Primary stability of implants inserted in osteoporotic patients by osteotome technique / (Record no. 49926)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02542cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031157.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 150319s2013 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.13.M.Sc.2013.Ra.P |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Rasha Mohammed Mohammed Ibrahim |
245 10 - TITLE STATEMENT | |
Title | Primary stability of implants inserted in osteoporotic patients by osteotome technique / |
Statement of responsibility, etc. | Rasha Mohammed Mohammed Ibrahim ; Supervised Maha Mohammed Hakam , Hesham Elhawary |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | الثبات المبدئى لغرسات الأسنان فى مرضى هشاشة العظام بإستخدام تقنية الطرق العظمى |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Rasha Mohammed Mohammed Ibrahim , |
Date of publication, distribution, etc. | 2013 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 87 Leaves : |
Other physical details | charts , facsimiles ; |
Dimensions | 30cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Objectives: Assessment of the primary stability and bone density around dental implants placed in the posterior maxilla of osteoporotic postmenauposal females using osteotome technique. Patients and Methods: Twelve posterior maxillary implants; installed in six post manepousal osteoporotic female were included in the study. Implant placement was performed by the osteotome technique. Pre-and postoperative Cone beam computerized tomography (CBCT) were used for measurement of bone density and osstell device was used for measurement of primary stability of implant. Results: There was a statistically significant increase in mean bone density at the buccal, palatal, mesial and distal surfaces of implant, while there was no statistically significant difference between the mean implant stability in the two directions (Bucco-Palatal (BP) and Mesio-Distal (MD)). Conclusion: Osteotome technique allows placement of implants in low density bone with acceptable primary stability and may slightly enhance bone density around implants placed in low density bone. Low bone density of osteoporotic female patients as quantified by DEXA does not persi affect the success rate of dental implants |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Implant |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Osteal device |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Osteotome |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Hesham Elhawary , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Maha Mohammed Hakam , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Aml |
Reviser | Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.13.M.Sc.2013.Ra.P | 01010110064807000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.13.M.Sc.2013.Ra.P | 01020110064807000 | 22.09.2023 | CD - Rom | 64807.CD |