header

Accuracy of cone beam computed tomography (CBCT) versus digital periapical radiography by photostimulated phosphor in detection of dental root fractures : (Record no. 61382)

MARC details
000 -LEADER
fixed length control field 03637cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031738.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170620s2016 ua dho f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.13.M.Sc.2016.Ha.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Hanan Omar Mohammed AboAlrejal
245 10 - TITLE STATEMENT
Title Accuracy of cone beam computed tomography (CBCT) versus digital periapical radiography by photostimulated phosphor in detection of dental root fractures :
Remainder of title Diagnostic study /
Statement of responsibility, etc. Hanan Omar Mohammed Abo-Alrejal ; Supervised Hoda Abdelkader Saleh , Omniya Mahmoud Abu El- Dahab
246 15 - VARYING FORM OF TITLE
Title proper/short title دقة التصوير المقطعي بالحاسوب مخروطي الشعاع مقابل التصوير الرقمي حول الذروي بواسطة الفسفور المستحث ضوئياً في اكتشاف كسور جذور الأسنان :
Remainder of title دراسة تشخيصية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Hanan Omar Mohammed AboAlrejal ,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 98 P. :
Other physical details charts , facsimiles , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery
520 ## - SUMMARY, ETC.
Summary, etc. The sample was divided randomly into 2 equal groups; the first group consisted of 33 teeth representing a control group without RFs and the second group contained 33 teeth that were subjected to RFs created by mechanical force, the fractured teeth were 11 VRFs, 11 HRFs and 11 oblique RFs. All teeth were mounted on dry human mandibles.All the samples were radiographed with two different imaging modalities (CBCT and PSP). The data was analyzed by three observers (Professor of Oral and Maxillofacial Radiology, Faculty of Oral and Dental Medicine, Cairo University, Lecturer of Oral and Maxillofacial Radiology, Faculty of Oral and Dental Medicine, Cairo University and the third one is a master candidate of Oral and Maxillofacial Radiology, Faculty of Oral and Dental Medicine, Cairo University). The observers evaluated the presence and the direction of RFs using five points score; (1) definitely absent, (2) probably absent, (3) unsure, (4) probably present and (5) definitely present. For the diagnostic accuracy of the two modalities used in this study, the statistical analysis was performed using Kappa test, sensitivity, specificity and likelihood ratio.Comparing the two groups throughout the whole study, the sensitivity and specificity of the CBCT (75.27% and 91.39% respectively) were higher than PSP plate (68.81% and 73.11% respectively) regarding the presence and absence of RF.The sensitivity of CBCT in detection of vertical, horizontal and oblique RFs (66.67%, 68.62% and 62.32% respectively) was greater than PSP plate (51.84%, 64.77% and 52.37% respectively).The specificity of CBCT in detection of vertical, horizontal and oblique RFs (96.78%, 93.54% and 90.34% respectively) was greater than PSP plate (94.85%, 86.01% and 81.54% respectively). The positive and negative likelihood ratio was better for CBCT when compared to PSP plate which indicated that the CBCT was more accurate than PSP plate regarding the presence and types of root fracture
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Accuracy of cone beam computed tomography (CBCT)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Photostimulated phosphor
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Versus digital periapical radiography
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hoda Abdelkader Saleh ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Omniya Mahmoud AbuelDahab ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Enas
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.13.M.Sc.2016.Ha.A 01010110071907000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.13.M.Sc.2016.Ha.A 01020110071907000 22.09.2023 CD - Rom 71907.CD
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library