Incidence and predictors of cardiac implantable electronic device pocket infection / (Record no. 177899)

MARC details
000 -LEADER
fixed length control field 10245namaa22004451i 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GICUC
005 - أخر تعامل مع التسجيلة
control field 20260122133949.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 260120s2025 ua a|||frm||| 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloguing agency EG-GICUC
Language of cataloging eng
Transcribing agency EG-GICUC
Modifying agency EG-GICUC
Description conventions rda
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
Language code of summary or abstract eng
-- ara
049 ## - Acquisition Source
Acquisition Source Deposit
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 616.12
092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC)
Classification number 616.12
Edition number 21
097 ## - Degree
Degree M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Local Call Number Cai01.11.04.M.Sc.2025.Ho.I
100 0# - MAIN ENTRY--PERSONAL NAME
Authority record control number or standard number Hossam Farahat Ramzy Boshra,
Preparation preparation.
245 10 - TITLE STATEMENT
Title Incidence and predictors of cardiac implantable electronic device pocket infection /
Statement of responsibility, etc. by Hossam Farahat Ramzy Boshra ; Supervised Prof. Dr. Ahmed Mohamed Fahmy Eldamaty, Dr. Emmanuel Fares Aziz Fawzy, Dr. Mina Samy Halim Fawzy Youssef .
246 15 - VARYING FORM OF TITLE
Title proper/short title معدل حدوث وعوامل التنبؤ لعدوي جيب الاجهزة الالكترونية المزروعة فى القلب
264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Date of production, publication, distribution, manufacture, or copyright notice 2025.
300 ## - PHYSICAL DESCRIPTION
Extent 119 pages :
Other physical details illustrations ;
Dimensions 25 cm. +
Accompanying material CD.
336 ## - CONTENT TYPE
Content type term text
Source rda content
337 ## - MEDIA TYPE
Media type term Unmediated
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
Source rdacarrier
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.)-Cairo University, 2025
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography: pages 96-119.
520 #3 - SUMMARY, ETC.
Summary, etc. Background: Pacemakers (PM), implantable cardiac defibrillators (ICDs), and cardiac resynchronization <br/>therapy (CRT) devices are life-saving treatments for many cardiac conditions. Infection is one of the most <br/>serious complications of cardiac implantable electronic device (CIED )therapy and is associated with <br/>significant mortality, morbidity, and financial healthcare burden. In our study ,we aimed to determine the <br/>incidence of pocket infections and identify patients with a high risk for pocket infections <br/>Methods: This was aprospective observational Cohort longitudinal study that enrolled 200 patients <br/>(18 years or older ) who implanted cardiac electronic device in Cairo university hospitals form <br/>February 2024 to July 2024. All recruited patients underwent a full history, laboratory workup, 12-lead <br/>ECG, and echocardiography prior to device implantation.Device and procedural data were collected. <br/>All patients were followed after implantation for 6 months through 3 occasional visits(10 days -2 <br/>months -6 months) to assess: <br/> Systemic symptoms:fever,malaise and chills. <br/> Physical examination:erythema,swelling and driange. <br/>Results: All patients in both groups were given prophylactic antibiotics (2g of Ceftriaxone) as well as <br/>post-procedure antibiotics (Tavanic and Augmentin). Follow-up examinations after implantations <br/>revealed that 80% of patients developed infections within two months, but only 20% had infections <br/>after six months. Out of 200 patients, 10 had an infection related to their cardiovascular implantable <br/>electronic devices (CIEDs). The incidence of CIED infections among the studied patients was 5%. <br/>There is significant difference regarding age (p = 0.025), sex (p = 0.769), BMI (p = 0.192), and EF (p = <br/>0.024). Statistics indicated that diabetes mellitus (DM) had a significant difference with a p-value of <br/>0.041, heart failure (HF) had a p-value of 0.202, and chronic kidney disease (CKD) had a p-value of <br/>0.002 when compared to hypertension (p-value 0.202). Chronic obstructive pulmonary disease (COPD) <br/>(p-value 0.650) and immunocompromised status (p-value 0.251) were found to be comparable in both <br/>groups. In terms of laboratory results, creatinine levels (p-value 0.040), ALT (alanine <br/>aminotransferase) (p-value 0.003), and INR (international normalized ratio) (p-value 0.048) were <br/>significantly higher among infected patients compared to non-infected patients. The study found that <br/>the use of CRT-D devices (p = 0.001) and the number of leads (p = 0.001) were significantly higher in <br/>patients who developed infections. Additionally, the duration of the procedures (p = 0.013) was <br/>significantly longer for infected patients. Other significant findings included a higher percentage of <br/>complex procedures (p = 0.006), instances of device repositioning (p = 0.001), replacements (p = <br/>0.012), upgrades (p = 0.012), total procedures managed (TPM) (p = 0.038), and the incidence of <br/>hematomas (p = 0.001) among infected patients. <br/>Conclusion: The incidence of CIED infection in this study was 5%, Comorbidities were significantly <br/>more frequent among infected patients, specially diabetes, heart failure, and chronic kidney disease. <br/>while EF was significantly lower among infected patients. However, hypertension, COPD, and <br/>immunocompromised were higher among infected patients but without statistically significant <br/>difference. Infection was significantly greater for patients with CRT-D and those with higher number <br/>of leads. Moreover, longer procedure duration, and patients underwent previous procedures, <br/>replacement/upgrade, or reposition were significantly at high-risk of CIED infection.
520 #3 - SUMMARY, ETC.
Summary, etc. المقــدمـــــة<br/>تعد العدوي المرتبطة بالأجهزة الإلكترونية المزروعة في القلب من المضاعفات الخطيرة المرتبطة بالإجراءات التي تزيد من خطر الوفاة، وغالبًا ما تتطلب علاجها دخول المستشفى، وعادة ما تتطلب اعطاء مضادات حيوية و إزالة الجهاز المزروع احيانا. <br/>ومع ذلك، فإن عدد الإصابات المرتبطة بالأجهزة الإلكترونية المزروعة في القلب آخذ في الارتفاع مع زيادة عدد الأشخاص الذين يتلقون هذه الاجهزة. تم الإبلاغ عن معدل واسع من معدلات الإصابة. وقد وجدت التجارب السريرية الأخيرة متعددة المراكز أن معدلات الإصابة الإجمالية لمدة 12 شهرًا تبلغ حوالي 1%، في حين أفادت الدراسات السكانية الكبيرة عن معدلات تتراوح بين 0.7% و4.3%. يؤثر كل من نوع الجهاز ونوع الإجراء و وقت المتابعة على معدل الإصابة بـالعدوي، وكلها تحتاج إلى أخذها في الاعتبار عند مقارنة معدلات الإصابة.<br/>نظرًا لأن العدوى المرتبطة بالأجهزة الإلكترونية المزروعة في القلب ترتبط بنتائج أقل للمرضى، فإن تحديد المريض ونوعية الجهاز والعوامل الإجرائية التي تزيد من خطر العدوى أمر بالغ الأهمية لتطوير الاستراتيجيات السريرية التي تقلل من المخاطر.<br/>الهـــدف من الدراسة<br/>- تهدف هذه الدراسة إلى تحديد معدل الإصابة بالعدوى المرتبطة بالأجهزة الإلكترونية المزروعة في القلب وتحديد عوامل الخطورة لتوفير استراتيجيات وقائية كافية.<br/>المرضى وطرق البحث<br/>إجريت هذه الدراسة في قسم القلب والاوعية الدموية بمستشفى جامعة القاهرة من فبراير2024 حتى يوليو٢٠٢٤. وكان عدد المسجلين في الدراسة200 مريضا من الذين خضع لزراعة جهاز إلكتروني في القلب والذين استوفوا معايير الاشتمال لدينا.<br/>خضع جميع المشاركين في هذه الدراسة لأخذ التاريخ المرضى الكامل،والتقييم السريري والمختبري و الفحص السريري الكامل. التحاليل المختبرية الروتينية: تم إجراؤها وفقا لطرق المطبقة في قسم ومعامل الباثولوجيا الاكلينيكية بمستشفيات جامعة القاهرة وتضمنت:صورة دم شاملة وظائف كبد وكلي، وعوامل التجلط بالدم، بروتين سي التفاعلي، والصوديوم والبوتاسيوم بالدم، والهيموجلوبين السكري.<br/>التقييم: والذي يشمل: 3 زيارات مخطط لها (10 أيام - شهرين - 6 أشهر) لتقييم:<br/>- الأعراض الظاهرية: الحمى، الالام، والقشعريرة.<br/>- الفحص البدني: احمرار وتورم و ظهور تصريف صديدي من مكان الجرح. <br/>الاستنتاجات والتوصيات<br/>أظهرت نتائجنا معدل الإصابة الإجمالي المرتبط بـ الأجهزة الإلكترونية المزروعة في القلب كان منخفضًا (5%) ولكنه كان أعلى بالنسبة للأشخاص الأكثر عرضة لخطورة الإصابة بهذه العدوى.<br/> لقد حددنا العديد من عوامل المرتبطة بزيادة خطر الإصابة بالعدوى. يمكن أن تساعد معرفة هذه العوامل الأطباء على مناقشة مخاطر العدوى مع المرضى، وتحديد الأشخاص المعرضين لخطر الإصابة بشكل خاص، واتخاذ القرارات بشأن نوع الجهاز والتدخلات الوقائية.<br/>هناك الحاجة الى المزيد من الدراسات المتابعة واسعة النطاق ومتعددة المراكز وطويلة الأمد تركز على المرضى المعرضين لمخاطر عالية لتحديد عوامل الخطر الدقيقة للعدوى لتوفير استراتيجيات وقائية كافية.
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Issues CD Issues also as CD.
546 ## - LANGUAGE NOTE
Text Language Text in English and abstract in Arabic & English.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element cardiology
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element أمراض القلب
653 #1 - INDEX TERM--UNCONTROLLED
Uncontrolled term CIED
-- Infection
-- Incidence
-- Predictors
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Mohamed Fahmy Eldamaty
Relator term thesis advisor.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Emmanuel Fares Aziz Fawzy
Relator term thesis advisor.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mina Samy Halim Fawzy Youssef
Relator term thesis advisor.
900 ## - Thesis Information
Grant date 01-01-2025
Supervisory body Ahmed Mohamed Fahmy Eldamaty
-- Emmanuel Fares Aziz Fawzy
-- Mina Samy Halim Fawzy Youssef
Universities Cairo University
Faculties Faculty of Medicine
Department Department of Cardiology
905 ## - Cataloger and Reviser Names
Cataloger Name Shimaa
Reviser Names Eman Ghareb
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Edition 21
Suppress in OPAC No
Holdings
Source of classification or shelving scheme Home library Current library Date acquired Inventory number Full call number Barcode Date last seen Effective from Koha item type
Dewey Decimal Classification المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 20.01.2026 93201 Cai01.11.04.M.Sc.2025.Ho.I 01010110093201000 20.01.2026 20.01.2026 Thesis
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library