header

Optimal design of forced draft counter flow cooling towers / (Record no. 64125)

MARC details
000 -LEADER
fixed length control field 01996cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031900.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219s2017 ua eh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.11.M.Sc.2017.Le.O
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Leena Omar Mohamed Elsayed Abdelsalam
245 10 - TITLE STATEMENT
Title Optimal design of forced draft counter flow cooling towers /
Statement of responsibility, etc. Leena Omar Mohamed Elsayed Abdelsalam ; Supervised Essam E. Khalil , Kamal Ahmed Abed , Gamal Elhariry
246 15 - VARYING FORM OF TITLE
Title proper/short title التصميم الأمثل لأبراج التبريد ذات السحب القصرى و السريان المضاد
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Leena Omar Mohamed Elsayed Abdelsalam ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 73 P. :
Other physical details facsimiles , plans ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering
520 ## - SUMMARY, ETC.
Summary, etc. The study aims at analytically determining the optimum conditions for a counter flow forced draft cooling tower taking the minimization of the operating cost as an objective. First a mathematical model that effectively describes the counter flow cooling tower was selected and the programming was carried out with MATLAB software. Then a parametric analysis was conducted in which the effect of parameters: air and water mass flow rate(s), inlet water temperature was investigated on performance parameters. Finally different case studies were examined in order to select optimum conditions which resulted in minimizing the operating cost
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Counter flow cooling towers
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Forced draft
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Parametric analysis
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam E. Khalil ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Gamal Elhariry ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Kamal Ahmed Abed ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.11.M.Sc.2017.Le.O 01010110073822000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.11.M.Sc.2017.Le.O 01020110073822000 22.09.2023 CD - Rom 73822.CD
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg