The effect of manufacturing technique, storage and sterilization on the accuracy of computer aided implant surgical guides : (رقم التسجيلة. 62875)

تفاصيل مارك
000 -LEADER
fixed length control field 02977cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031823.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171011s2016 ua do f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2016.Ma.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mahetab Hamdi Abdelfatah
245 14 - TITLE STATEMENT
Title The effect of manufacturing technique, storage and sterilization on the accuracy of computer aided implant surgical guides :
Remainder of title An Invitro study =تأثير طرق الصناعة المختلفة التخزين و التعقيم على دقة الادلة الجراحية للغرسات بمساعدة الكمبيوتر : دراسة معمليه /
Statement of responsibility, etc. Mahetab Hamdi Abdelfatah ; Supervised Ashraf Abdelmonem Amer , Amr Hosny Elkhadem
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير طرق الصناعة المختلفة ، التخزين و التعقيم على دقة الادلة الجراحية للغرسات بمساعدة الكمبيوتر :
Remainder of title دراسة معمليه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mahetab Hamdi Abdelfatah ,
Date of publication, distribution, etc. 2016
300 ## - PHYSICAL DESCRIPTION
Extent 109 :
Other physical details charts , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. This invitro study was designed to compare the effect of four manufacturing techniques, storage, chemical sterilization and autoclaving on accuracy of computer guided surgical guides. An impression for class III Kennedy classification partially edentulous case was made and poured into epoxy resin to construct a cast. The cast was laser scanned and a surgical guide was designed by the Blue sky software for implant planning. Four techniques were used for manufacturing which were SLS, milling, SLA and FDM. Measuring accuracy were done in three terms; evaluation of sleeve hole tolerance, guide adaptation and accuracy of sleeve angle. The sleeve hole tolerance was evaluated by special customized metal cylinders of different diameters where each diameter was used to evaluate its fit inside the sleeve hole. For the microgap photos were captured by digital microscope and then analyzed by image J software. Regarding angular deviation, laser scanning of the surgical guide with special customized metal cylinders both were sealed on the model was done then evaluating of angular deviation was carried by blue sky..The accuracy was measured in five phases after 24 hour of manufacturing, one week storage, two week storage, chemical sterilization and autoclaving. All results were tabulated and analyzed to reach conclusion
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Accuracy
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Manufacturing technique
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Storage and sterilization
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amr Hosny Elkhadem ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ashraf Abdelmonem Amer ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Enas
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
المقتنيات
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2016.Ma.E 01010110072710000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2016.Ma.E 01020110072710000 22.09.2023 CD - Rom 72710.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library