion body Noura Cheta
-- Marwa Thabet
Universities Cairo University
Faculties Faculty of Dentistry
Department Department of Prosthodontics
905 ## - Cataloger and Reviser Names
Cataloger Name Shimaa
Reviser Names Eman Ghareb
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Edition 21
Suppress in OPAC No
Holdings
Source of classification or shelving scheme Home library Current library Date acquired Inventory number Full call number Barcode Date last seen Effective from Koha item type
Dewey Decimal Classification المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 17.01.2026 93150 Cai01.09.09.M.Sc.2020.Om.R 01010110093150000 17.01.2026 17.01.2026 Thesis
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library