Tissue doppler versus conventional echocardiography and serum cardiac troponin i in assessment of myocardial performance in perinatally asphyxiated full term neonates / (Record no. 68665)

MARC details
000 -LEADER
fixed length control field 03442cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032120.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 181124s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.28.M.Sc.2018.Do.T
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Doaa Mostafa Mohammed Refaay Elshemy
245 10 - TITLE STATEMENT
Title Tissue doppler versus conventional echocardiography and serum cardiac troponin i in assessment of myocardial performance in perinatally asphyxiated full term neonates /
Statement of responsibility, etc. Doaa Mostafa Mohammed Refaay Elshemy ; Supervised Mohamed Saad Elbaz , Walaa Alsharany Abuelhamed , Alaa Eldin Adel Sobeih
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم أداء عضلة القلب بواسطة الدوبلر النسيجى بالمقارنة بالموجات الصوتية الاعتيادية على القلب و التروبونين فى الأطفال الذين يعانون من الاختناق الوليدى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Doaa Mostafa Mohammed Refaay Elshemy ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 162 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Pediatrics
520 ## - SUMMARY, ETC.
Summary, etc. Introduction: Myocardial functions are affected by the stress conditions such as shock and hypoxia. Signs of myocardial dysfunction depend on the severity of the injury. Hypoxia in the asphyxiated newborns often causes myocardial dysfunction. Objectives: The current study is designed to assess myocardial performance of full-term infants with perinatal asphyxia using tissue Doppler imaging (TDI) and to correlate it with serum cardiac troponin I( cTnI) concentrations. Material and methods: Twenty asphyxiated full-term newborn were consecutively enrolled in this study and another cross-matched twenty normal newborns as control group. All patients were subjected to measurement Serum cTnI concentrations that were measured between 12 and 24 hours of life. Conventional two-dimensional Doppler echocardiography and TDI were done during the {uFB01}rst 72 hours of life. Results: Cases with HIE had significant elevation of cTnI (p= 0.007), and serum troponin was significantly elevated among non-survivors newborns (p=0.008). Also lower pH and higher cTnI were significantly associated with higher risk of mortality among neonates with HIE (p=0.036 and p=0.038) respectively. There was significant difference between cases and controls as regards LV-DD in both pulsed wave and TDI (p<0.001); while the RV-DD showed no statistically difference between both groups .In our study, analysis of cutoff values, sensitivity, specificity, and area under ROC curves for dif»ferent markers of myocardial dysfunction revealed that serum cTnI, LV-E'/A', IVS-E'/A' and RV-E'/A' showed the highest diagnostic/prognostic values in predicting mortality in asphyxiated infants compared to other parameters (sensitivity 88.9%, 88.9%, 88.9%, 77.8% and specificity 72.7%, 45.5%, 63.6% and 54.5%respectively)
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Echocardiography
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Perinatal asphyxia
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Tissue Doppler imaging
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Alaa Eldin Adel Sobeih ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Saad Elbaz ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Walaa Alsharany Abuelhamed ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.28.M.Sc.2018.Do.T 01010110076395000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.28.M.Sc.2018.Do.T 01020110076395000 22.09.2023 CD - Rom 76395.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library