Accuracy of cone beam computed tomography (CBCT) versus digital periapical radiography by photostimulated phosphor in detection of dental root fractures : (Record no. 61382)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03637cam a2200337 a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | EG-GiCUC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20250223031738.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 170620s2016 ua dho f m 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloging agency | EG-GiCUC |
Language of cataloging | eng |
Transcribing agency | EG-GiCUC |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
049 ## - LOCAL HOLDINGS (OCLC) | |
Holding library | Deposite |
097 ## - Thesis Degree | |
Thesis Level | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Classification number | Cai01.09.13.M.Sc.2016.Ha.A |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Hanan Omar Mohammed AboAlrejal |
245 10 - TITLE STATEMENT | |
Title | Accuracy of cone beam computed tomography (CBCT) versus digital periapical radiography by photostimulated phosphor in detection of dental root fractures : |
Remainder of title | Diagnostic study / |
Statement of responsibility, etc. | Hanan Omar Mohammed Abo-Alrejal ; Supervised Hoda Abdelkader Saleh , Omniya Mahmoud Abu El- Dahab |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | دقة التصوير المقطعي بالحاسوب مخروطي الشعاع مقابل التصوير الرقمي حول الذروي بواسطة الفسفور المستحث ضوئياً في اكتشاف كسور جذور الأسنان : |
Remainder of title | دراسة تشخيصية |
260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
Place of publication, distribution, etc. | Cairo : |
Name of publisher, distributor, etc. | Hanan Omar Mohammed AboAlrejal , |
Date of publication, distribution, etc. | 2016 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 98 P. : |
Other physical details | charts , facsimiles , photographs ; |
Dimensions | 25cm |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery |
520 ## - SUMMARY, ETC. | |
Summary, etc. | The sample was divided randomly into 2 equal groups; the first group consisted of 33 teeth representing a control group without RFs and the second group contained 33 teeth that were subjected to RFs created by mechanical force, the fractured teeth were 11 VRFs, 11 HRFs and 11 oblique RFs. All teeth were mounted on dry human mandibles.All the samples were radiographed with two different imaging modalities (CBCT and PSP). The data was analyzed by three observers (Professor of Oral and Maxillofacial Radiology, Faculty of Oral and Dental Medicine, Cairo University, Lecturer of Oral and Maxillofacial Radiology, Faculty of Oral and Dental Medicine, Cairo University and the third one is a master candidate of Oral and Maxillofacial Radiology, Faculty of Oral and Dental Medicine, Cairo University). The observers evaluated the presence and the direction of RFs using five points score; (1) definitely absent, (2) probably absent, (3) unsure, (4) probably present and (5) definitely present. For the diagnostic accuracy of the two modalities used in this study, the statistical analysis was performed using Kappa test, sensitivity, specificity and likelihood ratio.Comparing the two groups throughout the whole study, the sensitivity and specificity of the CBCT (75.27% and 91.39% respectively) were higher than PSP plate (68.81% and 73.11% respectively) regarding the presence and absence of RF.The sensitivity of CBCT in detection of vertical, horizontal and oblique RFs (66.67%, 68.62% and 62.32% respectively) was greater than PSP plate (51.84%, 64.77% and 52.37% respectively).The specificity of CBCT in detection of vertical, horizontal and oblique RFs (96.78%, 93.54% and 90.34% respectively) was greater than PSP plate (94.85%, 86.01% and 81.54% respectively). The positive and negative likelihood ratio was better for CBCT when compared to PSP plate which indicated that the CBCT was more accurate than PSP plate regarding the presence and types of root fracture |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Additional physical form available note | Issued also as CD |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Accuracy of cone beam computed tomography (CBCT) |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Photostimulated phosphor |
653 #4 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Versus digital periapical radiography |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Hoda Abdelkader Saleh , |
Relator term | |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Omniya Mahmoud AbuelDahab , |
Relator term | |
856 ## - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Enas |
Reviser | Cataloger |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
Cataloger | Nazla |
Reviser | Revisor |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.09.13.M.Sc.2016.Ha.A | 01010110071907000 | 22.09.2023 | Thesis | ||
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.09.13.M.Sc.2016.Ha.A | 01020110071907000 | 22.09.2023 | CD - Rom | 71907.CD |