Assessment of peri-implant stress distribution in maxillary "All- on-4" prosthesis, fabricated on multi-unit angled abutments with Zirconia framework versus those with titanium framework : (رقم التسجيلة. 179898)
[ عرض عادي ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 06388namaa22004451i 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | EG-GICUC |
| 005 - أخر تعامل مع التسجيلة | |
| control field | 20260502221117.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 260502s2025 ua a|||frm||| 000 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Original cataloguing agency | EG-GICUC |
| Language of cataloging | eng |
| Transcribing agency | EG-GICUC |
| Modifying agency | EG-GICUC |
| Description conventions | rda |
| 041 0# - LANGUAGE CODE | |
| Language code of text/sound track or separate title | eng |
| Language code of summary or abstract | eng |
| -- | ara |
| 049 ## - Acquisition Source | |
| Acquisition Source | Deposit |
| 082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER | |
| Classification number | 617.692 |
| 092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC) | |
| Classification number | 617.692 |
| Edition number | 21 |
| 097 ## - Degree | |
| Degree | M.Sc |
| 099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
| Local Call Number | Cai01.09.09.M.Sc.2025.Ra.A |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Authority record control number or standard number | Raouf Rafick Raouf Rizkalla, |
| Preparation | preparation. |
| 245 10 - TITLE STATEMENT | |
| Title | Assessment of peri-implant stress distribution in maxillary "All- on-4" prosthesis, fabricated on multi-unit angled abutments with Zirconia framework versus those with titanium framework : |
| Remainder of title | A 3D Finite Element Analysis / |
| Statement of responsibility, etc. | by Raouf Rafick Raouf Rizkalla ; Supervisors Prof. Dr Ashraf Emil Eskandar, Prof. Dr. Nouran Abdel Nabi, Dr. Karim Fouda. |
| 246 15 - VARYING FORM OF TITLE | |
| Title proper/short title | توزيع الاجهاد حول الغرسة في حالات الكل علي اربعة في الفك العلوي المصنعة على دعامات بزاوية متعددة الوحدات مع إطار من الزركون مقابل تلك المزودة بإطار من التيتانيوم : |
| Remainder of title | تحليل العناصر المحدودة ثلاثي الابعاد |
| 264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
| Date of production, publication, distribution, manufacture, or copyright notice | 2025. |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 65 pages : |
| Other physical details | illustrations ; |
| Dimensions | 25 cm. + |
| Accompanying material | CD. |
| 336 ## - CONTENT TYPE | |
| Content type term | text |
| Source | rda content |
| 337 ## - MEDIA TYPE | |
| Media type term | Unmediated |
| Source | rdamedia |
| 338 ## - CARRIER TYPE | |
| Carrier type term | volume |
| Source | rdacarrier |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Thesis (M.Sc)-Cairo University, 2025. |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE | |
| Bibliography, etc. note | Bibliography: pages 54-63. |
| 520 #3 - SUMMARY, ETC. | |
| Summary, etc. | Aim: To evaluate peri-implant stresses generated using Finite Element Analysis (FEA)for <br/>titanium and zirconium frameworks for a maxillary all on four prostheses. <br/><br/>Material and methods: Three-dimensional finite element models of an edentulous maxilla <br/>restored with a prosthesis supported by 4 implants were reconstructed to carry out this analysis. The <br/>anterior implants were placed vertically in the lateral-canine area, whereas the posterior implants <br/>were placed with a 17-degree distal angulation at the second premolar area bilaterally. Multi-unit <br/>abutments were used for all implants. A framework of the first model made of zirconia was <br/>designed, while for the second model a titanium framework was planned. A 200 N force was <br/>applied to the central fossa of the first molar bilaterally. The Von Mises stresses were recorded on <br/>the framework, multiunit abutments and implants. <br/><br/> Results: The maximum Von Mises stress recorded on the prosthesis was similar between <br/>Zirconium and the Titanium framework. More significantly, the framework itself experiences a <br/>substantial difference, with the Zirconium framework showing a maximum stress of 131.88 MPa, <br/>while the Titanium framework's maximum stress was 95.272 Mpa. The maximum principal stresses <br/>on bone between the zirconium and titanium frameworks were nearly identical. The titanium <br/>framework showed a slightly higher value (11.025 MPa) than the zirconium (10.983 <br/>MPa).Regarding directional deformation both showed identical results. <br/>Conclusion: Both titanium and zirconium frameworks seem to be reliable treatment options <br/>for all on 4 concepts for restoring edentulous maxilla. Both materials showed similar pattern of <br/>transmission of stresses to the underlying implant and bone. Titanium showed more uniform stress <br/>distribution compared to zirconium within the framework. |
| 520 #3 - SUMMARY, ETC. | |
| Summary, etc. | قيمت هذه الدراسة الجهود حول الزراعات المتولدة باستخدام تحليل العناصر المحدودة لهيكل الزركونيوم والتيتانيوم للفك العلوي في تعويض الكل على اربعة. <br/>تم إجراء الدراسة باستخدام نموذج العناصر المحدودة ثلاثية الأبعاد في الفك العلوي الاسنان تم ترميمه باستخدام طرف تعويضي مدعوم بأربع غرسات تم إعادة بناءها لإجراء هذا التحليل تم وضع الغرسات الأمامية عموديًا في الناحيتين ما بين القاطع الجانبي والناب في حين تم وضع الغرسات الخلفية بزاوية 17 درجة بعيدة في منطقة الضاحك الثانية تم استخدام دعامات متعددة الوحدات لجميع عمليات الزرع تم تصميم إطار النموذج الأول المصنوع من التيتانيوم بينما النسبة للنموذج الثاني ، تم التخطيط لإطار من الزركونيوم وتظهر نتائجنا أنه تم تقييم إجهاد فون ميزس والضغط الأقصى والتشوه الاتجاهي في منطقة العظام المحيطة بالزرع تظهر النتائج التي توصلنا إليها أنه تم تقييم إجهاد فون ميزس والحد الأقصى من الإجهاد والتشوه الاتجاهي في منطقة العظام المحيطة بالزرع، تم تقييم إجهاد فون ميزس والإجهاد الأقصى والتشوه الاتجاهي في منطقة العظام المحيطة بالزرعة، وأظهرت التيتانيوم عن الزركونيوم أداء افضل على الإطار والطرف الاصطناعي المحتفظ بالمسمار، إلى الأساس العظام والزراعات المثبتة.<br/>وفقًا لمؤسستنا، يمكننا أن نقترح استخدام إما هياكل الزركونيوم أو التيتانيوم مع تعويض كلي شاملة لعديم الأسنان في الفك العلوي، وهو ما يعتبر خيارًا علاجيًا موثوقًا به |
| 530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
| Issues CD | Issues also as CD. |
| 546 ## - LANGUAGE NOTE | |
| Text Language | Text in English and abstract in Arabic & English. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Oral Implantology |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | زراعة الأسنان |
| 653 #1 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | All-on-4 |
| -- | abutment |
| -- | Zirconia |
| -- | titanium |
| -- | Von Mises stress |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Ashraf Emil Eskandar |
| Relator term | thesis advisor. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Nouran Abdel Nabi |
| Relator term | thesis advisor. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Karim Fouda |
| Relator term | thesis advisor. |
| 900 ## - Thesis Information | |
| Grant date | 01-01-2025 |
| Supervisory body | Ashraf Emil Eskandar |
| -- | Nouran Abdel Nabi |
| -- | Karim Fouda |
| Discussion body | Khaled Ahmed Abdeen |
| -- | Ramy Maher Sadek |
| Universities | Cairo University |
| Faculties | Faculty of Oral and Dental Medicine |
| Department | Department of Oral Implantology |
| 905 ## - Cataloger and Reviser Names | |
| Cataloger Name | Shimaa |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Thesis |
| Edition | 21 |
| Suppress in OPAC | No |
| Source of classification or shelving scheme | Home library | Current library | Date acquired | Inventory number | Full call number | Barcode | Date last seen | Effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 02.05.2026 | 93948 | Cai01.09.09.M.Sc.2025.Ra.A | 01010110093948000 | 02.05.2026 | 02.05.2026 | Thesis |