Validity and reliability of six-minute walk test in modrate obese subject / (Record no. 60996)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02779cam a2200349 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031726.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 170527s2016 ua dh f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.21.09.M.Sc.2016.Mo.V |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Mohamed Ali Mohamed Ismaiel |
245 10 - TITLE STATEMENT | |
Title | Validity and reliability of six-minute walk test in modrate obese subject / |
Statement of responsibility, etc. | Mohamed Ali Mohamed Ismaiel ; Supervised Amir Mohamed Saleh , Yaser Mohamed Aneis , Hany Farid Eid Morsy Elsisi |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | مدى كفاءة و فاعلية اختبار ست دقائق مشى لدى الأشخاص متوسطى السمنة |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Mohamed Ali Mohamed Ismaiel , |
Date of publication, distribution, etc. | 2016 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 108 P. : |
Other physical details | charts , facsimiles ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Physical Therapy - Department of Basic Science |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Obesity is a serious worldwide medical condition, considered by some researchers as one of the most serious public health problems of the 21st century. The 6 minute walk test (6MWT) is a practical, simple test that measures the maximal distance walked in 6 minute. It can be used to evaluate functional capacity for human performance. To investigate the criterion related validity and intra rater reliability of 6MWT in relation to cardiopulmonary exercise testing (CPX) in assessing functional capacity in moderate obese subject. Forty subject from both sex (20 males and 20 females), with BMI between 30 to 35 kg/m2 their ages ranged from 20 to 30 years old. All subjects were undergoing both 6MWT twice and CPX one time. Results: there was a significant positive relationship between 6 minute walk test distance (6MWD) and VO2 in moderate obese subject, with rs=0.88, p and P-value =0.0001 and high test-retest reliability in the study group (ICC=0.96, with 95% CI 0.93-0.98) A significant difference in the 6MWD between the males and females participants was observed in this study. The males had a significantly higher mean 6MWD (545.25±34.81m vs. 489.5±45.12 m) than the females counterparts. Six minute walk test may be considered as criterion related valid and intra rater reliable test to measure functional capacity in relation to cardiopulmonary exercise testing in moderate obese subject |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Cardiopulmonary exercise testing |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Obesity |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Six minute walk test |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Amir Mohamed Saleh , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Hany Farid Eid Morsy Elsisi , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Yaser Mohamed Aneis , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Samia |
Reviser | Cataloger |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.21.09.M.Sc.2016.Mo.V | 01010110071740000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.21.09.M.Sc.2016.Mo.V | 01020110071740000 | 22.09.2023 | CD - Rom | 71740.CD |