Reliability of fluorescent camera and caries detection dye versus the visual tactile method in determining caries excavation endpoint using microbiological assessment : (رقم التسجيلة. 72015)

تفاصيل مارك
000 -LEADER
fixed length control field 02706cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032302.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190518s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.03.M.Sc.2018.Mo.R
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Mohamed Sabry Mohamed
245 10 - TITLE STATEMENT
Title Reliability of fluorescent camera and caries detection dye versus the visual tactile method in determining caries excavation endpoint using microbiological assessment :
Remainder of title Randomized clinical trial /
Statement of responsibility, etc. Mohamed Mohamed Sabry Mohamed ; Supervisd Mohamed Riad Farid , Rasha Ra'fat Abdelaziz
246 15 - VARYING FORM OF TITLE
Title proper/short title دقة الأعتماد على الكاميرا الفلورسنت و صبغ كشف التسوس ضد طريقة اللمس البصري في تحديد نقطة نهاية حفر التسوس بواسطة التقييم الميكروبيولوجي :
Remainder of title تقنية أكلينيكيه عشوائيه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Mohamed Sabry Mohamed ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 54 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Operative Dentistry
520 ## - SUMMARY, ETC.
Summary, etc. Aim: to assess the reliability of the fluorescence camera or caries detection dye versus visual tactile method in caries excavation using bacteriological assessment method. Materials and Methods: 60 carious lesions in 20 paticipant (3 in each paticipant) was chosen in this study. In each participant , there had been 3 carious lesions ; the excavation end point of one cavity was determined using visual tactile method. The two other cavities were inspected using the fluorescent camera and caries detector dye (CDD) to determine the excavation endpoint respectively. Dentine samples from the three cavities were collected before and after caries excavation for the bacteriological assessment. Results: the Visual tactile method showed lowest reduction in the bacterial count followed by Caries detector dye followed by the highest reduction for Fluorescent camera with a statistically significant difference between each other{u2019}s. Conclusion: the light induced fluorescent intraoral camera is more effective in removing infected dentin and in reaching the excavation endpoint
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Caries removal end point
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Excavation end point
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Fluorescent camera
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Riad Farid ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Rasha Ra'fat Abdelaziz ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
المقتنيات
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.03.M.Sc.2018.Mo.R 01010110078148000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.03.M.Sc.2018.Mo.R 01020110078148000 22.09.2023 CD - Rom 78148.CD
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library