Effect of laser or ultrasonic application on pneumatic crown removal / (Record no. 66291)

MARC details
000 -LEADER
fixed length control field 03281cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032008.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180523s2013 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2013.Ah.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Samir Awad Elsayed
245 10 - TITLE STATEMENT
Title Effect of laser or ultrasonic application on pneumatic crown removal /
Statement of responsibility, etc. Ahmed Samir Awad Elsayed ; Supervised Maged Elhakim , Maha Ahmed Taymour
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير تطبيق الذبذبات فوق الصوتية أو الليزر لنزع التيجان بإستخدام نازع التيجان الهوائي
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Samir Awad Elsayed ,
Date of publication, distribution, etc. 2013
300 ## - PHYSICAL DESCRIPTION
Extent 75 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. 6 This study investigated the in vitro effect of ultrasonic instrumentation or laser application on the removal resistance of crowns cemented with two different cements (glass ionomer and zinc phosphate) removed by pneumatic crown remover after thermocycling and cyclic loading Thirty extracted human maxillary first molars were used Teeth selected with average crown length 7.5mm and 7mm width. The molars were mounted in 3/4-inch diameter plastic cylinders filled with epoxy. With the use of ahorizontal milling device the crown of each tooth was machined to receive a full-coverage cast restoration. Teeth were prepared with taper of approximately 8 degrees .The preparation is adjusted to be 5mm length and 6mm in width. Chamfered cervical margins were established until their axial walls were 0.5 mm away from the external outline. Crowns were cast in nickel chromium alloy using conventional lost wax casting technique. Castings in each subgroup were luted with two cements: zinc phosphate (spofa) Glass ionomer (kromoglass). The specimens were subjected to thermal aging simulating the oral conditions with mean low-temperature point was 6.60C (range 0{u2013}36 0C, median 5.00C) then they were subjected to mechanical aging (20000 cycles). Cylinders holding prepared teeth are placed in fixation device and pneumatic crown remover is used to remove the crowns. Timing is calculated in fractions of second . Data was summarized using mean and standard deviation for quantitative variables. Comparisons between groups were done using unpaired t test when comparing 2 groups and analysis of variance (ANOVA) with multiple comparisons post hoc test when comparing more than 2 groups. P-values less than 0.05 were considered as statistically significant and given star while P-values less than 0.01were considered as statistically highly significant and given two stars
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Laser
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Pneumatic crown remova
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Ultrasonic application
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Maged Elhakim ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Maha Ahmed Taymour ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2013.Ah.E 01010110075089000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2013.Ah.E 01020110075089000 22.09.2023 CD - Rom 75089.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library