Correlation between amount of fluid used during elliptical phacoemulsification using stop and chop technique and ultrasound time and power used / (Record no. 65367)

MARC details
000 -LEADER
fixed length control field 03107cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031941.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180310s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.24.M.Sc.2017.Ne.C
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nermeen Shawky Botros Ghaly
245 10 - TITLE STATEMENT
Title Correlation between amount of fluid used during elliptical phacoemulsification using stop and chop technique and ultrasound time and power used /
Statement of responsibility, etc. Nermeen Shawky Botros Ghaly ; Supervised Yehia Salaheldin Mostafa , Ahmed Sherief , Lamiaa Samy
246 15 - VARYING FORM OF TITLE
Title proper/short title العلاقة بين كمية السائل المستخدم أثناء عملية إزالة المياة البيضاء بإستخدام جهاز الموجات فوق الصوتية بالتقنية الأهليلجيه و كمية الطاقة المستخدمة و زمن التفتيت
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Nermeen Shawky Botros Ghaly ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 104 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology
520 ## - SUMMARY, ETC.
Summary, etc. Objectives: The aim of this study is to correlate between amounts of fluid used during elliptical phacoemulsification using stop and chop technique and the time and power used. Methodology: The study was done on 117 eyes which had different cataract grades. Disinfection and draping of the surgical field was done. Then temporal clear cornea 2.2mm incision was done. Afterwards Two 20 gauge paracentesis was done followed by capsulorhexis. Then Stop and chop nuclear fragmentation using vertical chopping technique took place. It was followed by bimanual irrigation aspiration. Foldable IOL was implanted. Amount of fluid used during phaco and I/A, separately, was documented. Besides cataract grade, phaco power and time used were recorded. The effective phacoemulsification time (EPT) using EFX, denoting the amount of ultrasound delivered not only by transversal motion but also by longitudinal motion, was analyzed. The EFX was roughly the EPT with a specific coefficient for the transversal movement expressed in seconds Results: There is correlation between the amount of fluid used during phacoemulsification and I/A. There is correlation between nuclear grade, total fluid used, average phaco power, u/s time and EFX. These correlations are statistically significant. Conclusion: Preoperatively adjusting amount of fluid used based on cataract grade helped improve overall efficiency by reducing the amount of energy and reducing overall phaco time, so we can achieve minimal effect on the corneal endothelium
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fluid used during Phaco & I/A
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Phaco parameters
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Phacoemulsification
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmed Sherief ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Lamiaa Samy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Yehia Salaheldin Mostafa ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.24.M.Sc.2017.Ne.C 01010110074561000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.24.M.Sc.2017.Ne.C 01020110074561000 22.09.2023 CD - Rom 74561.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library