Assessment of intraocular pressure using ocular response analyzer and goldman applanation tonometry before and after penetrating keratoplasty (PKP) / (Record no. 62924)

MARC details
000 -LEADER
fixed length control field 03346cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031825.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171014s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.24.M.Sc.2017.Am.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Amr Mohamed Abdelaziz Wassef
245 10 - TITLE STATEMENT
Title Assessment of intraocular pressure using ocular response analyzer and goldman applanation tonometry before and after penetrating keratoplasty (PKP) /
Statement of responsibility, etc. Amr Mohamed Abdelaziz Wassef ; Supervised Khaled Abdeljalil Mansour , Soheir Mohamed Essmat , Heba Magdy Ahmed
246 15 - VARYING FORM OF TITLE
Title proper/short title قياس ضغط العين باستخدام جهاز تحليل إستجابة العين وجهاز جولدمان لقياس ضغط العين عن طريق تسطيح القرنية قبل وبعد زرع القرنية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Amr Mohamed Abdelaziz Wassef ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 73 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology
520 ## - SUMMARY, ETC.
Summary, etc. To compare the obtainability and values of IOP measurements by Goldmann Applanation Tonometry (GAT) and Ocular Response Analyzer (ORA) before and after penetrating keratoplasty (PKP) testing the degree of their agreement and the impact of corneal biomechanical factors on IOP measurement. Patients and Methods The study is a comparative prospective study in which patients scheduled for penetrating keratoplasty (PKP) undergo intraocular pressure measurement (IOP) using the Ocular Response Analyzer (ORA) then the Goldman applanation tonometer (GAT) one day before surgery to be repeated one month after their surgery. Results Forty patients undergoing PKP were enrolled in the study, 28 males (70%) and 12 females 30%). The mean age of patients involved is 42.8 ± 15.4, ranging between 9 and 75 years. Obtainability of ORA (92.5% of the patients) was significantly higher than GAT (60%) postoperatively (p<0.001), while no significant difference was elicited preoperatively. The mean cornea corrected IOP (IOPcc) was significantly higher than GAT and Goldmann related IOP (IOPg) both pre and postoperatively. In addition, both mean IOPcc and GAT postoperatively (19.2 ± 8.31, 15.65 ± 6.99 mmhg respectively) were significantly higher than their preoperative values (14.44 ± 7.03, 11.78 ± 4.55 mmhg respectively). Strong correlations existed between GAT and ORA measurements both pre and postoperatively. As expected the level of agreement between GAT and IOPg was higher than IOPcc. Conclusion ORA has proven to be superior to GAT in the ability to obtain reliable IOP measurements post PKP. IOPcc measurements also prooved to be relavant, independent on corneal biomechanical factors (CH and CRF) but judging the accuracy of its values needs further large scale studies.
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Intraocular pressure
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Ocular Response Analyzer
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Penetrating Keratoplasty
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Heba Magdy Ahmed ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Khaled Abdeljalil Mansour ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Soheir Mohamed Essmat ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.24.M.Sc.2017.Am.A 01010110072995000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.24.M.Sc.2017.Am.A 01020110072995000 22.09.2023 CD - Rom 72995.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library