header

The role of high end multi detector CT in coronary imaging / (Record no. 38307)

MARC details
000 -LEADER
fixed length control field 01839cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223030617.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 120428s2012 ua h f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.31.M.Sc.2012.Ah.R
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Yehia Ahmed
245 14 - TITLE STATEMENT
Title The role of high end multi detector CT in coronary imaging /
Statement of responsibility, etc. Ahmed Yehia Ahme ; Supervised Seif Eldien Abaza Abdelmonaem , Mohamed Ali Salem
246 15 - VARYING FORM OF TITLE
Title proper/short title دور الاجيال الحديثه من الأشعه المقطعية متعددة المقاطع في تصوير الشرايين التاجيه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Yehia Ahme ,
Date of publication, distribution, etc. 2012
300 ## - PHYSICAL DESCRIPTION
Extent 122 P. :
Other physical details facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis
520 ## - SUMMARY, ETC.
Summary, etc. Prospective gating on 256-slice CT therefore provides a temporal resolution of 135 ms compared with 210 ms on 64-slice CT, the improvement in temporal resolution results in significantly improved image quality for all coronary vessels and reduction of the motion artifacts. The significant difference between 256-slice MDCT and 64-slice MDCT is that 256-slice MDCT requires only two image acquisition to be combined so reduces the stair-step artifact compared five to eight with 64 MDCT, so, the potential for stair-step artifacts is reduced with prospectively gated axial 256-slice CTCA even with higher heart rates
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term DSCT
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term MDCT
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term RCA
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Ali Salem ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Seif Eldien Abaza Abdelmonaem ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.31.M.Sc.2012.Ah.R 01010110057681000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.31.M.Sc.2012.Ah.R 01020110057681000 22.09.2023 CD - Rom 57681.CD
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library