header

Non invasive rapid accurate prediction of fluid responsiveness in critically Ill septic patient by echocardiography / (Record no. 58606)

MARC details
000 -LEADER
fixed length control field 02962cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031613.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 161114s2016 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.09.Ph.D.2016.Al.N
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Alsayed Rizk Rizk Saadah
245 10 - TITLE STATEMENT
Title Non invasive rapid accurate prediction of fluid responsiveness in critically Ill septic patient by echocardiography /
Statement of responsibility, etc. Alsayed Rizk Rizk Saadah ; Supervised Mohamed Sherif Mukhtar , Suzy Fawzy Mighaeil , Mervat Mohamed Khalaf
246 15 - VARYING FORM OF TITLE
Title proper/short title التوقع السريع الدقيق غير التداخلى لإستجابة مريض الصدمة الميكروبية للمحاليل الوريدية باستخدام الموجات الصوتية على القلب
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Alsayed Rizk Rizk Saadah ,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 111 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Critical Care Medicine
520 ## - SUMMARY, ETC.
Summary, etc. Abstract Introduction: Static measures fail to accurately predict fluid responsiveness(FR) in critically ill patient and have been recently replaced by dynamic parameters. Non invasive transthoracic echocardiographic (TTE) measurement of subaortic velocity time integral variations(xVTI) and respiratory variations of inferior vena caval diameter(xIVCD) are two dynamic measures to predict FR. Aim of the work: is to test whether non invasive dynamic measurement of xVTI and xIVCD using TTE ,can predict fluid responsiveness after a mini fluid challenge. Methodology: 40 spontaneously breathing Pa-ents with acute circulatory failure secondary to sep-c shock admi.ed to ICU over 6 months period, TTE measures VTI by Doppler on a 5 chamber apical view, and IVCD in subcostal view in M-mode . Then 500 ml 6% Hydroxyethyl starch (HES) were infused via a speci{uFB01}c venous line, The {uFB01}rst 100 ml were regularly infused over 1 min. , the remaining 400 ml were infused at a constant rate over 14min.TTE reassessments were performed a8er the first minute and after completion of infusion. Results: Patients were Classified into two groups, responders or non responders according to FR, Fluid replacement remains the corner stone for resuscitation of patients with acute circulatory failure due to septic shock. Neverthless up to one half of patients of septic shock do not gain benefit from fluid therapy, moreover it can be counterproductive in many of them .
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fluid responsiveness
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Heart
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Septic shock
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mervat Mohamed Khalaf ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Sherif Mukhtar ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Suzy Fawzy Mighaeil ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Soheir
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.09.Ph.D.2016.Al.N 01010110070145000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.09.Ph.D.2016.Al.N 01020110070145000 22.09.2023 CD - Rom 70145.CD
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library