header

Validity and reliability of six-minute walk test in modrate obese subject / (Record no. 60996)

MARC details
000 -LEADER
fixed length control field 02779cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031726.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170527s2016 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.21.09.M.Sc.2016.Mo.V
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Ali Mohamed Ismaiel
245 10 - TITLE STATEMENT
Title Validity and reliability of six-minute walk test in modrate obese subject /
Statement of responsibility, etc. Mohamed Ali Mohamed Ismaiel ; Supervised Amir Mohamed Saleh , Yaser Mohamed Aneis , Hany Farid Eid Morsy Elsisi
246 15 - VARYING FORM OF TITLE
Title proper/short title مدى كفاءة و فاعلية اختبار ست دقائق مشى لدى الأشخاص متوسطى السمنة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Ali Mohamed Ismaiel ,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 108 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Basic Science
520 ## - SUMMARY, ETC.
Summary, etc. Obesity is a serious worldwide medical condition, considered by some researchers as one of the most serious public health problems of the 21st century. The 6 minute walk test (6MWT) is a practical, simple test that measures the maximal distance walked in 6 minute. It can be used to evaluate functional capacity for human performance. To investigate the criterion related validity and intra rater reliability of 6MWT in relation to cardiopulmonary exercise testing (CPX) in assessing functional capacity in moderate obese subject. Forty subject from both sex (20 males and 20 females), with BMI between 30 to 35 kg/m2 their ages ranged from 20 to 30 years old. All subjects were undergoing both 6MWT twice and CPX one time. Results: there was a significant positive relationship between 6 minute walk test distance (6MWD) and VO2 in moderate obese subject, with rs=0.88, p and P-value =0.0001 and high test-retest reliability in the study group (ICC=0.96, with 95% CI 0.93-0.98) A significant difference in the 6MWD between the males and females participants was observed in this study. The males had a significantly higher mean 6MWD (545.25±34.81m vs. 489.5±45.12 m) than the females counterparts. Six minute walk test may be considered as criterion related valid and intra rater reliable test to measure functional capacity in relation to cardiopulmonary exercise testing in moderate obese subject
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cardiopulmonary exercise testing
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Obesity
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Six minute walk test
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amir Mohamed Saleh ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hany Farid Eid Morsy Elsisi ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Yaser Mohamed Aneis ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.21.09.M.Sc.2016.Mo.V 01010110071740000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.21.09.M.Sc.2016.Mo.V 01020110071740000 22.09.2023 CD - Rom 71740.CD
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library