Ultrasound assessment of lung aeration loss during a successful weaning trial predicts postextubation distress / (رقم التسجيلة. 53190)

تفاصيل مارك
000 -LEADER
fixed length control field 02939cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031332.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 151109s2015 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.09.M.Sc.2015.Ma.U
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mahmoud Ahmed Mosa Mohamed
245 10 - TITLE STATEMENT
Title Ultrasound assessment of lung aeration loss during a successful weaning trial predicts postextubation distress /
Statement of responsibility, etc. Mahmoud Ahmed Mosa Mohamed ; Supervised Tarek Samir Elgohary , Khaled Mahmoud Kamel , Wael Samy Gamal
246 15 - VARYING FORM OF TITLE
Title proper/short title {uFE98}{uFED8}{uFEF4}{uFEF4}م {uئإؤ٣}{uئإؤ٨}دان التهو{uئإئ٤}{uئإ٩٤} الر{uئإ٨أ}و{uئإئ٤}{uئإ٩٤} {uئإ٩٢}{uئإ٨إ}{uئإآ٤}{uئإ٩٨}{uئإء٨}دام المو{uئإء٠}{uئإ٨إ}ت {uئإؤ٣}وق الصو{uئإ٩٨}{uئإئ٤}{uئإ٩٤} على الرئة اثناء مرحلة الفطام الناجحة للتنبؤ بالاضطرابات التنفسية ما بعد نزع الانبوبة الحنجرية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mahmoud Ahmed Mosa Mohamed ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 133 P. :
Other physical details charts . facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Critical Care Medicine
520 ## - SUMMARY, ETC.
Summary, etc. Aim of work: To asses whether lung derecruitment during spontaneous breathing trial and postextubation assessed by lung ultrasound is predictive of postextubation distress. Results: Mean age was 56.66 ±6.36, 56% were males. Twelve patients failed the spontaneous breathing trial, 38 were extubated. 24 were definitively weaned (postextubation success group), and 14 suffered from postextubation distress. Loss of lung aeration at end of spontaneous breathing trial was marked in patients with postextubation distress, and increased from (11.57±2.24) to (14.93±2.23). ROC curve has an excellent predictive value for postextubation distress with area under the curve (AUC) 0.972 & cutoff value LUS {u2265}11 at the end of spontaneous breathing trial, with asensitivity of 100% & a specificity of 88%. ROC curve for difference in LUS between basal &end of trial showed an excellent predictive value for postextubation distress with sensitivity 100% & specificity 83% at cutoff value {u2265} 3 ( area under the curve = 0.91 ). Conclusion: Lung ultrasound determination of aeration changes during a successful spontaneous breathing trial accurately predict postextubation distress
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Lung ultrasound
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Mechanical ventilation
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Postextubation distress
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Khaled Mahmoud Kamel ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Tarek Samir Elgohary ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Wael Samy Gamal ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Soheir
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
المقتنيات
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.09.M.Sc.2015.Ma.U 01010110066690000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.09.M.Sc.2015.Ma.U 01020110066690000 22.09.2023 CD - Rom 66690.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library