Comprehensive fault location scheme for power transmission lines / (Record no. 50005)

MARC details
000 -LEADER
fixed length control field 02377cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031200.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 150323s2014 ua f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.07.M.Sc.2014.Ah.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Galal Ahmed ِAbdrabo
245 10 - TITLE STATEMENT
Title Comprehensive fault location scheme for power transmission lines /
Statement of responsibility, etc. Ahmed Galal Ahmed ; Supervised Essam Eldin AboElzahab , Doaa Khalil Ibrahim
246 15 - VARYING FORM OF TITLE
Title proper/short title اقتراح نظام متكامل لتحديد أماكن الأعطال على الخطوط الهوائية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Galal Ahmed Abdrabo ,
Date of publication, distribution, etc. 2014
300 ## - PHYSICAL DESCRIPTION
Extent 173 P. ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines
520 ## - SUMMARY, ETC.
Summary, etc. Accurate fault location on transmission lines is an important subject for researchers and network users to be assuring of continuity of supplying electric power, reducing outage time and reducing customer complaints. There are some factors affecting the process of fault location which are neglecting impact of fault resistance, supposing the parameters of the transmission line are fixed, false detecting and classifying of faults and neglecting the synchronization angle between both ends. For improving these negative effects, this thesis introduces a scheme for calculating transmission line parameters and extended to detect and classify both low and high impedance faults. This scheme also calculates low impedance fault location using unsynchronized measurements for voltage and current from both ends and also measures the accuracy of calculating low impedance fault location when the communication link between both ends fails by using the measurements of voltage and current at single end. This scheme is extended to calculate high impedance fault location using the measurements of voltage and current from both ends
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fault location
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term High impedance fault
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Low impedance fault
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Doaa Khalil Ibrahim ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam Eldin AboElzahab ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.07.M.Sc.2014.Ah.C 01010110064908000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.07.M.Sc.2014.Ah.C 01020110064908000 22.09.2023 CD - Rom 64908.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library