Verification and measurement of the inverted obtuse side cut angle of corneal flap in patients undergoing Femtosecond laser in-situ keratomilusis using FS 200 kHZ system and the acute side cut angle using conventional microkeratome / (Record no. 70799)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02772cam a2200337 a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | EG-GiCUC |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250223032225.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 190313s2018 ua dh f m 000 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Original cataloging agency | EG-GiCUC |
| Language of cataloging | eng |
| Transcribing agency | EG-GiCUC |
| 041 0# - LANGUAGE CODE | |
| Language code of text/sound track or separate title | eng |
| 049 ## - LOCAL HOLDINGS (OCLC) | |
| Holding library | Deposite |
| 097 ## - Thesis Degree | |
| Thesis Level | M.Sc |
| 099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
| Classification number | Cai01.11.24.M.Sc.2018.Sa.V |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Sarah Taha Abdallah |
| 245 10 - TITLE STATEMENT | |
| Title | Verification and measurement of the inverted obtuse side cut angle of corneal flap in patients undergoing Femtosecond laser in-situ keratomilusis using FS 200 kHZ system and the acute side cut angle using conventional microkeratome / |
| Statement of responsibility, etc. | Sarah Taha Abdallah ; Supervised Cherif Hussein Zaazuo , Mohamed Hassan Hosny , Sarah Akram Azzam |
| 246 15 - VARYING FORM OF TITLE | |
| Title proper/short title | قياس زاوية قطع القرنية في المرضى الذين يتم إجراء تصحيح لهم بتقنيه الفيمتوليزك وزاوية قطع رفرف القرنية الحاده في المرضى تصحيح الابصار باستخدام مبضع القرنية المجهري |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Cairo : |
| Name of publisher, distributor, etc. | Sarah Taha Abdallah , |
| Date of publication, distribution, etc. | 2018 |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 81 P. : |
| Other physical details | charts , facsimiles ; |
| Dimensions | 25cm |
| 502 ## - DISSERTATION NOTE | |
| Dissertation note | Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | Background: Advancements in laser technology have not only shortened the time needed to cut femtosecond LASIK flaps ,but also enabled refractive surgeons to customize side-cut architecture ,so the inverted side-cut flaps result in less dry eye , better wound healing and improved apposition of severed nerves because of the biomechanical superiority of the inverted side- cut with femtosecond laser flaps .In addition, the flap settless into a pocket when it is reseated, providing additional stability , so there is significant differences in wound healing.Purpose : To compare the intended versus the achieved side cut angle of corneal flaps in femtosecond laser in-situ keratomileusis versus the conventional microkeratome. Methods : A prospective non randomized interventional clinical trial was conducted on 40 eyes ( 20 eyes per group ) between Dec 2017 and August 2018. Heidelberg anterior segment OCT was done for the patients,The high resolution images obtained with the Heidelberg anterior segment OCT show the layers of the cornea in details and aid in the assessment of side cut angle 2 weeks postoperativly |
| 530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
| Additional physical form available note | Issued also as CD |
| 653 #4 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Femtosecond LASIK |
| 653 #4 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Femtosecond-assisted laser in-situ keratomileusis |
| 653 #4 - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | Flap side cut angle |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Cherif Hussein Zaazuo , |
| Relator term | |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Mohamed Hassan Hosny , |
| Relator term | |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a> |
| 905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
| Cataloger | Nazla |
| Reviser | Revisor |
| 905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) | |
| Cataloger | Shimaa |
| Reviser | Cataloger |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Thesis |
| Source of classification or shelving scheme | Not for loan | Home library | Current library | Date acquired | Full call number | Barcode | Date last seen | Koha item type | Copy number |
|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 11.02.2024 | Cai01.11.24.M.Sc.2018.Sa.V | 01010110077409000 | 22.09.2023 | Thesis | ||
| Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | مخـــزن الرســائل الجـــامعية - البدروم | 11.02.2024 | Cai01.11.24.M.Sc.2018.Sa.V | 01020110077409000 | 22.09.2023 | CD - Rom | 77409.CD |