Comparative analysis of stresses induced in internal and external hex implant abutment connections under axial and off axial loading / (رقم التسجيلة. 58651)

تفاصيل مارك
000 -LEADER
fixed length control field 02361cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031614.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 161116s2016 ua o f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2016.Ma.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mahmoud Hamed Mahmoud Hamed
245 10 - TITLE STATEMENT
Title Comparative analysis of stresses induced in internal and external hex implant abutment connections under axial and off axial loading /
Statement of responsibility, etc. Mahmoud Hamed Mahmoud Hamed ; Supervised Lamia Sayed Kheiralla , Gihan Abdulhady Elnaggar
246 15 - VARYING FORM OF TITLE
Title proper/short title تحليل مقارن لإختلافات تركيزات الإجهاد فى غرسات الاسنان ذات الوصلات السداسية الداخلية و الخارجية تحت التحميل المحورى و الغير المحورى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mahmoud Hamed Mahmoud Hamed ,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 73 P. :
Other physical details photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. This study was conducted to evaluate the stresses transmitted to implant supporting structures using implants with internal hex and implants with external hex type of implant abutment attachment, under 2 different conditions of loading which are axial loading and off-axial loading. In this study 6 epoxy resin casts were constructed from a readymade silicon mould. Where the 12 implant fixtures (13 mm. length and 3.75 mm. in diameter) were fixed in the place of the maxillary second molar bilaterally, then an abutment was mounted on each fixture, and a crown was constructed and cemented on each implant. Results showed that concerning the type of connection external hex connection resulted into higher strain values than that of the internal hex connection, and concerning the type of loading off-axial loading resulted into higher strain values than that of the axial loading
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term External hex implant
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Off axial loading
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Stresses induced
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Gihan Abdulhady Elnaggar ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Lamia Sayed Kheiralla ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
المقتنيات
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2016.Ma.C 01010110070259000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2016.Ma.C 01020110070259000 22.09.2023 CD - Rom 70259.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library