The role of 3D tomographic ultrasound imaging and doppler studies in diagnosis of morbidly adherent placenta / (Record no. 67179)

MARC details
000 -LEADER
fixed length control field 03675cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032035.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180828s2017 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.31.M.Sc.2017.Al.R
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Alaa Sobhi Abdelghani Abdelwahab
245 14 - TITLE STATEMENT
Title The role of 3D tomographic ultrasound imaging and doppler studies in diagnosis of morbidly adherent placenta /
Statement of responsibility, etc. Alaa Sobhi Abdelghani Abdelwahab ; Supervised Soha Talaat Hamed , Eman Faker Kamal , Hisham Mamdouh Haggag
246 15 - VARYING FORM OF TITLE
Title proper/short title دور الموجات فوق الصوتية ثلاثية الابعاد متعددة المقاطع و الدوبلر في تشخيص المشيمة الملتصقة
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Alaa Sobhi Abdelghani Abdelwahab ,
Date of publication, distribution, etc. 2017
300 ## - PHYSICAL DESCRIPTION
Extent 139 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Radio-diagnosis
520 ## - SUMMARY, ETC.
Summary, etc. Background: Morbidly adherent placenta is abnormal placental adherence or invasion of the myometrium or extra uterine structures. It is increasing in incidence because of increasing number of cesarean sections and is one of the main causes of excessive postpartum hemorrhage. The application of Tomographic Ultrasound Imaging is used for the visualization of the depth of placental invasion. Preoperative ultrasound diagnosis allows appropriate preoperative preparations and the decision to leave the placenta untouched to avoid a probable fatal outcome for the patient. Objective: To detect the accuracy of the three-dimensional tomographic imaging (3D TUI) &Doppler in the diagnosis of morbidly adherent placenta (MAP). Patient and method: Twenty three pregnant women at {u2265}34 week's gestation with suspected MAP were included in this prospective study. Two dimensional (2D) trans-abdominal gray-scale and color Doppler ultrasound scan was performed for the subjects to confirm the gestational age, placental location, and findings suggestive of MAP, followed by the 3D power Doppler and then the 3D TUI to confirm the diagnosis of MAP. Intraoperative findings and histopathology results of removed uteri in cases managed by emergency hysterectomy were compared with preoperative sonographic findings to detect the accuracy of the 3D TUI in the diagnosis of MAP Results: The 3D TUI increased the accuracy and predictive values of the diagnostic criteria of MAP compared with the 2D gray scale. The sensitivity and negative predictive value (NPV) (75% and 78.57%, respectively) of myometrial thinning to detect difficult placental separation and considerable intraoperative blood loss in cases of MAP using the 2D gray scale was increased to 100% and 100%, respectively, using the 3D TUI . In addition, the accuracy 91.30% of crowded vessels over the peripheral sub- placental zone to detect difficult placental separation by 2D Doppler for the detection of emergency hysterectomy in cases of MAP using the 3D power Doppler was increased to 100% respectively, using the 3D power Doppler. Conclusion: The 3D TUI is a useful adjunctive tool to the 3D power Doppler or color Doppler to refine the diagnosis of MAP
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Doppler
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Morbidly adherent placenta
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term TUI
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Eman Faker Kamal ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hisham Mamdouh Haggag ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Soha Talaat Hamed ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.31.M.Sc.2017.Al.R 01010110075599000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.31.M.Sc.2017.Al.R 01020110075599000 22.09.2023 CD - Rom 75599.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library