Evaluation of the peripheral dose and the conformity index for three stereotactic radiotherapy techniques; ARCS, noncoplanar fixed fields and intensity modulation/ (Record no. 51027)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 03886cam a2200349 a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | EG-GiCUC |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250223031231.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 150525s2014 ua h f m 000 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Original cataloging agency | EG-GiCUC |
| Language of cataloging | eng |
| Transcribing agency | EG-GiCUC |
| 041 0# - LANGUAGE CODE | |
| Language code of text/sound track or separate title | eng |
| 049 ## - LOCAL HOLDINGS (OCLC) | |
| Holding library | Deposite |
| 097 ## - Thesis Degree | |
| Thesis Level | Ph.D |
| 099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
| Classification number | Cai01.12.04.Ph.D.2014.Ha.E |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Hany Mohammed Abdelaal Ammar |
| 245 10 - TITLE STATEMENT | |
| Title | Evaluation of the peripheral dose and the conformity index for three stereotactic radiotherapy techniques; ARCS, noncoplanar fixed fields and intensity modulation/ |
| Statement of responsibility, etc. | Hany Mohammed Abdelaal Ammar ; Supervised Wafaa Mohamed Khalil , Mohammed Saad Zaghloul , Ehab Marouf Attalla , |
| 246 15 - VARYING FORM OF TITLE | |
| Title proper/short title | {uFE97}{uFED8}{uFEAA}{uFEF3}{uFEAE} ا{uئإؤئ}{uئإء٠}{uئإءإ}{uئإأآ}{uئإ٨إ}ت ا{uئإؤئ}{uئإإ٤}{uئإإ٨}{uئإء٨}{uئإؤ٤}{uئإأ٠}{uئإإء} و{uئإإ٣}{uئإأأ}{uئإ٨إ}{uئإإ٣}{uئإؤإ} ا{uئإؤئ}{uئإ٩٨}{uئإإإ}ا{uئإؤ٣}{uئإؤ٦} {uئإؤئ}{uئإ٩أ}{uئإئأ}ث {uئإأ٣}{uئإءإ}ق {uئإؤئ}{uئإإ٠}{uئإأأ}{uئإئأ}ج ا{uئإئآ}{uئإآ٧}{uئإأأ}اعى ا{uئإؤئ}{uئإء٠}{uئإءإ}ا{uئإء٣}{uئإئ٢} {uئإ٩آ}{uئإئأ}{uئإ٩آ}{uئإئ٢} ا{uئإئآ}{uئإ٩١}{uئإأأ}{uئإ٨إ}د ({uئإأ٣}{uئإءإ}{uئإئ٣}{uئإؤ٨}{uئإ٩٤} ا{uئإئآ}{uئإؤ٧}{uئإإإ}اس: {uئإأ٣}{uئإءإ}{uئإئ٣}{uئإؤ٨}{uئإ٩٤} ا{uئإؤئ}{uئإء٤}{uئإؤ٨}{uئإإإ}ل ا{uئإؤئ}{uئإ٩أ}{uئإ٨إ}{uئإ٩١}{uئإ٩٨}{uئإإء} {uئإإ٣}{uئإ٩٨}{uئإأأ}{uئإءء}دة ا{uئإؤئ}{uئإإ٤}{uئإآ٤}{uئإ٩٨}{uئإإإ}{uئإئ٣}{uئإ٨إ}ت وا{uئإؤئ}{uئإأأ}{uئإئأ}ج {uئإإ٣}{uئإ٩٨}{uئإؤ٠}{uئإئ٤}{uئإءإ} ا{uئإؤئ}{uئإآ٨}{uئإءء}{uئإإ٩} |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Cairo : |
| Name of publisher, distributor, etc. | Hany Mohammed Abdelaal Ammar , |
| Date of publication, distribution, etc. | 2014 |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 96 P. : |
| Other physical details | facsimiles ; |
| Dimensions | 25cm |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Thesis (Ph.D.) - Cairo University - Faculty of Science - Department of Biophysics |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | Purpose:The main aim of this work is to compare the conformity index and the peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using three stereotactic techniques; Arcs, noncoplanar fixed conformal fields(3DCRT) and intensity modulation(IMRT).Materials and Methods: Ten patients with different tumor sizes, shapes and localisations were selected for this study. Treatment plans were generated using three different techniques: Arcs, noncoplanar fixed fields and intensity modulation techniques. Treatment plans (Arcs, IMRT, 3DCRT) were created for the pediatric anthropomorphic phantom for different target sizes To measure and calculate the Peripheral Doses(PDs).Results: The IMRT technique shows the highest dose conformity, Arcs technique is the next homogeneity followed by 3DCRT.The results show that Arcs technique has the lowest volume of the body that received 2 Gy, IMRT is the next followed by 3DCRT and IMRT technique has the lowest volume of the body that received 5 Gy, Arcs technique is the next followed by 3DCRT. IMRT plan delivery time almost has two folded more than the two others techniques, and the arc the technique has the lowest estimated time compared to both IMRT and Conformal techniques. the IMRT technique has the highest values of PDs at distanc close to the PTV the next is Arcs technique followed by 3DCRT technique which has the lowest values |
| 530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
| Additional physical form available note | Issued also as CD |
| 653 #4 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Cofirmty Index |
| 653 #4 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Out-of-field doses |
| 653 #4 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Stereotactic Radiosurgery |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Ehab Marouf Attalla , |
| Relator term | |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Mohammed Saad Zaghloul , |
| Relator term | |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Wafaa Mohamed Khalil , |
| Relator term | |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
| 905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
| Cataloger | Aml |
| Reviser | Cataloger |
| 905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
| Cataloger | Nazla |
| Reviser | Revisor |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Thesis |
| Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.12.04.Ph.D.2014.Ha.E | 01010110065738000 | 22.09.2023 | Thesis | ||
| Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.12.04.Ph.D.2014.Ha.E | 01020110065738000 | 22.09.2023 | CD - Rom | 65738.CD |