Influence of different cerec digitizing techniques on margin accuracy and internal fit of crowns / (Record no. 50314)

MARC details
000 -LEADER
fixed length control field 02929cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031210.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 150406s2013 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2013.Ah.I
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Roshdy Radwan
245 10 - TITLE STATEMENT
Title Influence of different cerec digitizing techniques on margin accuracy and internal fit of crowns /
Statement of responsibility, etc. Ahmed Roshdy Radwan ; Supervised Mohamed Labib Zamzam , Jylan Foad Elguindy
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير {uئإ٨ؤ}{uئإؤئ}{uئإأ٤}{uئإءإ}{uئإؤ٥} المختلفة {uئإؤئ}{uئإإ٠}{uئإإ٤}{uئإآ٤}{uئإء٢} {uئإ٨ؤ}{uئإؤئ}{uئإءإ}{uئإؤ٧}{uئإإ٤}{uئإئ٠} بجهاز {uئإ٨ؤ}{uئإؤئ}{uئإآ٤}رك {uئإأآ}{uئإإ٠}{uئإئ٠} {uئإء٩}{uئإؤ٧}{uئإ٩٤} الحو{uئإ٨ؤ}{uئإؤ١} {uئإإؤ}{uئإ٨ؤ}{uئإؤئ}تهئ {uئإ٨ؤ}{uئإؤئ}{uئإءء}{uئإ٨ؤ}{uئإء٧}{uئإإ٠}{uئإئ٠} {uئإؤئ}{uئإإ٠}{uئإ٩٨}{uئإئ٤}{uئإء٠}{uئإ٨إ}ن
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Roshdy Radwan ,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent 91 Leaves :
Other physical details charts , facsimiles , photographs ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. The aim of this study was to investigate the influence of the cerec different digitizing techniques on the marginal accuracy and internal fit of all-ceramic crowns using the cerec bluecam, 3D camera, Cerec inLab, and the cerec Ineos camera. A stainless steel die was constructed to simulate the average dimensions of a prepared upper first premolar with 6 mm height, 6{u00B0} convergence angle, and a shoulder finish line 1 mm in thickness. The die was scanned with the four-cerec scanners and the margin accuracy and internal fit were measured using the stereomicroscope. Repeated measures ANOVA were used to compare between the four techniques. The mean and standard deviation values of internal fit were 127 ± 25.4 æm, 127.6 ± 27 æm, 116.4 ± 17.5 æm and 113.8 ± 20.6 æm with 3D camera, Blue Cam, Ineos and Inlab, respectively, while the mean and standard deviation values of marginal accuracy were 68.8 ± 14.8 æm, 34 ± 2.2 æm, 84.8 ± 13.4 æm and 56.8 ± 14.1 æm with 3D camera, Blue cam, Ineos and Inlab, respectively. The different digitizing techniques Bluecam, 3D camera, Inlab, and Ineos had no influence on the internal fit, however the Scanner type influences the margin accuracy of all ceramic crowns
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Bluecam
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cerec
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cerec scanner
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Jylan Foad Elguindy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Labib Zamzam ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2013.Ah.I 01010110065182000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2013.Ah.I 01020110065182000 22.09.2023 CD - Rom 65182.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library