Implant survival in two-piece versus single-piece patient-specific titanium subperiosteal implants in atrophied edentulous mandibles : (Record no. 177754)

MARC details
000 -LEADER
fixed length control field 07761namaa22004451i 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GICUC
005 - أخر تعامل مع التسجيلة
control field 20260121120609.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 260117s2024 ua a|||frm||| 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloguing agency EG-GICUC
Language of cataloging eng
Transcribing agency EG-GICUC
Modifying agency EG-GICUC
Description conventions rda
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
Language code of summary or abstract eng
-- ara
049 ## - Acquisition Source
Acquisition Source Deposit
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 617.69
092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC)
Classification number 617.69
Edition number 21
097 ## - Degree
Degree Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Local Call Number Cai01.09.09.Ph.D.2024.Ma.I
100 0# - MAIN ENTRY--PERSONAL NAME
Authority record control number or standard number Mariam Ahmed Roshdy Ragab,
Preparation preparation.
245 10 - TITLE STATEMENT
Title Implant survival in two-piece versus single-piece patient-specific titanium subperiosteal implants in atrophied edentulous mandibles :
Remainder of title A combined finite element analysis and randomized clinical trial /
Statement of responsibility, etc. by Mariam Ahmed Roshdy Ragab ; Supervisors Prof. Dr. Mahmoud Mokhtar El Far, Prof. Dr. Maha Wagdy El Kerdawy, Prof. Dr. Adel Hamdy Abo El Fetouh.
246 15 - VARYING FORM OF TITLE
Title proper/short title معدل بقاء غرسات التيتانيوم تحت السمحاق المصنعة خصيصاً للمريض و مكونة من قطعة أو قطعتين لإستخدامها في الفك السفلي الضامر :
Remainder of title تجربة سريرية عشوائية مع تحليل العناصر المنتهية
264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice 2024.
300 ## - PHYSICAL DESCRIPTION
Extent 148 pages :
Other physical details illustrations ;
Dimensions 25 cm. +
Accompanying material CD.
336 ## - CONTENT TYPE
Content type term text
Source rda content
337 ## - MEDIA TYPE
Media type term Unmediated
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.)-Cairo University, 2024.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography: pages 136-142.
520 #3 - SUMMARY, ETC.
Summary, etc. Aim: The aim of the clinical section of this study was to investigate the difference between single-piece and staged two-piece patient-specific titanium mandibular subperiosteal implants (SPIs) in terms of implant survival and soft tissue dehiscence. Concomitantly, a three-dimensional finite element analysis (3D FEA) study was conducted to explore the differences in biomechanical behavior of the aforementioned SPI designs. <br/>Materials and methods: The 3D FEA study involved two simulations: Simulation 1 represented oblique right-side loading representing the side that harbored the single-piece SPI framework, while simulation 2 represented oblique left-side loading representing the side that harbored the two-piece SPI framework. Peri-implant stresses, von Mises stress in frameworks, fixation screws, and overlying prosthesis as well as total deformation of fixation screws were assessed. The clinical study included 5 male patients with a severely atrophied mandible. They all received a unilateral single-piece SPI on one side, and a unilateral staged two-piece SPI on the contralateral side and then received a cement-retained prosthesis with a short cantilever on a total of 4 upstanding abutments. Implant survival and soft tissue dehiscence were the outcomes recorded after 3, 6 and 12 months. <br/>Results: 3D FEA results revealed that stress values at the peri-implant bone, on fixation screws as well as the total deformation of fixation screws were fairly comparable for both SPI designs. However, the stress values recorded for the framework in simulation 2 were considerably greater than those recorded for the framework in simulation 1. Clinical results revealed 100 % survival rate for the single-piece SPIs throughout the follow up period. For the staged two-piece SPIs, the survival rate was 80 % at the end of the 12-month follow-up period. For the single-piece SPIs, no dehiscence was observed at 3 and 6 months follow-up. However, 2 abutment posts showed dehiscence at the 12 month follow-up. For the staged two-piece SPIs, 2 abutment posts showed dehiscence with implant base exposure at the 6 month follow-up. However; no statistically significant differences were found between the two SPI designs regarding both implant survival and dehiscence among all follow-up periods. <br/>Conclusion: Within the limitations of the current study, it could be concluded that both SPI designs were comparable from a clinical perspective; however, the single-piece SPI design could be considered superior to the two piece SPI design from a biomechanical perspective.
520 #3 - SUMMARY, ETC.
Summary, etc. تعد غرسات التايتانيوم المثبتة تحت السمحاق و التي تصمم خصيصا للمريض علاجا فعالا لمن يعانون من فقد كلي للأسنان مصاحب بضمور الفك السفلي. و قد ساهم التطور التكنولوجي في تسهيل عملية تصميم و تصنيع هذا النوع من الغرسات بشكل فعال و دقيق.<br/>تضمن الشق الأول من البحث اجراء تحليل العناصر المحدودة ثلاثي الأبعاد لمقارنة تصميمين مختلفين للغرسات المثبتة تحت السمحاق عن طريق تطبيق حمل مائل بزاوية 30 درجة على الجانب الأيمن لنموذج الفك السفلي و المثبت به غرسة تحت السمحاق مكونة من قطعة واحدة، ثم أعقبه تطبيق حمل مائل بزاوية 30 درجة على الجانب الأيسر لنفس النموذج و المثبت به غرسة تحت السمحاق مكونة من قطعتين. تم دراسة تأثير الأحمال على الغرسات و العظم المحيط بكل غرسة و البراغي المثبتة للغرسات، بالأضافة إلى تأثيرها على البِدْلَةٌ السِنِّيَّةٌ الثابتة.<br/>أظهرت نتائج تحليل العناصر المحدودة ثلاثي الأبعاد قيما متشابهة لكلا التصميمين من حيث أقصى جهد رئيسي عند العظم المحيط بهيكل الغرسة و جهد (von Mises) على براغي التثبيت، بالإضافة إلى قيم التشوه الشامل لبراغي التثبيت. و لكن، قيم جهد (von Mises) المسجلة لهيكل الغرسة في المحاكاة الثانية كانت ضعف القيم المسجلة لهيكل الغرسة في المحاكاة الأولى. <br/>في ظل محدوديات هذا البحث، يمكن استنتاج الآتي: أن التصميمين متشابهان من الناحية السريرية و لكن التصميم الاول (غرسة تحت السمحاق مكونة من قطعة واحدة) قد يفوق التصميم الثاني (غرسة تحت السمحاق مكونة من قطعتين) من الناحية الميكانيكية الحيوية.<br/>تضمن الشق الثاني من البحث تجربة سريرية عشوائية شارك فيها خمس مرضى (رجال)، حيث تم تثبيت غرسة تحت السمحاق مكونة من قطعة واحدة في جانب من الفك السفلي الضامر بالإضافة إلى غرسة تحت السمحاق مكونة من قطعتين في الجانب الآخر من الفك لكل مريض. لم تظهر النتائج فروق ذات دلائل إحصائية من حيث معدل بقاء الغرسات و كذلك الإنشقاق اللثوي.
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Issues CD Issues also as CD.
546 ## - LANGUAGE NOTE
Text Language Text in English and abstract in Arabic & English.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prosthodontics
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element الاستعاضة الصناعية
653 #1 - INDEX TERM--UNCONTROLLED
Uncontrolled term Subperiosteal implants
-- Dehiscence,Implant survival
-- Patient-specific implant
-- Finite element analysis
-- Bio-CAD modeling
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mahmoud Mokhtar El Far
Relator term thesis advisor.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Maha Wagdy El Kerdawy
Relator term thesis advisor.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Adel Hamdy Abo El Fetouh.
Relator term thesis advisor.
900 ## - Thesis Information
Grant date 01-01-2024
Supervisory body Mahmoud Mokhtar El Far
-- Maha Wagdy El Kerdawy
-- Adel Hamdy Abo El Fetouh
Universities Cairo University
Faculties Faculty of Dentistry
Department Department of Prosthodontics
905 ## - Cataloger and Reviser Names
Cataloger Name Shimaa
Reviser Names Eman Ghareb
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Edition 21
Suppress in OPAC No
Holdings
Source of classification or shelving scheme Home library Current library Date acquired Inventory number Full call number Barcode Date last seen Effective from Koha item type
Dewey Decimal Classification المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 17.01.2026 93151 Cai01.09.09.Ph.D.2024.Ma.I 01010110093151000 17.01.2026 17.01.2026 Thesis
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library