Verification and measurement of the inverted obtuse side cut angle of corneal flap in patients undergoing Femtosecond laser in-situ keratomilusis using FS 200 kHZ system and the acute side cut angle using conventional microkeratome / (Record no. 70799)

MARC details
000 -LEADER
fixed length control field 02772cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032225.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190313s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.24.M.Sc.2018.Sa.V
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Sarah Taha Abdallah
245 10 - TITLE STATEMENT
Title Verification and measurement of the inverted obtuse side cut angle of corneal flap in patients undergoing Femtosecond laser in-situ keratomilusis using FS 200 kHZ system and the acute side cut angle using conventional microkeratome /
Statement of responsibility, etc. Sarah Taha Abdallah ; Supervised Cherif Hussein Zaazuo , Mohamed Hassan Hosny , Sarah Akram Azzam
246 15 - VARYING FORM OF TITLE
Title proper/short title قياس زاوية قطع القرنية في المرضى الذين يتم إجراء تصحيح لهم بتقنيه الفيمتوليزك وزاوية قطع رفرف القرنية الحاده في المرضى تصحيح الابصار باستخدام مبضع القرنية المجهري
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Sarah Taha Abdallah ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 81 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology
520 ## - SUMMARY, ETC.
Summary, etc. Background: Advancements in laser technology have not only shortened the time needed to cut femtosecond LASIK flaps ,but also enabled refractive surgeons to customize side-cut architecture ,so the inverted side-cut flaps result in less dry eye , better wound healing and improved apposition of severed nerves because of the biomechanical superiority of the inverted side- cut with femtosecond laser flaps .In addition, the flap settless into a pocket when it is reseated, providing additional stability , so there is significant differences in wound healing.Purpose : To compare the intended versus the achieved side cut angle of corneal flaps in femtosecond laser in-situ keratomileusis versus the conventional microkeratome. Methods : A prospective non randomized interventional clinical trial was conducted on 40 eyes ( 20 eyes per group ) between Dec 2017 and August 2018. Heidelberg anterior segment OCT was done for the patients,The high resolution images obtained with the Heidelberg anterior segment OCT show the layers of the cornea in details and aid in the assessment of side cut angle 2 weeks postoperativly
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Femtosecond LASIK
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Femtosecond-assisted laser in-situ keratomileusis
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Flap side cut angle
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Cherif Hussein Zaazuo ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Hassan Hosny ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.24.M.Sc.2018.Sa.V 01010110077409000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.24.M.Sc.2018.Sa.V 01020110077409000 22.09.2023 CD - Rom 77409.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library