Modeling of air quality and flow regimes in pharmaceutical clean rooms / (Record no. 65237)

MARC details
000 -LEADER
fixed length control field 02465cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031937.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180303s2017 ua ho f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.11.M.Sc.2017.He.M
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Hesham Mohammed Metwally
245 10 - TITLE STATEMENT
Title Modeling of air quality and flow regimes in pharmaceutical clean rooms /
Statement of responsibility, etc. Hesham Mohammed Metwally ; Supervised Essam E. Khalil Hassan khalil , Taher Mohamed Aboudeif , Ahmed Mahmoud Abouzaid
246 15 - VARYING FORM OF TITLE
Title proper/short title نمذجة جودة الهواء و نهج السريان داخل المختبرات الصيدلانيه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Hesham Mohammed Metwally ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 100 P. :
Other physical details facsimiles , photographs ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Mechanical Power Engineering
520 ## - SUMMARY, ETC.
Summary, etc. Pharmaceutical laboratory of preparation and production is a clean space that must be under the classification of ISO. This clean space is affected by the particle concentration per cubic meter of volume. Particles concentration is a major concern in many industrial activities where it is affected by many factors. Examples of these factors are particle size, space activity and particle generating flux. The identification of all these factors helps to evaluate the required mass flow rate and air velocity. The cost of HVAC systems for the clean area is about 50 times the cost of HVAC systems for the same room at different application. The required mass flow rate to achieve a higher ISO classification is increasing the sizing of HVAC equipment and its cost. The present study will be divided into two steps. First, calculation of the space mass flow rate and air velocity will be done to achieve the required space ISO classification. Second, modeling of the airflow regimes will be done using computational fluid dynamics (CFD) utilizing the ANSYS 17.2 software
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Air velocity profile
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Particle concentration
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Pharmaceutical laboratory
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Mahmoud Abouzaid ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Essam Eldin Khalil Hassan khalil ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Taher Mohamed Aboudeif ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.11.M.Sc.2017.He.M 01010110074441000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.11.M.Sc.2017.He.M 01020110074441000 22.09.2023 CD - Rom 74441.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library